IC694ALG390C: How RX3i Turns PLC Commands into Valve and Drive Control
2026-11-23

IC694ALG390C: How RX3i Turns PLC Commands into Valve and Drive Control

From PLC logic to process action

The important question is not only what IC694ALG390C is. It is how an RX3i control decision becomes a voltage command that moves a valve, changes a drive speed or positions an actuator.

2Independent outputs
±10 VBipolar command
RX3iControl platform
FieldPhysical action

What does this module actually do in the process?

A control program can calculate the correct output, but the process does not respond until that digital decision becomes a usable field signal. In a PACSystems RX3i installation, IC694ALG390C can provide that final connection between PLC logic and physical equipment.

The module receives output data from the controller, converts it into an analog voltage and sends the command to a valve positioner, drive, actuator or another continuously controlled device.

The last step between logic and physical action

Consider a flow-control loop. A transmitter measures the process, the RX3i controller compares the measurement with the setpoint, and the program calculates a new command. The result still exists as digital data until the analog output module converts it into a field voltage.

Three jobs inside one control path

1

Receive the command

The module receives the output value produced by the RX3i application.

2

Convert the value

Digital data is converted into a proportional bipolar analog voltage.

3

Deliver the action

The voltage is delivered to the field device that performs the physical work.

IC694ALG390C provides two independent voltage-output channels. The module produces the electrical command, while the project scaling determines what that command means in the application.

Two channels can perform two different jobs

PROCESS CONTROLValve position

The RX3i application calculates a required position and the voltage command is interpreted by the valve positioner.

MOTOR CONTROLDrive-speed reference

The module provides a continuously variable command to the analog reference input of a compatible drive.

MOTION REFERENCEActuator direction

A project may use positive and negative voltage to represent direction and magnitude for a compatible actuator.

Correct PLC logic is only one part of the result

1Channel assignment: which valve, drive or actuator receives each output?
2Project scaling: what physical action does the configured voltage represent?
3Power and wiring: how are the module, terminal block and isolated supply connected?
4Receiving device: is its analog input configured for the same command range?
5Process record: can another engineer trace the command from the program to the field equipment?

The field effect of an output state must be understood

The IC694ALG390 family supports an output that can default to 0 V or hold its last state when the CPU enters Stop or Reset, according to the installed hardware configuration. The correct behavior is the one documented and approved for the process—not a universal preference.

Question Why it matters What should be documented
What does 0 V mean? It may represent a controlled position, zero speed or another project-defined command. The physical response of the connected device.
What does Hold Last State mean? The receiving equipment may continue acting on the last voltage command. The approved behavior during CPU Stop or Reset.
Where does isolated 24 VDC come from? The output path depends on the installed module-power arrangement. The identified supply, terminal path and drawing reference.
Who verifies the result? A software value alone does not prove the expected field action. The responsible operator, engineer and acceptance record.

Record IC694ALG390C as installed, not as a generic analog module

EXACT NAMEPLATE RECORDIC694ALG390CKeep the suffix, revision evidence, rack position and field-interface record together.
Complete catalog numberUse a readable nameplate photograph rather than appearance alone.
Rack and slotConnect the physical module with the RX3i hardware configuration.
Terminal block and jumpersCapture the installed hardware arrangement before it changes.
Channel assignmentsIdentify the equipment controlled by Channel 1 and Channel 2.
External supplyRecord the isolated 24 VDC source and drawing reference.
Field-device setupDocument how the receiving device interprets the voltage command.

Eight items that make an enquiry more useful

Complete module photographShow the front, sides and terminal area clearly.
Readable nameplatePreserve IC694ALG390C and all visible revision information.
Rack positionRecord the backplane and exact installed slot.
Terminal arrangementCapture the terminal block and jumper positions.
Channel 1 assignmentIdentify the first connected valve, drive or actuator.
Channel 2 assignmentIdentify the second field command independently.
Power arrangementShow the external isolated 24 VDC source and return path.
Project recordsInclude the relevant I/O list, wiring drawing and scaling note.

Questions about IC694ALG390C in an RX3i control loop

What does IC694ALG390C do in an RX3i system?
It converts output data from the RX3i controller into two independent analog voltage commands used by compatible valves, drives, actuators and other field devices.
Is IC694ALG390C a current-output module?
No. It belongs to the two-channel bipolar analog voltage-output family. Do not describe the two outputs as 4–20 mA channels.
Can the two channels control different types of equipment?
Yes, when the project design and receiving equipment support the assigned voltage command. Each channel should have its own field-device, scaling and drawing record.
Why is the CPU Stop or Reset behavior important?
Because the configured output state becomes a physical command to the connected equipment. The team must know what 0 V or the held voltage means to that device and process.
Why keep the “C” suffix in the hardware record?
The complete nameplate identity distinguishes the installed revision from a generic family reference. Do not remove the suffix when preparing photographs, asset records or enquiries.
What is the fastest way to review an installed module?
Start with the nameplate, rack and slot, terminal block, jumper positions, isolated 24 VDC source, both channel assignments and the applicable wiring drawing.

Technical basis

PACSystems RX3i System ManualGFK-2314 · IC694ALG390 family operation, output data, power and field-wiring information
PACSystems RX3i product documentationPlatform, rack-based I/O and installed-hardware identification references

Technical enquiry

Connect the module record to the real control loop

Send the complete module number, revision, rack position, terminal photographs, channel assignments and available wiring records. Browse more GE automation hardware on MVME.

ManagerLeonia
Phone / WhatsApp+86 180 3017 5807
Websitewww.mvme.cn

>> Triconex Online Hardware Maintenance: Reducing Process Interruption While Maintaining Safety Functions

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.