Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>YOKOGAWA>Yokogawa AVR10D-A22010 | Vnet Router for Vnet/IP and VL Net
Yokogawa AVR10D-A22010 | Vnet Router for Vnet/IP and VL Net

Yokogawa AVR10D-A22010 | Vnet Router for Vnet/IP and VL Net Item NO.: 2928425

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Yokogawa AVR10D-A22010 | Vnet Router for Vnet/IP and VL Net
Item NO. 2928425
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category YOKOGAWA
Brand YOKOGAWA
Creation Time 2026-10-30

Yokogawa AVR10D-A22010 | Moore Automation
Yokogawa

Yokogawa · CENTUM VP network routing

Yokogawa AVR10D-A22010 | Vnet Router for Vnet/IP and VL Net

100 Mbit/s Vnet/IP side · 10 Mbit/s V/VL net side · Dual power execution

01

Product Summary

Yokogawa AVR10D-A22010 is a dual-power Vnet Router that connects a Vnet/IP control network to a V net or VL net segment. The selected A2 code identifies the dual-redundant VL net execution while the remaining suffixes retain the dual-power and 100–120 V AC selection.

Across the network boundary, Yokogawa AVR10D-A22010 uses 100 Mbit/s full-duplex Vnet/IP and a 10 Mbit/s V net or VL net path. Ethernet switch connections, coaxial termination and station addressing must be planned as two different media systems joined by one router.

For commissioning, Yokogawa AVR10D-A22010 should be verified first on each network side and then end to end. Power-feed status, Vnet/IP links, V net or VL net termination and representative station communication form the practical acceptance record.

02

Specification Details

Brand
Yokogawa
Model
AVR10D-A22010
Product Name
Vnet Router
Country
Japan
System
CENTUM VP
Network A
Vnet/IP
Vnet/IP speed
100 Mbit/s full duplex
Network B
V net or VL net
V/VL net speed
10 Mbit/s
Selected execution
Dual-redundant VL net
Power execution
Dual-redundant
Supply
100–120 V AC
Vnet/IP cable
UTP CAT5e or better; 100 m segment
V/VL connector
BNC coaxial
Mounting
19-inch rack
Approximate weight
5.8 kg
03

Communication and Connectivity

Yokogawa AVR10D-A22010 joins two control-network media, so each side must be designed, labelled and tested independently before routing is accepted. The check therefore follows the complete path from interface ownership and physical media to addressing, link state and end-to-end communication.

Define the Vnet/IP Side

Record switch ports, Ethernet addresses and cable route for both Vnet/IP paths. Record the role of each physical port or fibre end before wiring, so cable labels and the saved network plan describe the same path.

Terminate the VL Net Side

Verify BNC connectors, coaxial route and required termination before connecting stations. Keep media type, connector condition, termination and route limits as installation checks; a software change cannot correct a damaged or mismatched physical link.

Test End-to-End Traffic

Confirm communication from representative stations across Yokogawa AVR10D-A22010, not only local link indicators. Acceptance should prove both local link indication and end-to-end traffic, with the tested path saved against the complete article record.

04

Diagnostics and Protection

Fault isolation for Yokogawa AVR10D-A22010 starts with dual power, then separates Vnet/IP from the V net or VL net segment. The diagnostic method preserves first-fault evidence, separates the affected layers and verifies the corrected path before the alarm is considered resolved.

Compare Both Power Feeds

Measure and label both supplies so degraded redundancy remains visible. Capture the first LED pattern, system message and affected path before resetting anything, because later alarms may be consequences rather than the cause.

Capture Link Evidence

Record which Ethernet and coaxial indicators changed first before resetting the router. Isolate power, network and field-bus branches one at a time so protection or communication evidence is not lost by changing several conditions together.

Retest the Corrected Path

After cable or setting changes, verify local links and end-to-end station communication. After correction, repeat the failed path test and document the restored state instead of accepting only a cleared alarm indication.

05

Questions & Answers

01

What does the A2 portion of Yokogawa AVR10D-A22010 select?

For Yokogawa AVR10D-A22010, A2 identifies the dual-redundant VL net execution. Keep that network selection with the Vnet/IP addressing and the BNC coaxial layout when planning a replacement.

02

Why are both Ethernet and coaxial checks needed for Yokogawa AVR10D-A22010?

The 100 Mbit/s Vnet/IP side and 10 Mbit/s V net or VL net side of Yokogawa AVR10D-A22010 use different media, connectors and termination rules. A healthy side does not prove the other side is correct.

03

What causes unstable communication through Yokogawa AVR10D-A22010?

Inspect BNC termination and coax condition on the V net or VL net side, Ethernet cable and switch status on the Vnet/IP side, and confirm that no duplicate network settings have been introduced around Yokogawa AVR10D-A22010.

04

What information should accompany an enquiry for Yokogawa AVR10D-A22010?

Include the exact Yokogawa AVR10D-A22010, existing network types, supply voltage, connected station count, observed indicators and diagnostic messages so the requested router is evaluated in its actual network boundary.

05

How should Yokogawa AVR10D-A22010 be checked before it bridges the two control networks?

Verify the complete Yokogawa AVR10D-A22010 suffix, Vnet/IP side, V net or VL net selection, supply execution and cable interfaces. Both network definitions must match the saved system architecture.

06

Why can one side of Yokogawa AVR10D-A22010 communicate while the other side does not?

The Vnet/IP and V net or VL net sides use different physical and network conditions. Check link status, cable type, termination, addresses and routing configuration independently for Yokogawa AVR10D-A22010.

06

Obsolete Parts Support

Moore Automation

https://www.mvme.cn/

Moore Automation accepts enquiries for legacy and current industrial automation parts when the complete article can be identified.

Available technical records and replacement context can accompany the request, without claiming a guaranteed successor or inventory position.

Legacy identityOriginal codes stay explicit.
Context reviewInstalled-system details can follow.
Record searchAvailable documents are coordinated.
Careful wordingNo unverified replacement claim.
07

Suggested Products

Bently Nevada2300/25-00
GEIC200UDD240
GEDS200TCQAG1B
GEIC200CHS005
GEDS200FCSAG2A
GEDS200FCSAG1A
Rockwell Automation20G11TD740JN0NNNNN
GEIC200UDR040
GEDS200PANAH1A
Rockwell Automation1756-RM2XT
ABBPM564-RP-AC
GEIC630MDL351
MotorolaMVME147-012A
GE ExcitationIS400TCASH1A
GEIS200HFPAG2A
Rockwell Automation2198-E2055-ERS
GEIC3600LIBA1
ABB Robotics3HAC022286-001
GEIC200ALG265
GEIS210DTURH1A
ABBPM5630-2ETH-XC
GEHE800ADC140
GEIS220PVIBH1A
Rockwell Automation2198-H070-ERS2
GEIS230SNRTH2A
GEIS215UCVEM08B
GEDS200SHVIG1B
ProSoftPLX31-MBTCP-MBS4
GEDS200PCCAG7A
GEIC200ALG630
Rockwell Automation1769-L30ER-NSE
FoxboroFCM100ET
GEDS200DSPCH1A
GEIC200CHS003
GEIC200UDR001
YokogawaAAV544
ABBPM573-ETH-XC
MotorolaMVME2604-1131B
GEDS200AAHAH1A
Rockwell Automation2094-BC02-M02-M
GEHE800ADC110
FoxboroFBM203B
MotorolaMVME162-453
Rockwell Automation1734-AENTR
EmersonVE3012
ABBPM554-RP-AC
ABB Robotics3HAC043134-003
FoxboroFBM246B
Rockwell Drives80190-480-01-R
GEIS200IGDMH1B
Rockwell Automation2097-V33PR3-LM
Rockwell Automation2097-V32PR4-LM
GEIS200IGPAG2A
GEIC200CHS006
ABB Robotics00-192-284
GEIS230PCAAH1A
GEIC200UEC008
Rockwell Automation5069-L320ERS2
GEDS200STBAG1A
GEIS200EPDMG1B
08

Contact Details

Moore Automation

Send the complete model and requested quantity with your enquiry.

ManagerLeonia

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.