Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>YOKOGAWA>Yokogawa AAI841-H50 Analog I/O Module
Yokogawa AAI841-H50 Analog I/O Module

Yokogawa AAI841-H50 Analog I/O Module Item NO.: 2932314

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Yokogawa AAI841-H50 Analog I/O Module
Item NO. 2932314
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category YOKOGAWA
Brand YOKOGAWA
Creation Time 2026-11-13

Yokogawa AAI841-H50 Analog I/O Module
CENTUM VPFIO analog I/O
HART-enabled mixed analog module

Yokogawa AAI841-H50 Analog I/O Module

8 inputs + 8 outputs4–20 mA with HART
Section 01
01

Product Description

Yokogawa AAI841-H50 is a non-isolated analog input/output module for CENTUM VP field I/O. It combines eight 4–20 mA input channels and eight 4–20 mA output channels in one module, placing field-current acquisition and controller-driven current output in the same FIO position.

On AAI841-H50, each input channel accepts either a two-wire transmitter loop or a four-wire current signal through its assigned pins. The module converts those currents for the control station while the output half converts controller values back into current loops; channel wiring therefore determines whether transmitter power and signal return share the module path.

AAI841-H50 adds HART digital communication to the analog current path. HART data is superimposed on the 4–20 mA loop, and Command 3 process variables can be handled without replacing the analog measurement; the H suffix identifies this communication function, while -50 specifies the basic, non-explosion-protected construction.

Section 02
02

Product Specifications

Specification Specification details
Brand Yokogawa
Model AAI841-H50
Product type Analog input/output module
Country Not specified
Analog inputs 8 channels, 4–20 mA
Analog outputs 8 channels, 4–20 mA
Channel isolation Non-isolated
Digital communication HART
Input accuracy ±16 µA
Output accuracy ±48 µA
Data update period 10 ms
Output load 0–750 Ω; 200–750 Ω at 60–70 °C
Transmitter supply At least 14.8 V at 20 mA
External connection Pressure clamp, KS cable or MIL connector
Approximate weight 0.30 kg
Section 03
03

Current-Loop Signal Flow

AAI841-H50 divides its sixteen analog points between acquisition and actuation. The current path changes direction across the two channel groups, while HART communication remains coupled to the same field loops.

Eight input loops

AAI841-H50 receives eight 4–20 mA signals. Two-wire transmitters can use the module’s transmitter-supply path, while four-wire devices provide their own field power and return only the measured current.

Eight output loops

AAI841-H50 drives eight 4–20 mA output circuits. The connected load must stay within the specified resistance range so the commanded current can be established across the field loop.

Analog plus HART

AAI841-H50 carries HART digital information over the analog current. Command 3 variables travel through the HART channel while the continuous 4–20 mA value remains available to the controller.

Section 04
04

Wiring and Channel Limits

AAI841-H50 depends on the selected terminal interface and on loop conditions at each channel. These boundaries connect the module’s published accuracy and diagnostic behavior to actual field wiring.

Terminal choices

AAI841-H50 can connect through a pressure-clamp terminal block, a KS cable interface or a MIL-style connector arrangement. The selected interface must preserve the input/output pin assignment.

Open-output detection

AAI841-H50 detects an open output circuit when the output current falls below 0.65 mA. This indication concerns the output loop and is separate from an input-channel reading.

Load and temperature

AAI841-H50 permits a 0–750 Ω output load through most of its range; at 60–70 °C the lower bound becomes 200 Ω. The load check therefore belongs to the output loop and ambient condition together.

Section 05
05

Common Questions

How should two-wire and four-wire transmitters be distinguished on AAI841-H50?

For AAI841-H50, a two-wire transmitter uses the module supply and signal path, while a four-wire transmitter has an external supply and sends its current into the designated input pins.

Can AAI841-H50 inputs and outputs be treated as sixteen identical channels?

No. AAI841-H50 has eight receiving channels and eight driving channels. Their current direction, terminal pins, accuracy figures and diagnostics are different.

What should be checked when an AAI841-H50 output reports an open circuit?

For AAI841-H50, verify the output-loop continuity and whether current is below the 0.65 mA detection threshold, then confirm that the connected load is within the permitted range.

Does AAI841-H50 require a separate HART module?

AAI841-H50 includes HART communication in the analog I/O module. The field loop still carries 4–20 mA, with HART data superimposed on that current path.

Which terminal style can be used with AAI841-H50?

AAI841-H50 supports documented pressure-clamp, KS-cable and MIL-connector arrangements. The selected terminal or cable must match the channel pin assignment.

What details prevent a wrong AAI841-H50 configuration request?

State AAI841-H50 in full and include the terminal interface, input transmitter type, output-load range and HART requirement. This separates the exact HART version from related analog modules.

Section 06
06

Customer Support

Moore Automation

https://www.mvme.cn

Moore Automation keeps the manufacturer, full order code, quantity and destination together in one enquiry record. Datasheet checks and commercial communication then refer to the same identifier.

Exact model recorded
Requested documents coordinated
Quantity and destination retained
One communication trail
Section 07
07

Related Products

Collection 01
TriconexTRICON 3009
Vibro-Meter200-510-SSS-1HH
B&RX20AT2222
Woodward9907-167
HIMA984333002
Bently Nevada3300 5 mm
FoxboroFCM2F10
Bosch RexrothHCS01.1E-W0008-A-03-B-ET-EC-NN-L4-NN-FW
Siemens6ES7972-0BB42-0XA0
GEIC5005CAC0000
Rockwell Automation1794-IB32
EmersonKJ4110X1-BC1
ABB3HAC058992-003
TriconexTRICON 8312
Vibro-Meter111-402-000-012
Collection 02
B&RX20CM4810
Woodward8200-1300
HIMA984323602
Bently Nevada1900/65A & 2300
FoxboroFPS480-24
Siemens6ES7193-4CB70-0AA0
GEIC5005CAC0001
Rockwell Automation1794-IE8
EmersonSE4022
ABBACS550-01-012A-4
TriconexTricon 3006
Vibro-Meter111-402-000-013
B&RX20CM8281
Woodward8200-1301
HIMA984621702
Collection 03
Bently Nevada990/991 Transmitter
Siemens6GK1900-0AB00
GEIC5005TAW0000
Rockwell Automation1794-IF4I
EmersonKC4011X1-BP1
ABBACS550-01-017A-4
TriconexTricon 3007
Vibro-Meter200-560-000-1HH
B&RX20BC0083
WoodwardFlex500
HIMA984323702
Bently Nevada330180-50-00
Siemens3RK1901-0CB01
GEIC5005TAW1000
Rockwell Automation1794-IF8IH
Collection 04
EmersonKC3010X1-BA2
ABBACS550-01-045A-4
TriconexTricon 4329
Vibro-Meter204-900-000-011
B&RX20IF2772
Woodward8200-1355
HIMA984334902
Bently Nevada330105-02-12-05-02-05
Siemens3RK1901-1YA10
GEIC5005TAW4000
Rockwell Automation1794-OB16
EmersonKL2101X1-BA1
ABBACS550-01-059A-4
TriconexTricon 4352B
Vibro-MeterCA201-A2A50000780

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.