Measuring electrical conditions
The control reads generator, mains and bus quantities so the configured logic can evaluate synchronization and operating limits.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Woodward 8440-2080 / 8440-2085 easYgen generator control |
| Item NO. | 2919430 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | WOODWARD |
| Brand | Woodward |
| Creation Time | 2026-10-14 |
easYgen generator controls · front-panel display variants
Woodward 8440-2080 / 8440-2085 are easYgen generator-control variants that place generator measurements, breaker logic and operator settings in a front-panel control platform. The two references belong to different easYgen option positions, so the complete part-number combination identifies which control package is being handled.
In the Woodward 8440-2080 / 8440-2085 control family, voltage, current and bus measurements are processed for generator and mains decisions, while configurable logic drives breaker commands and engine start/stop sequences. The display and keypad provide the local operator path, and the control exposes data through its communication interfaces.
At the control interface, Woodward 8440-2080 / 8440-2085 use the selected CT input, generator/mains/bus measurements and breaker feedback to execute the configured generator sequence. The 8440-2085 package carries the easYgen-3500XT display position, while 8440-2080 carries the easYgen-2300 P1 position.
| Technical Item |
|
|---|---|
| Brand | Woodward |
| Product family | easYgen generator controls |
| Page models | 8440-2080 / 8440-2085 |
| 8440-2080 position | easYgen-2300 P1, 5 A CT, front-panel display |
| 8440-2085 position | easYgen-3500XT P1, front-panel display |
| Mounting | Front-panel display variants |
| Generator voltage measurement | Up to 690 VAC, three phase |
| Generator current | 1 A or 5 A selectable, three phase |
| Operating modes | Automatic, Manual, Stop and test |
| Breaker transition | Open and closed transition logic |
| Communication | CAN, Ethernet Modbus TCP, USB serial and RS-485 Modbus RTU |
| Configuration | PC configuration through USB serial and ToolKit |
| Event recorder | Real-time-clock event entries |
| Protection coverage | Generator, engine, mains and bus protection functions |
Woodward 8440-2080 / 8440-2085 process electrical measurements and operating commands for generator-control tasks.
The control reads generator, mains and bus quantities so the configured logic can evaluate synchronization and operating limits.
Breaker logic issues open or closed-transition commands while the selected operating mode determines the control sequence.
Configurable start/stop and load-related logic links engine status with the generator operating state.
The communication paths of Woodward 8440-2080 / 8440-2085 carry operating values, commands and service data between the control and external equipment.
FlexCAN interfaces connect the control to supported Woodward devices and distributed generator-control networks.
Ethernet Modbus TCP and RS-485 Modbus RTU provide data exchange with plant supervision or other controllers.
The USB serial interface and ToolKit software provide the PC path used for configuration and service access.
How should the 8440-2080 / 8440-2085 pair be identified before wiring?
Record the complete Woodward 8440-2080 / 8440-2085 reference from the nameplate and match the display, CT-input and control-family position before wiring. Do not use the display style alone to identify the control variant.
Which measurement path must be checked for Woodward 8440-2080 / 8440-2085?
Confirm the generator, mains and bus measurement wiring required by the selected control package. The 1 A or 5 A current-transformer setting must agree with the connected measurement circuit before the controller is configured.
Can the communication wiring for Woodward 8440-2080 / 8440-2085 be treated as one interface?
No. Keep CAN, Ethernet Modbus TCP, RS-485 Modbus RTU and USB service wiring on their intended ports. Verify the protocol and port assignment in the selected control configuration rather than moving a cable by connector shape.
What should be checked if breaker commands from Woodward 8440-2080 / 8440-2085 do not complete?
Check the selected operating mode, breaker feedback and the configured transition logic in sequence. A command path is not validated until the controller sees the corresponding feedback state.
How is the 8440-2080 / 8440-2085 configuration loaded?
Use the control’s USB serial service path with the Woodward ToolKit configuration for the exact unit. Save the application and confirm the nameplate variant before applying settings.
Does Woodward 8440-2080 / 8440-2085 have the same temperature option?
Do not assume the two references share the same temperature or display option. Confirm the exact part number and the applicable product specification before assigning an operating-temperature limit.
Moore Automation supplies industrial automation and electronic components across PLC, DCS, HMI, drive, sensor and related spare-part categories. Each enquiry keeps the manufacturer and complete Woodward model attached to the requested item.
Send the complete model and requested quantity with your enquiry.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found