IC695ALG600-DD
IC695ALG600-DD provides eight general-purpose input channels and two cold-junction compensation channels for PACSystems RX3i control systems.
Each channel is configured in Proficy Machine Edition for voltage, current, thermocouple, RTD or resistance measurement. The module must be installed in an RX3i Universal Backplane.
Built for configurable field measurement
Software configuration
No module jumpers are required.
Automatic calibration
Autocalibration runs at power-up.
Channel diagnostics
Fault, alarm, overrange and underrange reporting is available per channel.
Hot insertion
The module supports hot insertion and extraction.
Input monitoring
Open-circuit detection is available for most input types; RTD short-circuit detection is supported.
User scaling
Floating-point scaling is configurable for the application.
Local indication
Module OK, Field Status and TB LEDs show operating condition.
Terminal-block detection
Insertion and removal status is monitored by the module.
IC695ALG600-DD technical data
All principal electrical, channel and configuration parameters are consolidated in this section.
Module layout and field connections
Functional signal overview
Lifecycle record
For replacement of an installed module, match the complete catalog and revision marking, terminal block, channel configuration, sensor wiring, scaling, alarms and CPU/PME compatibility before commissioning.
Send the installed revision, quantity and terminal-block requirement.
sales@mvme.cn
+86 18030175807
Universal field measurement in RX3i systems
Process instrumentation
Acquisition of voltage and current signals from transmitters used for pressure, flow, level and other process variables.
Temperature monitoring
Thermocouple and RTD measurement for machinery, process equipment and production assets.
Resistance measurement
Direct resistance inputs where the configured range and field wiring match the supported channel setup.
Five checks before ordering
What information should be supplied with an inquiry?
Provide the complete catalog marking, hardware revision, required quantity and whether a matching terminal block is needed.
Does the terminal block come with the module?
The removable terminal block is ordered separately. Confirm the installed terminal-block type before placing an order.
What should be recorded before removing an installed module?
Retain the existing hardware configuration, channel assignments, scaling, alarms and field-wiring records for commissioning.
What must be checked when replacing an earlier revision?
Verify the full revision suffix, RX3i CPU firmware, PAC Machine Edition version, terminal block and project configuration.
Is a one-for-one successor identified?
No designated one-for-one replacement is published. Replacement planning must be based on the installed system configuration and compatibility requirements.
Industrial automation model index
| Column A | Column B | Column C |
|---|---|---|
| EX-P-0600 | IC200MDL640F | 6ES7193-4CB30-0AA0 |
| ABB 281844-020-03 | 760ATC | KL1722 |
| DDLE802 | M1032-61635 | KL3454 |
| CMDSLCZBU | M1032-61602 | EEID4A EA900102 |
| LBB4443/00 | M1032-61605 | 400-P0W |
| 253-TVLW-NXHG-C5-BD | WAP125-A-K9-BR | 5WG1 528-1AB02 |
| IRM-S01AN-B | TN1P4PA62A D8AW2 | 140011 |
| CM485 | 181B0729 SPR-CMB21640 | 2N 9151002 |
| MOD2-2R | ABB TU510-A3T 1SAP210800R0001 | ASY0001241 |
| ABB TU532 1SAP217000R0001 | ABB TU516-H 1SAP215000R0001 | 5WG1 523-1AB02 |
| MFM383A-C-CE | ABB TU542-H 1SAP215200R0001 | A4 51 84 Rex2000 D42 |
| E1242 | TP-RDR-100A | PXC100.D |
| AS-F9165UA-02 | OEM750X-M2 | 6499-11-00 |
| IO44E01KNX | TXA112 | HT-9001-URW |
| ABB DO524 1SAP240700R0001 | AM 503 | MX-OPT-F2.0-L65-L25 |
| MDM021 | 4930275 | IC695ALG608 |
| L24734-F655-A5 | ABB G4001 2TME050080N0001 | IC695ALG616 |
| 2CDG110064R0011 | 1SBN153510R8106 ZA75 | IC695ALG626 |
| LGAN-WF100 | TWDXCAISO | IC695ALG628 |
| CP1E-NA20DT1-D CP1W-8ET1 | DMC-4K-HD | IC695ALG704 |






No related record found