Current loop input
Each channel accepts 4 to 20 mA and is evaluated against the specified input resistance and allowable current. Loop power and transmitter headroom remain field-design checks.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Yokogawa AAI143-H50/K4A00 16-Channel Isolated HART Analog Input Module |
| Item NO. | 2932017 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | ABB |
| Brand | ABB |
| Creation Time | 2026-11-12 |
Yokogawa AAI143-H50/K4A00 is a 16-channel isolated analog input module for 4 to 20 mA field signals with HART communication. Each input channel is isolated, allowing the module to convert process current into Field Control Station data while keeping the specified channel separation.
The H suffix in Yokogawa AAI143-H50/K4A00 identifies the HART-capable version. Process values enter the FCS I/O image and HART variables are handled through the HART communication function, so control data and device information can be used without treating them as the same signal path.
The 50 suffix of Yokogawa AAI143-H50/K4A00 indicates the basic, non-explosion-protected hardware with the applicable status-display style, while /K4A00 specifies the ATK4A-00 KS cable interface adapter for the AEA4D terminal board. The full suffix and option string defines the delivered connection arrangement.
| Specification | AAI143-H50/K4A00 |
|---|---|
| Brand | Yokogawa |
| Product Name | 16-Channel Isolated HART Analog Input Module |
| Country | Japan |
| System family | CENTUM VP / FIO |
| Input channels | 16, isolated |
| Input signal | 4 to 20 mA DC |
| Allowable input current | 24 mA |
| Input resistance, power ON | 270 Ω at 20 mA to 350 Ω at 4 mA |
| Input resistance, power OFF | 500 kΩ or greater |
| Accuracy | ±16 µA |
| Data update period | 10 ms |
| Step response time | 100 ms |
| Withstand voltage | 1500 V AC between input and system for 1 minute |
| HART communication | Available |
| Connection option | /K4A00: ATK4A-00 KS cable interface adapter |
AAI143-H receives standardized current signals while maintaining channel isolation and a defined conversion path into the FCS.
Each channel accepts 4 to 20 mA and is evaluated against the specified input resistance and allowable current. Loop power and transmitter headroom remain field-design checks.
The isolated-channel architecture reduces direct coupling between field loops. Shielding, grounding and barrier selection still follow the installation design.
Converted current values are placed in the control-system I/O image for regulatory or sequence functions. Scaling and bad-signal handling are configured per channel.
HART communication adds device information to the analog measurement path without replacing the 4-20 mA control value.
Supported HART variables are exchanged through the module communication function and made available to the FCS environment for device monitoring or management.
The regulatory and sequence blocks reference the I/O image, preserving the process-value path while HART data remains associated with the field device.
The /K4A00 option identifies the ATK4A-00 adapter and AEA4D terminal-board connection. Cable and terminal-board identity are verified together.
For Yokogawa AAI143-H50/K4A00, measure the loop at the assigned channel, verify polarity and continuity through the ATK4A-00/AEA4D path, then compare the FCS channel assignment and scaling.
Yokogawa AAI143-H50/K4A00 can pass the analog value even when HART communication is not established. Check HART support in the node, channel configuration, loop impedance and device HART settings.
The Yokogawa AAI143-H50/K4A00 documentation does not permit a Zener barrier for this module in an intrinsically safe application; use the specified isolation-barrier approach and approved system design.
On Yokogawa AAI143-H50/K4A00, /K4A00 specifies the ATK4A-00 KS cable interface adapter used with the AEA4D terminal board. Inspect the adapter and board, not only the I/O module.
Swap the field loop to a known input only under an approved test plan, then compare Yokogawa AAI143-H50/K4A00 raw current, configured range, terminal resistance, grounding and transmitter output to separate field drift from channel behavior.
Yokogawa AAI143-H50/K4A00 combines HART capability, hardware style and the KS cable adapter option. Shortening the request to AAI143 can produce a different connection and protection arrangement.
Moore Automation coordinates packing and shipment records for industrial I/O modules, adapters and associated terminal hardware. The full Yokogawa option code can remain visible on the packing list and receiving note.
Shipment updates can include carrier information and package status, while handling notes call attention to connector protection and electrostatic precautions for the module and adapter.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found