Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>SIEMENS>Siemens 6FC5370-5AA20-0AA0 PPU 261.2 Horizontal Panel Processing Unit
Siemens 6FC5370-5AA20-0AA0 PPU 261.2 Horizontal Panel Processing Unit

Siemens 6FC5370-5AA20-0AA0 PPU 261.2 Horizontal Panel Processing Unit Item NO.: 2945420

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Siemens 6FC5370-5AA20-0AA0 PPU 261.2 Horizontal Panel Processing Unit
Item NO. 2945420
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category SIEMENS
Brand SIEMENS
Creation Time 2026-11-26

Siemens 6FC5370-5AA20-0AA0 PPU 261.2 Horizontal Panel Processing Unit | Moore Automation
SIEMENSSINUMERIK 828D
Industrial automation
PPU 261.2

Panel-based CNC processing

Siemens 6FC5370-5AA20-0AA0 PPU 261.2 Horizontal Panel Processing Unit

Horizontal operator panelCNC hardware record
MODELPPU 261.2
01Product

Hardware Overview

SINUMERIK 828D horizontal operator-panel arrangement and front interfaces.

The horizontal PPU 261.2 hardware identified by 6FC5370-5AA20-0AA0 combines CNC processing, PLC execution and the operator-panel interface in one SINUMERIK 828D machine-front assembly.

Display functions, alphanumeric and numerical keys, machine-oriented controls and protected service interfaces are integrated in 6FC5370-5AA20-0AA0. Its CompactFlash position carries system software and user data.

Hardware article 6FC5370-5AA20-0AA0 is supplied without the CNC software package. The system-software and license record remains separate even though both records belong to the completed 828D control configuration.

02Data

Engineering Data

Article number6FC5370-5AA20-0AA0
Brand
Siemens
Product Type
SINUMERIK 828D PPU 261.2
Brand Country
Germany
Panel orientation
Horizontal
CNC software
Not included in the hardware order number
Operator interface
Integrated display and membrane keyboard
Storage interface
CompactFlash slot for system software and user data
Front USB
Available behind the protective cover
Ethernet service port
Front service socket
Machine-panel support
Connectable operator and machine-control components
Drive integration
Used with the SINAMICS S120 Combi system
Panel role
CNC, PLC and HMI functions in one panel unit
Mounting format
Machine-panel installation
03Function

Operator Panel Control Stack

6FC5370-5AA20-0AA0 brings CNC visualization, key operation and protected service access into one machine-front workflow. Operator actions pass from the panel interface into the control functions without requiring a separate workstation for routine use.

01

Operating path

The front panel presents CNC visualization, data entry and machine operation from the same physical unit.

02

Engineering context

Dedicated key groups reduce dependence on an external PC keyboard during normal machining and setup.

03

Practical result

Protected USB and Ethernet service access support program transfer and diagnostic work at the machine.

04System

Panel and Drive Communication

6FC5370-5AA20-0AA0 coordinates the panel, CNC/PLC execution and the connected drive platform as one machine-control chain. Each layer keeps its own role while exchanging the commands and states needed for coordinated motion.

01

Operating path

The PPU coordinates motion commands and PLC signals with the connected SINAMICS S120 Combi drive system.

02

Engineering context

Machine-control panels and distributed peripherals extend operator and field functions beyond the integrated keys.

03

Practical result

The hardware, system software and drive configuration are separate engineering records that converge in the running CNC system.

05Help

Buyer Questions

Before teams check CompactFlash contents before startup, which 6FC5370-5AA20-0AA0 condition deserves attention?

On 6FC5370-5AA20-0AA0, verify that the CompactFlash card is present, seated and contains the intended system data before treating a startup fault as a panel failure.

When users need to identify the correct horizontal panel version, where should 6FC5370-5AA20-0AA0 diagnosis begin?

The practical check for 6FC5370-5AA20-0AA0 is to check that the installed hardware is the horizontal PPU 261.2 version and compare the complete article number before matching panel cutout or key layout.

During commissioning, how should 6FC5370-5AA20-0AA0 be checked to use the protected front interfaces?

When working with 6FC5370-5AA20-0AA0, technicians should use the protected front Ethernet and USB interfaces for approved service tasks and close their covers again to preserve the panel environment.

What should technicians avoid overlooking on 6FC5370-5AA20-0AA0 when they handle the separate CNC software record?

Begin the 6FC5370-5AA20-0AA0 review with this sequence: Keep the PPU article number separate from the CNC software and license record because the panel hardware is supplied without that software package.

Which observation on 6FC5370-5AA20-0AA0 is most useful for teams that must review a dark or unresponsive operator panel?

With 6FC5370-5AA20-0AA0 in service, check supply, CompactFlash status and panel indications in that order before replacing a dark or unresponsive operator panel.

How should evidence from 6FC5370-5AA20-0AA0 be separated when engineers connect the panel to S120 Combi?

6FC5370-5AA20-0AA0: Trace the configured machine connection from the PPU through the SINAMICS S120 Combi system and confirm that both control and drive sides report communication.

06Moore

Global Supply Network

MOORE AUTOMATION

https://www.mvme.cn/

Moore Automation coordinates international automation enquiries through a broad supplier and logistics network.

Brand, complete model, delivery destination and documentation remain connected from initial review through dispatch.

Complete identityBrand and full model retained.
Document controlAvailable records kept together.
Global coordinationDestination and logistics aligned.
Assigned contactOne communication chain.
www.mvme.cn
08Contact

Get in Touch

Moore AutomationGet in TouchSend the complete Siemens model and your contact details.
ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.