GE IC695CPE302 PACSystems RX3i CPU
Product Description
IC695CPE302 is an RX3i controller CPU with an embedded two-port Gigabit Ethernet switch. It runs machine logic, exchanges controller data and provides a compact migration point for Ethernet-connected RX3i systems.
Its two RJ45 ports form the CPU's embedded switched Ethernet interface, while the serial and USB connections serve separate commissioning roles. Preserve the controller address set, protocol configuration, retained values and energy-pack state as one recovery package.
Technical Specifications
Network Architecture and Ring Planning
Port role
Treat the two RJ45 sockets as a managed controller switch, not two isolated CPU networks.
MRP boundary
Ring operation depends on the required PROFINET controller configuration and compatible firmware.
Address record
Preserve IP, subnet, gateway, device names and produced/consumed exchange definitions.
CPU Changeover Control
Upload
Upload and archive the PAC Machine Edition project, hardware configuration and retained values.
Record
Record firmware, option settings and Ethernet topology before removing the running CPU.
Restore
Restore the project offline, then validate I/O, interlocks, time synchronization and every protocol connection.
FAQ
Which order-code checks belong to the Network Architecture and Ring Planning decision for IC695CPE302?
Match the complete order code, hardware revision, backplane and installed system configuration; a similar family name is not enough for replacement selection.
What must be backed up before the CPU Changeover Control procedure for IC695CPE302?
Save the editable application, hardware configuration, communication parameters, retained production data and the firmware or software baseline used by this PACSystems RX3i CPU.
How does port role affect Network Architecture and Ring Planning for IC695CPE302?
Treat the two RJ45 sockets as a managed controller switch, not two isolated CPU networks.
Why does mrp boundary need separate verification during CPU Changeover Control for IC695CPE302?
Ring operation depends on the required PROFINET controller configuration and compatible firmware.
How should IC695CPE302 complete the CPU Changeover Control sequence before return to service?
Complete the documented startup sequence, verify diagnostics and communications, test the application under controlled conditions and confirm the applicable machine interlocks.
Moore Automation handles enquiries across ABB, Siemens, GE Fanuc, Schneider Electric, Honeywell, Emerson, Foxboro, Triconex, Bently Nevada and other automation brands.
The mix spans distributed control, programmable control, condition monitoring and operator-interface families.






No related record found