Current command conversion
Controller output words become eight 4 to 20 mA loop currents, with each channel updating every 10 ms and settling through the documented response.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Yokogawa ASI533-S00 S1 | 8-Channel Analog Output Module with Built-In Barrier |
| Item NO. | 2929201 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | YOKOGAWA |
| Brand | YOKOGAWA |
| Creation Time | 2026-11-02 |
YOKOGAWA · CENTUM ENGINEERING RECORD
Yokogawa ASI533-S00 S1 is an eight-channel isolated 4 to 20 mA analog output module with built-in intrinsic-safety barriers for CENTUM field I/O. It converts controller output values into current loops while maintaining an isolated interface between each hazardous-area circuit and the control-system side.
Through the ATSS3 pressure-clamp terminal, Yokogawa ASI533-S00 S1 sends each output current to its assigned field device and supports HART communication on the same loop. The receiving load remains within 750 Ω at 20 mA and 600 Ω at the 23 mA maximum so the module can maintain its commanded current.
The intrinsic-safety behavior of Yokogawa ASI533-S00 S1 links all channels to the module protection condition: short circuits on two or more field channels cause all channels to fail for intrinsic safety. Field wiring, equipotential bonding and associated apparatus must therefore follow the approved system design.
| TECHNICAL ITEM |
|
|---|---|
| Brand | Yokogawa |
| Model | ASI533-S00 S1 |
| Nameplate Suffix | S1 |
| Product Name | Analog output module with built-in barrier |
| Country | Japan |
| Output Channels | 8 isolated |
| Output Signal | 4 to 20 mA |
| Maximum Output | 23 mA |
| Load Resistance | 0 to 750 Ω at 20 mA; 0 to 600 Ω at 23 mA |
| Accuracy | ±48 µA |
| Step Response | 100 ms |
| Update Period | 10 ms |
| Temperature Drift | ±16 µA/10 °C |
| HART Communication | Available |
| Barrier Type | Isolated interface |
| External Terminal | ATSS3 pressure clamp terminal |
| Withstand Voltage | 1500 V AC |
| Current Consumption | 150 mA at 5 V plus 350 mA at 24 V |
| Dimensions | 32.8 × 130 × 107.5 mm |
| Weight | Approx. 0.30 kg |
ASI533-S00 S1 combines analog command conversion, loop communication and barrier separation in one eight-channel output path.
Controller output words become eight 4 to 20 mA loop currents, with each channel updating every 10 ms and settling through the documented response.
HART communication shares the connected current loop, allowing device variables and on-demand communication without a second field cable.
The module detects a current loop that falls below the circuit-open threshold, giving the controller a fault clue distinct from the commanded process value.
The built-in barrier is part of an intrinsically safe system and must be evaluated with the connected field circuit, not as a standalone approval claim.
Compare the ASI533-S00 S1 entity parameters with the field device, cable capacitance and inductance before accepting the loop design.
Two or more shorted field channels cause all channels to fail for intrinsic safety, so grouped output loss requires inspection of every connected loop.
Use the specified ATSS3 terminal, maintain the approved separation and bonding arrangement, and commission one loop at a time under the site safety procedure.
Yokogawa ASI533-S00 S1 supports 0 to 750 Ω at 20 mA and 0 to 600 Ω at its 23 mA maximum; cable and receiver resistance are included in that loop total.
Yokogawa ASI533-S00 S1 is designed so short circuits on two or more field channels cause all channels to fail for intrinsic safety; inspect every loop before resetting service.
Yokogawa ASI533-S00 S1 uses the ATSS3 pressure-clamp terminal family; the single or dual-redundant form must match the installed arrangement.
No. Yokogawa ASI533-S00 S1 includes barrier parameters, isolation and approved terminal arrangements that a standard non-barrier analog output does not reproduce.
For Yokogawa ASI533-S00 S1, confirm the analog loop first, then verify compatible node firmware, HART configuration and direct device connection before troubleshooting communication.
Before removing Yokogawa ASI533-S00 S1, record channel assignments, loop polarity, terminal identity and hazardous-area circuit references, then isolate the approved power sources.
Moore Automation keeps the full manufacturer, model, quantity and destination linked to the same customer enquiry. Supporting photographs and available documentation can be reviewed with the product record when clarification is required.