Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>SIEMENS>Siemens 6ES7217-1AG40-0XB0 | SIMATIC S7-1200 CPU 1217C DC/DC/DC
Siemens 6ES7217-1AG40-0XB0 | SIMATIC S7-1200 CPU 1217C DC/DC/DC

Siemens 6ES7217-1AG40-0XB0 | SIMATIC S7-1200 CPU 1217C DC/DC/DC Item NO.: 2927220

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Siemens 6ES7217-1AG40-0XB0 | SIMATIC S7-1200 CPU 1217C DC/DC/DC
Item NO. 2927220
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category SIEMENS
Brand SIEMENS
Creation Time 2026-10-26

Siemens 6ES7217-1AG40-0XB0 | SIMATIC S7-1200 CPU 1217C DC/DC/DC
CPU 1217C
SIEMENS · VERIFIED TECHNICAL RECORD
Siemens 6ES7217-1AG40-0XB0 | SIMATIC S7-1200 CPU 1217C DC/DC/DC

A high-capacity compact CPU with standard 24 V DC I/O, RS-422/485 differential channels, analog I/O and two PROFINET ports.

01

Product Description

Siemens 6ES7217-1AG40-0XB0 is a SIMATIC S7-1200 CPU 1217C DC/DC/DC compact controller. Its onboard terminal groups combine ten standard 24 V DC inputs, four RS-422/485 differential inputs, six standard 24 V DC transistor outputs, four RS-422/485 differential outputs, two 0-10 V analog inputs and two 0-20 mA analog outputs.

Across the communication path, Siemens 6ES7217-1AG40-0XB0 provides two integrated PROFINET ports for controller, engineering and device communication. The differential I/O terminals are separate from the standard DC channels, so the selected signal standard, paired conductors and terminal references must follow the CPU 1217C wiring arrangement rather than a conventional single-ended digital circuit.

For program and panel planning, Siemens 6ES7217-1AG40-0XB0 provides 250 KB of program/data work memory, 4 MB of integrated load memory and a 20.4-28.8 V DC supply range. Current consumption can rise from the CPU-only rated value as signal boards, communication modules and other expansions are added, so the complete installed configuration belongs in the power calculation.

Official technical figure for Siemens 6ES7217-1AG40-0XB0
02

Product Specifications

Technical Item Value
Brand Siemens
Model 6ES7217-1AG40-0XB0
Product Name SIMATIC S7-1200 CPU 1217C DC/DC/DC
Country Germany
Product Family SIMATIC S7-1200
Supply Voltage 20.4-28.8 V DC
Standard Digital Inputs 10 x 24 V DC
Differential Inputs 4 x RS-422/485
Standard Digital Outputs 6 x 24 V DC transistor, 0.5 A
Differential Outputs 4 x RS-422/485
Analog Inputs 2 x 0-10 V DC
Analog Outputs 2 x 0-20 mA
PROFINET Interface 2 integrated ports
Program/Data Memory 250 KB
Integrated Load Memory 4 MB
Firmware Version V4.7
Engineering Requirement STEP 7 V20 or later
Rated Current, CPU Only 600 mA
Maximum Current with Expansion 1,600 mA
Typical Power Loss 12 W
03

Communication and Connectivity

Siemens 6ES7217-1AG40-0XB0 combines two PROFINET ports with standard 24 V channels and separate RS-422/485 differential I/O. Successful integration depends on keeping the Ethernet network, standard I/O commons and differential signal pairs electrically and logically distinct.
01

Build the PROFINET path

Assign the device name and IP settings of Siemens 6ES7217-1AG40-0XB0 in the project, connect the two Ethernet ports according to the planned topology and verify each downstream device online. Do not use the second port as an undocumented plant-network bridge merely because the physical connector is available.

02

Wire differential inputs as pairs

Connect each RS-422/485 input of Siemens 6ES7217-1AG40-0XB0 with its designated positive and negative conductors and preserve cable pairing through the terminal route. Keep these references separate from the standard 24 V input common and apply shielding or termination required by the connected source.

03

Wire and verify differential outputs

Route the RS-422/485 outputs of Siemens 6ES7217-1AG40-0XB0 to the receiving device as matched pairs, observing polarity and the destination interface requirements. Test the differential group separately from the standard transistor outputs so a polarity or reference error is not masked by unrelated I/O.

04

Configuration and Programming

Siemens 6ES7217-1AG40-0XB0 must be selected as the exact CPU 1217C hardware version before its mixed onboard resources are addressed. The project should organize standard digital, differential, analog and network signals into separate groups that can be commissioned and diagnosed independently.
01

1. Match hardware and firmware

Insert Siemens 6ES7217-1AG40-0XB0 by full order number and supported firmware, then add the installed signal board and right-side modules in physical order. Compare the project device view with the cabinet before assigning addresses or downloading the program.

02

2. Organize the channel groups

Create separate program tags and diagnostic handling for the standard digital, RS-422/485 differential and analog channels of Siemens 6ES7217-1AG40-0XB0. Use names that identify the electrical interface so a differential point cannot be reassigned casually to a standard 24 V circuit.

03

3. Download and commission by interface

Calculate the expansion and 24 V demand, compile the complete project and download it to Siemens 6ES7217-1AG40-0XB0. Prove PROFINET communication, standard I/O, differential pairs and analog channels in separate tests, recording polarity, addresses and observed diagnostics for each group.

05

Common Questions

Why do the RS-422/485 inputs on Siemens 6ES7217-1AG40-0XB0 remain inactive while the standard inputs work?

Check whether the field signal is actually differential and trace both conductors to the dedicated Siemens 6ES7217-1AG40-0XB0 input pair. A single 24 V wire and standard-input common do not reproduce the required RS-422/485 circuit.

How should intermittent PROFINET communication on Siemens 6ES7217-1AG40-0XB0 be isolated?

For Siemens 6ES7217-1AG40-0XB0, inspect both port link states, connector seating, device name, IP parameters and switch path. Compare the online hardware identity with the exact project CPU before changing program logic.

Why does Siemens 6ES7217-1AG40-0XB0 restart after expansion hardware is added?

Measure the 24 V DC supply at Siemens 6ES7217-1AG40-0XB0 during startup and total the CPU, signal-board and module demand. Expansion can raise current toward the documented maximum even when the unloaded supply voltage appears normal.

Can the analog outputs of Siemens 6ES7217-1AG40-0XB0 drive a voltage input directly?

The onboard Siemens 6ES7217-1AG40-0XB0 analog outputs are specified as 0-20 mA channels. Confirm that the receiving device accepts a current input and wire the complete loop rather than assuming a 0-10 V output.

What should be retained when replacing Siemens 6ES7217-1AG40-0XB0?

Keep the Siemens 6ES7217-1AG40-0XB0 firmware level, hardware configuration, network identity, channel assignments, analog scaling and differential wiring record together. Matching only the CPU family name does not restore those settings.

Why can an input value be plausible but assigned to the wrong process point on Siemens 6ES7217-1AG40-0XB0?

The mixed onboard groups on Siemens 6ES7217-1AG40-0XB0 use different terminal blocks and channel addresses. Compare the physical X10-X13 terminal position with the configured tag address before recalibrating the field device.

06

Customer Support

Moore Automation parts support

Moore Automation

https://www.mvme.cn

Moore Automation provides a concise contact route for industrial automation enquiries involving exact model references, requested quantities and available product records.

Questions about the Siemens 6ES7217-1AG40-0XB0 request can stay with the same enquiry while commercial details and relevant technical files are coordinated.

Model referenceThe requested identifier stays explicit.
Document coordinationAvailable records can follow the enquiry.
Named contactLeonia supports follow-up.
07

Related Products

Bosch RexrothDKC10.3-040-7-FW
Vibro-MeterXIO16T
YokogawaAAI841-H50
ProSoftPLX32-MBTCP-PND
GEIC660BBA105
Rockwell Automation1734-SSI
Siemens6ES7212-1AE40-0XB0
ABBPM511V16
EmersonA6220
Bently Nevada330103-00-04-10-02-00
B&RX20AI8321
ABB BaileyIMMFP03
MotorolaMVME2304-0113
TriconexTRICONEX 3506X
HIMAF3 AIO 8/4 01
FoxboroFBM205
Bosch RexrothDKC11.3-040-7-FW
Vibro-Meter200-582-200-011
YokogawaS2SC70D-SA11010
ProSoftPLX51-DNPS
GEIC660BBA106
Rockwell Automation1734-RS232
Siemens6ES7214-1AG40-0XB0
ABBCI547
EmersonA6312
Bently Nevada330103-00-05-10-02-00
B&RX20AO2622
ABB BaileyIMMPI01
MotorolaMVME2304-0121
TriconexTRICONEX 3510
HIMAF3 DIO 8/8 01
FoxboroFBM206
Bosch RexrothDKC02.3-100-7-FW
Vibro-Meter200-582-200-013
YokogawaS2SC70D-SA12010
ProSoftPLX51-HART-4O
GEIC660BBD020
Rockwell Automation1734-4IOL
Siemens6ES7214-1BG40-0XB0
ABBPM864AK01
EmersonA6370D
Bently Nevada330104-00-06-10-02-00
B&RX20AO4632
ABB BaileyIMSPM01
MotorolaMVME2304-0123
TriconexTRICONEX 3511
HIMAF3 DIO 20/8 02
FoxboroFBM207B
Bosch RexrothDKC03.3-100-7-FW
Vibro-Meter200-582-300-013
YokogawaA2FVX1-D02010
ProSoftPLX82-MNET-61850
GEIC660BBD021
Rockwell Automation1734-IE4S
Siemens6ES7214-1HG40-0XB0
ABBPM851AK01
EmersonA6371-10
Bently Nevada330104-01-05-50-02-00
B&RX20AT2222
ABB BaileyIMASI13
08

Enquiry Information

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.