Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>YOKOGAWA>Yokogawa ARM15A-000 S1 32-Channel Mechanical Relay Contact Input Board
Yokogawa ARM15A-000 S1 32-Channel Mechanical Relay Contact Input Board

Yokogawa ARM15A-000 S1 32-Channel Mechanical Relay Contact Input Board Item NO.: 2929211

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Yokogawa ARM15A-000 S1 32-Channel Mechanical Relay Contact Input Board
Item NO. 2929211
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category YOKOGAWA
Brand YOKOGAWA
Creation Time 2026-11-02

Yokogawa ARM15A-000 S1 32-Channel Mechanical Relay Contact Input Board
YOKOGAWACENTUM MECHANICAL RELAY INPUT

32-Channel Mechanical Relay Contact Input Board

Yokogawa ARM15A-000 S1 32-Channel Mechanical Relay Contact Input Board

01

Hardware Overview

Yokogawa ARM15A-000 S1 is a 32-channel mechanical-relay contact input board for CENTUM field I/O. It accepts dry-contact states through M4 screw terminals and transfers the resulting input status to an ADV151 or ADV161 digital input module.

Within Yokogawa ARM15A-000 S1, the external 24 V DC field supply energizes the individual relay circuits while the internal 24 V DC path supports the board electronics. The two 16-channel groups retain separate field connections, making a group-level supply loss distinguishable from one failed contact.

For commissioning, Yokogawa ARM15A-000 S1 is paired with the documented ATD5A arrangement and AKB331 or AKB337 cable path. Contact resistance, field polarity and group fuses are checked before the controller input image is accepted.

Official full-resolution technical figure for ARM15A-000 S1
02

Engineering Data

Technical item
Brand Yokogawa
Model ARM15A-000 S1
Product Name 32-channel mechanical relay contact input board
Country Japan
Input Channels 32
Terminal M4 screw
Input Contact Dry contact
Contact ON Resistance 150 Ω or less
Contact OFF Resistance 200 kΩ or greater
Supported I/O Module ADV151 with ATD5A or ADV161
Connection Cable AKB331 or AKB337
Field Contact Supply 24 V DC, 13 mA per point
Internal 24 V Consumption 0.32 A maximum
Channel Groups Two groups of 16
Operating Temperature 0 to 50 °C
Operating Humidity 10 to 90% RH, non-condensing
Dimensions 482.6 × 132.5 mm, 3U
Weight Approx. 2.2 kg
03

Product Functions

Yokogawa ARM15A-000 S1 converts 32 independent dry-contact conditions into relay-isolated states that the associated digital input module can read. Its functional value is the repeatable conversion of field contact closure into a grouped, relay-isolated indication without changing the dry-contact circuit into an analog measurement.
01

Contact sensing

Each field contact controls one relay circuit, keeping the physical switch state separate from the controller input electronics. Trace one channel from the M4 terminal through its relay and cable position to the digital input point; this proves the function without relying only on an LED.

›
02

Grouped distribution

Two 16-channel sections distribute field power and make common supply faults visible as a repeatable group pattern. Because sixteen inputs share a field-power group, the function test should include one point from each group and a check of the associated group supply.

›
03

Controller handoff

ADV151 or ADV161 receives the converted states through the documented ATD5A and AKB cable path. The output of the relay interface is the controller-visible contact state, so acceptance requires agreement between the physical contact, relay action and input image.

04

Diagnostics and Protection

Diagnostics and Protection

Yokogawa ARM15A-000 S1

Yokogawa ARM15A-000 S1 troubleshooting follows the signal from the dry contact through the field supply, fuse and relay before the controller image is questioned. Protection and troubleshooting should isolate the fault domain before components are replaced, distinguishing field-contact resistance, group power, fuse condition and controller input.

01

Separate contact from supply

Measure contact resistance and field voltage at the same channel so an open switch is not confused with a missing feeder. A group-wide loss directs the first check to the 24 V source, fuse and common wiring; an isolated point directs it to that contact and terminal.

02

Compare group behavior

If many points fail together, check the common 24 V path and group fuse before replacing individual relays. Measure the contact under the real circuit condition because contamination or cable resistance can prevent the documented ON threshold even when continuity appears acceptable.

03

Verify the handoff

When relay operation is visible but controller data is absent, inspect the ATD5A assignment and AKB331/337 cable seating. After correction, repeat the test at the terminal and in the controller database, then record the affected group so the failure pattern remains traceable.

05

Buyer Questions

01Why do sixteen Yokogawa ARM15A-000 S1 inputs fail together?

On Yokogawa ARM15A-000 S1, a 16-channel pattern points first to the affected group supply, fuse or common wiring rather than 16 independent contacts.

02What contact condition counts as ON for Yokogawa ARM15A-000 S1?

Yokogawa ARM15A-000 S1 treats 150 Ω or less as the documented ON condition; high field resistance should be corrected before acceptance.

03Which modules connect to Yokogawa ARM15A-000 S1?

Yokogawa ARM15A-000 S1 is used with ADV151 plus ATD5A or with ADV161 through the documented AKB331/AKB337 path.

04Can a powered contact be connected directly to Yokogawa ARM15A-000 S1?

Yokogawa ARM15A-000 S1 is specified for dry-contact inputs; an externally powered signal requires the correct interface design rather than direct substitution.

05How should Yokogawa ARM15A-000 S1 be tested after wiring?

Operate one Yokogawa ARM15A-000 S1 contact in each 16-channel group, confirm relay action and then verify the matching controller input before expanding the test.

06Which Yokogawa ARM15A-000 S1 details prevent channel mix-ups during replacement?

Record the Yokogawa ARM15A-000 S1 terminal numbers, group supply, cable identifier and controller channel map so the replacement preserves the same signal path.

06

Our Services

Moore Automation

https://www.mvme.cn/

Moore Automation coordinates multi-brand control and instrumentation enquiries through model review, document handling and commercial communication. Product identity, quantity and destination remain connected while the request is evaluated.

Model reviewIdentifiers and suffixes checked
Record handlingSupporting material coordinated
Commercial detailQuantity and destination retained
Direct routeOne named contact supports review
Moore Automation Our Services original image
07

Alternative Models

GEDS200NATOG3A
MotorolaMVME162-512A1
Allen-Bradley2093-AC05-MP1
Rockwell Automation1756-L83EP
GEDS200SVIAG1A
GEIC200ALG620
GEDS200SPCBG1A
GEIC630MDL304
ABB RoboticsKSP600-3X64
GEIS200EDFFH3A
ABB Robotics3HAC043090-00
GEIS200TREGH1B
YokogawaANR10D
GEHE800HSC601
GEIC200ALG322
GEIS200TTURH1B
GEIS210DTAIH1A
GEIS200BICLH1B
Rockwell Automation5069-L310ERS2
GEDS200EXPSG1A
GEIS215UCVEM06A
MotorolaMVME61006E-0163
MotorolaMVME2604-761-IO
GEIC630MDL375
GEIS200ESELH3A
MotorolaMVME2304-0143
GEIC200MDL744
GEIS200EXHSG4A
GEIC200ALG321
TriconexTRICON 3723X
GEIS220PTURH1B
Rockwell Automation1783-ETAP1T2SFP
Bently Nevada60M500-05-00
ABBPM5650-2ETH-XC
Rockwell Automation2711P-T15C21D8S
GEIS200ESYSH1A
GEIC630CCM390
GEIS200EACFG3A
Rockwell Drives81007-465-51-R
GE Excitation4136J57-G01
YokogawaANB10D-425-CU2N
Rockwell Automation2711P-T15C22D8S
ABB RoboticsDSQC1024A
MotorolaMVME162-723
GEIC630MDL367
GEIC630MDL357
ABB RoboticsKSP600-3X40
ABB RoboticsKSP600-3X40UL
GEIS200EGDMH1A
MotorolaMVME147-010A
GEDS200SHVMG1A
MotorolaMVME2304-0121
GEIS200EGPAG1A
MotorolaMVME6100-0171
GEDS200TCEBG1B
MotorolaMVME162PA-252SE
Rockwell Automation2711P-T19C22D9P
Rockwell Drives80190-320-02-R
TriconexTRICON 4701X
ABB Robotics3HAC055688-004
08

Get in Touch

Moore Automation

Send the complete model and requested quantity.

ManagerLeonia

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.