ABB Baile INICT13A Discontinued: How One Communication Card Can Stall INFI 90 Data Flow
2026-09-11

ABB Bailey INICT13A Discontinued: How One Communication Card Can Stall INFI 90 Data Flow

In power plants and chemical facilities running Bailey INFI 90 systems, there is a failure mode that operators dread more than a controller trip: the moment every temperature, pressure, and flow reading on the operator station freezes or goes blank — not because the process has stopped, but because one card deep inside the cabinet has stopped talking.

That card is the INICT13A. In ABB Bailey INFI 90 architecture, it serves as the Infi-Net to Computer Transfer module — the bridge between the control network and the plant's supervisory computers. The original unit is no longer in production. ABB's recommended successor is the SPICT13A, but the installed base of legacy systems continues to generate replacement demand.

INFI 90 Data Flow — Where the INICT13A Sits Field Devices Sensors / Actuators I/O Modules IMASI / IMDSI Series Controllers IMMFP01 / MFP Series INFI-NET CONTROL BUS — 1 Mbps, Dual Redundant INICT13A Transfer Module Operator Station / HMI If INICT13A fails → operator loses all real-time data, trends, and alarms

What the INICT13A Actually Does

To understand why a single card can stall an entire data flow, you need to understand the INFI 90 architecture.

In an INFI 90 system, field controllers — such as the IMMFP01 — execute the actual control logic. They read temperature, pressure, valve position, and other process variables through I/O modules, then run PID loops and logic sequences. But that data stays on the INFI-NET control bus, speaking Bailey's proprietary protocol at 1 Mbps over dual redundant coaxial or fiber links.

The INICT13A sits between INFI-NET and the supervisory layer. On one side, it connects to the control network. On the other, it provides a SCSI high-speed parallel port or RS-232 serial interface to the operator station, historian, or plant computer. It packages process data for upload and passes operator commands back down to the controllers.

Without this card, the INFI 90 system loses its window into the process. The controllers keep running, the I/O keeps scanning, but the operator sees nothing — no real-time values, no trends, no alarms. For a plant that relies on central monitoring, that is equivalent to losing control.

Key Specifications (Summary)

Parameter Specification
Model INICT13A (also referenced as INICT13 / ICT13A)
System Family ABB Bailey INFI 90 / Network 90 / Symphony
Function Infi-Net to Computer Transfer Module
Network Side INFI-NET, 1 Mbps, dual redundant links supported
Host Interface SCSI high-speed parallel / RS-232 serial
Power Backplane supplied, 5 VDC / ±15 VDC
Installation INFI 90 standard rack slot, hot-swap capable
Lifecycle Status Discontinued; successor: SPICT13A

After the Discontinuation: The 2026 Sourcing Reality

The INICT13A discontinuation did not happen overnight. As ABB migrated the Bailey product line toward Symphony Plus and System 800xA, the INICT13A was classified as obsolete. The official migration path points to the SPICT13A, designed for the Symphony Plus platform.

But a substantial installed base of INFI 90 systems remains in service across power generation, refining, and water treatment. Many of these systems were commissioned in the 2000s and are still running today. The result is a persistent supply-demand mismatch: the original manufacturer has stopped production, but installed systems still need replacements.

Today's supply comes from three channels: new surplus stock, professionally tested refurbished units, and de-installed modules from retired systems. Industry sources note that the secondary market for INFI 90 hardware is tightening year by year, making verification of incoming spares a discipline in itself.

Common Failure Modes and Diagnostics

Based on field experience, INICT13A-related communication faults typically present in three forms:

  • Complete loss of data on the operator station — module is fully offline. Check backplane power (5 VDC) and rack connector seating.
  • Intermittent data dropouts or sluggish updates — bus loading too high, oxidized connectors, or poor SCSI cable shielding and grounding.
  • Frequent timeouts and retransmissions — incorrect SW4 DIP switch settings. ABB documentation notes that SW4 positions 6, 7, and 8 must remain open when using the SCSI interface.

Replace or Migrate: Two Paths Forward in 2026

When an INICT13A fails or spare stock runs dry, plants typically face a choice between two strategies.

Path One: Maintain the status quo with like-for-like replacement. This suits facilities that do not plan a full system upgrade in the near term. The main challenge is sourcing. New surplus INICT13A inventory is limited, and overseas lead times can exceed 40 days. For a 24/7 production line, that wait is often unacceptable.

Path Two: Accelerate system migration. Gradually upgrade the INFI 90 platform to Symphony Plus or System 800xA. ABB's recommended migration uses the SPICT13A as a transitional replacement. A full migration involves controllers, I/O, and the operator layer, so investment and outage windows must be planned carefully.

In practice, many plants adopt a hybrid approach: retain existing controllers and I/O, replace only the discontinued or high-failure-rate communication and operator-layer modules. INICT13A replacement often becomes the first concrete step in that strategy.

One recent example illustrates the stakes. A 25+ MW biomass energy plant in North America operated a Bailey INFI 90 powerhouse Balance of Plant control system alongside a GE Mark III turbine control system. The facility upgraded to a Rockwell PlantPAx DCS to achieve unified control and reduce maintenance costs. The upgrade was completed with a total plant outage limited to three weeks — a timeline that required pre-outage control logic testing and careful coordination with plant personnel. The project demonstrates that migration is feasible, but requires disciplined planning.

FAQ

Is the INICT13A still available for purchase?

The original manufacturer has discontinued it, but channel inventory still circulates, including new surplus and professionally tested refurbished units. Availability fluctuates, so confirm stock status early.

Can the INICT13A and SPICT13A be used interchangeably?

The SPICT13A is ABB's recommended successor, designed for the Symphony Plus platform. When used in an INFI 90 system, hardware revision and system compatibility must be verified. A small-scale test before full deployment is strongly advised.

Will an INICT13A failure bring down the entire DCS?

The controller and I/O layer usually continue running the process. However, the supervisory interface goes completely dark — operators cannot see real-time data or issue remote commands. For processes that depend on central monitoring, this is effectively a loss of control.

Are there third-party alternatives?

Some third-party suppliers offer compatible protocol gateway modules. However, compatibility with the existing INFI-NET bus, data refresh rate, and redundancy failover must be carefully evaluated. Validate on non-critical loops first.

Parts & Technical Support

Manager: Leonia

Email: sales@mvme.cn

WhatsApp: +86 180 3017 5807

Recommended Spare Parts — ABB Bailey & Related Systems

Brand Model Description
ABB Bailey INICT13A Infi-Net to Computer Transfer Module
ABB Bailey SPICT13A Successor communication transfer module
ABB Bailey IMMFP01 Multi-function processor module
ABB Bailey INNIS01 Infi-Net to I/O interface module
ABB Bailey IMASI23 Analog input module, 16-channel
ABB Bailey IMDSI22 Digital input module, 16-channel
ABB Bailey IMDAO03 Analog output module
ABB Bailey IMDSO14 Digital output module
ABB Bailey INICT03A Computer transfer module, earlier version
ABB Bailey NTMP01 Network interface module
ABB Bailey NTAI05 Analog input termination unit
ABB Bailey NTDI01 Digital input termination unit
ABB Bailey PHARPSFAN03000 Cooling fan module for INFI 90 racks
ABB Bailey SPBRC400 Bridge controller module
ABB Bailey SPNPM22 Network processing module

<< How to Reduce Nuisance Alarms and Prevent Unnecessary Trips in Turbine Monitoring Systems

>> How Can Buyers Evaluate Suppliers in a Low-Price Market?

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.