Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>GE>GE IC200UDD212 / IC200UDD220 / IC200UDD240 VersaMax Micro DC PLCs
GE IC200UDD212 / IC200UDD220 / IC200UDD240 VersaMax Micro DC PLCs

GE IC200UDD212 / IC200UDD220 / IC200UDD240 VersaMax Micro DC PLCs Item NO.: 2908097

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name GE IC200UDD212 / IC200UDD220 / IC200UDD240 VersaMax Micro DC PLCs
Item NO. 2908097
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category GE
Brand GE
Creation Time 2026-09-14

GE IC200UDD212 / IC200UDD220 / IC200UDD240 VersaMax Micro DC PLCs
GE • VERSAMAX MICRO

GE IC200UDD212 / IC200UDD220 / IC200UDD240 VersaMax Micro DC PLCs

Integrated discrete control options for compact machine panels.

Product Overview

These GE VersaMax Micro PLCs provide integrated discrete I/O for compact machine control. IC200UDD212 is the 28-point, 12 VDC controller with 16 inputs and 12 transistor outputs; IC200UDD220 is the 20-point, 24 VDC controller with eight sink outputs; and IC200UDD240 is the 40-point, 24 VDC controller with 16 sink outputs. All three combine configurable DC inputs with compact control hardware, but the point count, supply requirement, and output arrangement must be matched to the panel design.

Technical Data

Technical item IC200UDD212 IC200UDD220 IC200UDD240
Brand GE
Product type VersaMax Micro PLC controller with DC inputs and transistor outputs
Built-in I/O 28 points 20 points 40 points
Discrete inputs 16 × 12 VDC 12 × 24 VDC 24 × 24 VDC
Discrete outputs 12 × 12 VDC transistor 8 × 24 VDC sink transistor 16 × 24 VDC sink transistor
Controller power 12 VDC nominal 24 VDC nominal 24 VDC nominal
Input range 0–15 VDC 0–30 VDC 0–30 VDC
High-speed counter frequency 10 kHz 100 kHz 100 kHz
Pulse / PWM capability Up to 5 kHz Up to 65 kHz Up to 65 kHz

Product Features

Start by matching the field-input standard to the installed panel: the 28-point version uses sixteen 12 VDC inputs, while the 20- and 40-point versions use 24 VDC inputs. Confirm the controller power and input range together before transferring wiring.

For normal machine sensing, map each configurable DC input in the application and verify the required point count. For output wiring, keep the transistor or sink-output circuit matched to its correct DC load and field supply; output technology is not interchangeable with relay wiring.

Wiring Reference

Use the correct official wiring diagram for the exact model during panel work. The diagrams below are cropped from the manufacturer user manual to retain terminal labels while removing manual headers and margins. Select the supply, field wiring, and output circuit for the actual model—not a neighbouring family member.

Official wiring diagram for IC200UDD212
Official wiring diagram — IC200UDD212
Official wiring diagram for IC200UDD220
Official wiring diagram — IC200UDD220
Official wiring diagram for IC200UDD240
Official wiring diagram — IC200UDD240

Performance

Use the faster 24 VDC controllers when the application needs up to 100 kHz high-speed counting or up to 65 kHz pulse/PWM functions. The 12 VDC version has a 10 kHz counter and 5 kHz pulse/PWM limit, so that variant must be selected from the motion or pulse requirement rather than I/O total alone.

During commissioning, prove ordinary inputs and high-speed channels separately. Record the programmed counter/PWM assignment and test only with the published supply and load arrangement, because a conventional output load does not validate a high-speed function.

Product FAQ

Which supply check prevents choosing the wrong IC200UDD212 / IC200UDD220 / IC200UDD240 controller?

Match the existing 12 or 24 VDC controller supply and input standard before comparing point count.

How can IC200UDD212 / IC200UDD220 / IC200UDD240 retain high-speed counting after replacement?

Confirm the configured fast channel and its published 10 or 100 kHz limit for the installed variant.

Why will a relay-wiring plan not suit IC200UDD212 / IC200UDD220 / IC200UDD240 outputs?

These models use transistor or sink DC outputs, so the field supply and load polarity must match the documented circuit.

What should be recorded before moving IC200UDD212 / IC200UDD220 / IC200UDD240 wiring?

Record power, input common, output type, point assignment and the original program configuration.

How can an IC200UDD212 / IC200UDD220 / IC200UDD240 field-load fault be isolated?

Check the external DC supply, load polarity and individual output circuit before concluding that the controller is defective.

When is a larger IC200UDD212 / IC200UDD220 / IC200UDD240 point count not an upgrade?

When the controller supply, input voltage or high-speed function differs from the installed application.

Moore Automation

Moore Automation supplies industrial automation parts for maintenance and replacement planning, including PLC, DCS, HMI, drives, and related components.

  • Original products
  • Fast delivery
  • 1-year warranty
  • 12-hour online response
Moore Automation warehouse and service team — Moore10.png

Contact Us

ManagerLeonia
WhatsApp+8618030175807

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.