Keep four commons independent
Inputs 1–8, 9–16, 17–24 and 25–32 each return to their own common. This grouping allows separate field supplies or logic polarity without combining the references.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | GE IC694MDL660-BC RX3i 32-Point Input Module |
| Item NO. | 2942597 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | GE |
| Brand | GE |
| Creation Time | 2026-11-19 |
Four isolated 24 V DC input groups
A 32-point positive/negative-logic input module with selectable filtering and hot-insertion support.
GE IC694MDL660-BC is a PACSystems RX3i discrete input module with thirty-two 24 V DC points. The inputs are divided into four isolated groups of eight, and each group has its own common so the module can accept positive-logic or negative-logic field circuits.
Each channel on GE IC694MDL660-BC can use one of seven configurable input-filter times from 0.5 to 100 milliseconds. Thirty-two point LEDs report the sensed states, while separate indicators identify module health and terminal-block presence.
GE IC694MDL660-BC installs in an RX3i universal backplane I/O slot and supports controlled hot insertion on compatible systems. A removable 36-terminal block carries the four groups, with commons at terminals 9, 18, 27 and 36.
GE IC694MDL660-BC converts four electrically separated groups of field contacts into one 32-point RX3i input image.
Inputs 1–8, 9–16, 17–24 and 25–32 each return to their own common. This grouping allows separate field supplies or logic polarity without combining the references.
The configurable filter holds each input state until it remains valid for the selected interval, reducing false transitions from contact bounce or electrical noise.
Point LEDs mirror the filtered input image, while OK and terminal-block indications report module health and the presence of the removable field connector.
Diagnosis follows the signal from group power and common wiring through filtering to the controller input image.
If one group disappears while the others remain valid, its field supply, common and terminal range form the first diagnostic boundary.
A long filter can make a short pulse invisible to logic even when the field contact operates. Comparing pulse width with the configured interval prevents a wiring-only diagnosis.
The terminal-block status indication separates a removed or incomplete field connector from an internal module fault or absent field voltage.
For GE IC694MDL660-BC, verify whether each group is wired for positive or negative logic and measure the channel voltage relative to that group’s own common.
GE IC694MDL660-BC uses commons at terminals 9, 18, 27 and 36 for the input groups 1–8, 9–16, 17–24 and 25–32.
GE IC694MDL660-BC divides its points into four groups of eight, so a lost group supply, common or terminal connection can remove exactly eight channels at once.
GE IC694MDL660-BC applies the selected input filter and the controller reads the resulting image on its I/O cycle, so timing can create a brief difference during a transition.
GE IC694MDL660-BC filters each input from 0.5 to 100 ms; a pulse shorter than the configured interval can be rejected even when the field device changes state.
Before handling GE IC694MDL660-BC in a supported hot-insertion system, record the slot, logic state, field supplies, terminal-block status and site procedure for controlled I/O removal.
Moore Automation prepares I/O shipments with attention to removable terminal blocks, connector protection and visible product labels. For GE IC694MDL660-BC, the packing record can keep the module, included field connector, quantity and destination tied together.
| Brand / Model | Brand / Model | Brand / Model | Brand / Model |
|---|---|---|---|
| Rockwell Automation1761-NET-AIC | GEIC695CMM004 | Siemens6DL1131-6BL00-0PH1 | ABBACS580-01-206A-4 |
| Rockwell Automation1761-NET-ENI | GEIC695CMX128 | Siemens6ES5465-4UA13 | ABBACS880-01-017A-3 |
| Rockwell Automation1772-LP1 | GEIC695CPE302 | Siemens6ES7193-1FL50-0XA0 | ABBACS880-01-025A-3 |
| Rockwell Automation1772-LP2 | GEIC695CPE305 | Siemens6GK5202-2JR00-2BA6 | ABBACS880-01-032A-3 |
| Rockwell Automation1772-LP3 | GEIC695CPE310 | Siemens6SL3544-0FB21-1PA0 | ABBACS880-01-045A-3 |
| Rockwell Automation1772-M16 | GEIC695CPE400 | Siemens7MH4601-1AA01 | ABBACS880-01-061A-3 |
| Rockwell Automation1772-M8 | GEIC695CPS400 | ABBACS880-01-087A-3 | Rockwell Automation1772-ME |
| GEIC695CPU310 | ABBACS880-01-105A-3 | Rockwell Automation1772-P1 | GEIC695CPU315 |
| ABBACS880-01-145A-3 | Rockwell Automation1773-L1A | GEIC695CRU320 | ABBACS880-01-169A-3 |
| Rockwell Automation1773-L1B | GEIC695ECM850 | ABBACS880-01-206A-3 | Rockwell Automation1775-KA |
| GEIC695GCG001 | ABBCI854AK01 | Rockwell Automation1775-L4 | GEIC695NIU001 |
| ABBDI810 | Rockwell Automation1775-LP8 | GEIC695PBS301 | Rockwell Automation1775-LPA |
| GEIC695PNC001 | Rockwell Automation1775-ME4 | GEIC695PNS101 | Rockwell Automation1775-ME8 |
| GEIC695RMX128 | Rockwell Automation1775-MEAA | GEIC695RMX228 | Rockwell Automation1775-MEF |
| GEIC755CKW07CDM | Rockwell Automation1775-P1 | GEIC755CKW10CDM | Rockwell Automation1775-S4A |
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found