Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>YOKOGAWA>Yokogawa AAV542-S50 S2 / AAV544-S50 S2 | 16-Channel Voltage Output Modules
Yokogawa AAV542-S50 S2 / AAV544-S50 S2 | 16-Channel Voltage Output Modules

Yokogawa AAV542-S50 S2 / AAV544-S50 S2 | 16-Channel Voltage Output Modules Item NO.: 2929197

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Yokogawa AAV542-S50 S2 / AAV544-S50 S2 | 16-Channel Voltage Output Modules
Item NO. 2929197
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category YOKOGAWA
Brand YOKOGAWA
Creation Time 2026-11-02

Yokogawa AAV542-S50 S2 / AAV544-S50 S2 | 16-Channel Voltage Output Modules

YOKOGAWA · CENTUM ENGINEERING RECORD

Yokogawa AAV542-S50 S2 / AAV544-S50 S2 | 16-Channel Voltage Output Modules

CENTUMI/OMODULE
01

Hardware Overview

Yokogawa AAV542-S50 S2 and Yokogawa AAV544-S50 S2 are sixteen-channel -10 to +10 V analog output modules for CENTUM field control stations. AAV542-S50 S2 uses a non-isolated output structure, whereas AAV544-S50 S2 isolates the channels from the system so the two models address different field-circuit arrangements.

Controller output words reach Yokogawa AAV542-S50 S2 as a common module image and are converted into sixteen voltage signals for loads of 10 kΩ or greater. Yokogawa AAV544-S50 S2 performs the same command conversion with 5 kΩ minimum loads and a 1500 V AC channel-to-system withstand boundary.

Both Yokogawa AAV542-S50 S2 and Yokogawa AAV544-S50 S2 update outputs every 10 ms and settle in 40 ms, but their isolation, load and current-consumption requirements are not interchangeable. The wiring plan therefore follows the exact model rather than the shared voltage range.

02

Engineering Data

TECHNICAL ITEM AAV542-S50 S2 AAV544-S50 S2
Brand Yokogawa
Model AAV542-S50 S2 AAV544-S50 S2
Nameplate Suffix S2 (commonly seen) S2 (commonly seen)
Product Name 16-channel non-isolated voltage output module 16-channel isolated voltage output module
Country Japan
Output Channels 16
Output Signal -10 to +10 V DC
Isolation Non-isolated Isolated channels
Withstand Voltage Not applicable 1500 V AC for 1 minute
Minimum Load 10 kΩ 5 kΩ
Accuracy Larger of ±0.3% FS and ±12 mV
Update Period 10 ms
Output Step Response 40 ms
Temperature Drift Larger of ±0.1%/10 °C and ±10 mV/10 °C
Current Consumption 450 mA at 5 V 860 mA at 5 V
External Connection Pressure clamp terminal, KS cable or MIL connector cable
Dimensions 32.8 × 130 × 107.5 mm
Weight Approx. 0.20 kg
03

Operating Characteristics

AAV542-S50 S2 and AAV544-S50 S2 share the same voltage span and timing but differ at the field-circuit boundary.

01

Command conversion

Each module converts sixteen controller data words into bipolar voltage outputs, updating the complete set every 10 ms.

02

Load behavior

AAV542-S50 S2 requires at least 10 kΩ per output; AAV544-S50 S2 supports 5 kΩ or greater, so receiver impedance affects model selection.

03

Isolation effect

AAV544-S50 S2 provides channel-to-system withstand separation. AAV542-S50 S2 does not, so grounding and common potentials belong to the external design.

04

Installation Highlights

Install the selected module by matching its isolation class and receiver load before conductors are landed.

01

Plan the output circuits

List every receiving device, its input impedance and grounding reference; confirm that each circuit satisfies the chosen module load limit.

02

Mount and terminate

De-energize the node, seat AAV542-S50 S2 or AAV544-S50 S2 in the assigned slot, then connect the documented terminal or cable assembly without mixing channel returns.

03

Commission progressively

Apply module power first, command a safe value on one channel, confirm polarity and measured voltage, and then release the remaining outputs in controlled groups.

05

Buyer Questions

01Which load limit decides between Yokogawa AAV542-S50 S2 / AAV544-S50 S2?

Yokogawa AAV542-S50 S2 / AAV544-S50 S2 use minimum loads of 10 kΩ and 5 kΩ respectively; the connected receiver impedance must satisfy the exact selected module.

02Does Yokogawa AAV542-S50 S2 / AAV544-S50 S2 provide the same isolation?

No. Yokogawa AAV542-S50 S2 / AAV544-S50 S2 share the voltage range, but AAV542-S50 S2 is non-isolated and AAV544-S50 S2 has isolated channels.

03Why is a Yokogawa AAV542-S50 S2 / AAV544-S50 S2 output slow to reach the commanded value?

For Yokogawa AAV542-S50 S2 / AAV544-S50 S2, check the receiver load, wiring capacitance, output update path and the documented 40 ms step response before treating the module as faulty.

04Can Yokogawa AAV542-S50 S2 / AAV544-S50 S2 be wired while the node is energized?

Yokogawa AAV542-S50 S2 / AAV544-S50 S2 should be installed and terminated under the approved de-energized procedure so an output conductor cannot be shorted or assigned to the wrong return.

05What should be measured during Yokogawa AAV542-S50 S2 / AAV544-S50 S2 commissioning?

For Yokogawa AAV542-S50 S2 / AAV544-S50 S2, verify output polarity, zero and full-scale commands, actual receiver impedance and the result at the connected input before releasing all channels.

06Can Yokogawa AAV542-S50 S2 / AAV544-S50 S2 be exchanged only because the dimensions match?

No. Yokogawa AAV542-S50 S2 / AAV544-S50 S2 share the external envelope, but isolation, load and current consumption differ and must be checked in the project design.

06

Our Services

Moore Automation

https://www.mvme.cn/

Moore Automation organizes industrial-part enquiries around complete model strings, requested quantities and destination details. Supporting photographs and available technical files can remain connected to the same record for review.

Model reviewComplete identifiers retained
Supporting filesPhotos and documents attached
Commercial recordQuantity and destination included
07

Alternative Models

GEDS200NATOG3A
MotorolaMVME162-512A1
Allen-Bradley2093-AC05-MP1
Rockwell Automation1756-L83EP
GEDS200SVIAG1A
GEIC200ALG620
GEDS200SPCBG1A
GEIC630MDL304
ABB RoboticsKSP600-3X64
GEIS200EDFFH3A
ABB Robotics3HAC043090-00
GEIS200TREGH1B
YokogawaANR10D
GEHE800HSC601
GEIC200ALG322
GEIS200TTURH1B
GEIS210DTAIH1A
GEIS200BICLH1B
Rockwell Automation5069-L310ERS2
GEDS200EXPSG1A
GEIS215UCVEM06A
MotorolaMVME61006E-0163
MotorolaMVME2604-761-IO
GEIC630MDL375
GEIS200ESELH3A
MotorolaMVME2304-0143
GEIC200MDL744
GEIS200EXHSG4A
GEIC200ALG321
TriconexTRICON 3723X
GEIS220PTURH1B
Rockwell Automation1783-ETAP1T2SFP
Bently Nevada60M500-05-00
ABBPM5650-2ETH-XC
Rockwell Automation2711P-T15C21D8S
GEIS200ESYSH1A
GEIC630CCM390
GEIS200EACFG3A
Rockwell Drives81007-465-51-R
GE Excitation4136J57-G01
YokogawaANB10D-425-CU2N
Rockwell Automation2711P-T15C22D8S
ABB RoboticsDSQC1024A
MotorolaMVME162-723
GEIC630MDL367
GEIC630MDL357
ABB RoboticsKSP600-3X40
ABB RoboticsKSP600-3X40UL
GEIS200EGDMH1A
MotorolaMVME147-010A
GEDS200SHVMG1A
MotorolaMVME2304-0121
GEIS200EGPAG1A
MotorolaMVME6100-0171
GEDS200TCEBG1B
MotorolaMVME162PA-252SE
Rockwell Automation2711P-T19C22D9P
Rockwell Drives80190-320-02-R
TriconexTRICON 4701X
ABB Robotics3HAC055688-004
08

Get in Touch

Discuss the exact product record

MANAGERLeonia

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.