Product Name Yokogawa AAI143-H50/K4A00 16-Channel Isolated HART Analog Input Module
Item NO. 2932017
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category ABB
Brand ABB
Creation Time 2026-11-12

Yokogawa AAI143-H50/K4A00 16-Channel Isolated HART Analog Input Module
YokogawaCENTUM VP FIO

Yokogawa AAI143-H50/K4A00 16-Channel Isolated HART Analog Input Module

Product identityHART
01
Product identity

Product Summary

Yokogawa AAI143-H50/K4A00 is a 16-channel isolated analog input module for 4 to 20 mA field signals with HART communication. Each input channel is isolated, allowing the module to convert process current into Field Control Station data while keeping the specified channel separation.

The H suffix in Yokogawa AAI143-H50/K4A00 identifies the HART-capable version. Process values enter the FCS I/O image and HART variables are handled through the HART communication function, so control data and device information can be used without treating them as the same signal path.

The 50 suffix of Yokogawa AAI143-H50/K4A00 indicates the basic, non-explosion-protected hardware with the applicable status-display style, while /K4A00 specifies the ATK4A-00 KS cable interface adapter for the AEA4D terminal board. The full suffix and option string defines the delivered connection arrangement.

02
Technical record

Specification Details

Specification AAI143-H50/K4A00
Brand Yokogawa
Product Name 16-Channel Isolated HART Analog Input Module
Country Japan
System family CENTUM VP / FIO
Input channels 16, isolated
Input signal 4 to 20 mA DC
Allowable input current 24 mA
Input resistance, power ON 270 Ω at 20 mA to 350 Ω at 4 mA
Input resistance, power OFF 500 kΩ or greater
Accuracy ±16 µA
Data update period 10 ms
Step response time 100 ms
Withstand voltage 1500 V AC between input and system for 1 minute
HART communication Available
Connection option /K4A00: ATK4A-00 KS cable interface adapter
03
Sixteen current inputs

Isolated Signal Acquisition

AAI143-H receives standardized current signals while maintaining channel isolation and a defined conversion path into the FCS.

01

Current loop input

Each channel accepts 4 to 20 mA and is evaluated against the specified input resistance and allowable current. Loop power and transmitter headroom remain field-design checks.

02

Channel isolation

The isolated-channel architecture reduces direct coupling between field loops. Shielding, grounding and barrier selection still follow the installation design.

03

FCS data image

Converted current values are placed in the control-system I/O image for regulatory or sequence functions. Scaling and bad-signal handling are configured per channel.

04
Device variables alongside process data

HART Data Path

HART communication adds device information to the analog measurement path without replacing the 4-20 mA control value.

01

HART variables

Supported HART variables are exchanged through the module communication function and made available to the FCS environment for device monitoring or management.

02

Control reference

The regulatory and sequence blocks reference the I/O image, preserving the process-value path while HART data remains associated with the field device.

03

KS cable option

The /K4A00 option identifies the ATK4A-00 adapter and AEA4D terminal-board connection. Cable and terminal-board identity are verified together.

05
Practical checks

Questions & Answers

Why does Yokogawa AAI143-H50/K4A00 show 0 mA even though the transmitter is powered?

For Yokogawa AAI143-H50/K4A00, measure the loop at the assigned channel, verify polarity and continuity through the ATK4A-00/AEA4D path, then compare the FCS channel assignment and scaling.

Why are HART variables unavailable from Yokogawa AAI143-H50/K4A00 while the 4-20 mA value is valid?

Yokogawa AAI143-H50/K4A00 can pass the analog value even when HART communication is not established. Check HART support in the node, channel configuration, loop impedance and device HART settings.

Can a Zener barrier be inserted directly ahead of Yokogawa AAI143-H50/K4A00?

The Yokogawa AAI143-H50/K4A00 documentation does not permit a Zener barrier for this module in an intrinsically safe application; use the specified isolation-barrier approach and approved system design.

What does /K4A00 control on Yokogawa AAI143-H50/K4A00?

On Yokogawa AAI143-H50/K4A00, /K4A00 specifies the ATK4A-00 KS cable interface adapter used with the AEA4D terminal board. Inspect the adapter and board, not only the I/O module.

How should a drifting Yokogawa AAI143-H50/K4A00 channel be isolated?

Swap the field loop to a known input only under an approved test plan, then compare Yokogawa AAI143-H50/K4A00 raw current, configured range, terminal resistance, grounding and transmitter output to separate field drift from channel behavior.

Why must the complete Yokogawa AAI143-H50/K4A00 suffix be retained in a spare request?

Yokogawa AAI143-H50/K4A00 combines HART capability, hardware style and the KS cable adapter option. Shortening the request to AAI143 can produce a different connection and protection arrangement.

06
Moore Automation

Shipping Services

Moore Automation

https://www.mvme.cn

Moore Automation coordinates packing and shipment records for industrial I/O modules, adapters and associated terminal hardware. The full Yokogawa option code can remain visible on the packing list and receiving note.

Shipment updates can include carrier information and package status, while handling notes call attention to connector protection and electrostatic precautions for the module and adapter.

Connector-safe packingOption-code packing listsCarrier status coordinationReceiving-note preparation
07
Mixed-brand selection

Suggested Products

Siemens 6ES7412-1XJ05-0AB0
ABB 3HNA029043-0
Siemens SKC32.60
ABB 3HNA023093-001
Siemens 6GK7343-1EX20-0XE0
ABB 3HNA018784-001
Siemens 6ES7124-1FA00-0AB0
ABB 3HNA024284-001
Siemens 6GK7442-1RX00-0XE0
ABB BRC300 / SPBRC300
ABB BRC400 / SPBRC400
ABB BRC410 / SPBRC410
ABB BRC100 / SPBRC100
Siemens 6ES7323-1BL00-0AA0
ABB DI810 3BSE008508R1
GE IC695ACC400-DA
Schneider Electric 140XTS00100
Rockwell Automation 1756-EN2TR
Omron CP1W-40EDT
Bently Nevada 21000-16-10-00-054-04-02
Honeywell LCM-320
Mitsubishi Electric FX1N-40MR-ES/UL
Allen-Bradley 700-K40E-ZY
B&R X20CP1684X
Yaskawa CIMR-AC4A0072AAA
WAGO 750-613/006-000
Beckhoff KL3062
Foxboro FBM201C
Bosch Rexroth VT-VRPA2-1-11/V0/T1
HIMA X-COM 01 001
Lenze E82EV152-4B
Emerson VE801R
Vibro-Meter 444-620-000-111-A1-B100-C01
Yokogawa AAI143-S50/A4S00
ProSoft 2150-AGA 1747-KE
TRICONEX 8310
Motorola MVME167-033B
SICK CLV250-1020
Phoenix Contact RAD-0200
SEW-EURODRIVE MDX61B0008-5A3-4-0T
Triconex 3626X
Danfoss VLT2840
ICS Triplex T8151C
Woodward 9907-010
Moxa EDS-405A-MM-ST-T
Pepperl+Fuchs RLK39-8-2000/31/40a/116
Festo CPX-M-FB33
FANUC A05B-1523-B202
GE Fanuc IC670GBI001
ifm PN5000
Knick B12526800A
Rockwell Drives 80026-044-06-R
Eaton DILM65 XTCE065D00F
Horner HE800RTD000
ADLEE AS2-115
ANYBUS 021620-B
Balluff BCL45R1F100
Eaton MTL 787S
FMS EMGZ306A
HORNER HE800WCM900
08
Direct enquiry

Contact Details

CompanyMoore Automation
Sales ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.