Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>GE>GE IC200PNS001-AC VersaMax PROFINET Scanner Module
GE IC200PNS001-AC VersaMax PROFINET Scanner Module

GE IC200PNS001-AC VersaMax PROFINET Scanner Module Item NO.: 2944342

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name GE IC200PNS001-AC VersaMax PROFINET Scanner Module
Item NO. 2944342
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category GE
Brand GE
Creation Time 2026-11-23

GE IC200PNS001-AC VersaMax PROFINET Scanner Module
GEVersaMax PROFINET
PNPROFINET scanner
Remote I/O head-end

GE IC200PNS001-AC VersaMax PROFINET Scanner Module

Copper PROFINET head-end for scanning a VersaMax remote I/O node.

Product Description

GE IC200PNS001-AC is a VersaMax PROFINET scanner that acts as the head-end of a remote I/O node. It scans the installed VersaMax modules, publishes input data to the PROFINET controller and applies received output data to the node.

The copper version of GE IC200PNS001-AC provides two 10/100 Mbps RJ-45 interfaces. The integrated carrier accepts the scanner power supplies and connects the head-end to as many as eight VersaMax I/O modules in one station.

GE IC200PNS001-AC manages module configuration, alarms, status/control words and configured I/O states if network communication is interrupted. The production interval is selected from the supported PROFINET update rates.

Product Specifications

GE IC200PNS001-AC
Specification Value
Brand GE
Product Name VersaMax PROFINET Scanner Module
Series VersaMax Remote I/O
Network Role PROFINET IO-Device head-end
PROFINET Support Version 2.3 Class A IO-Device
Copper Interfaces Two RJ-45 ports
Port Speed 10/100 Mbps
Power Consumption 0.60 A at 5 V DC
Module Height 132 mm (5.2 in)
Module Width 134 mm (5.28 in)
Carrier Integrated
Specification Value
USB One Micro-B, USB 2.0 full-speed
Status Bits 32 input status bits
Control Bits 32 output control bits
Update Rates 1, 2, 4, 8, 16, 32, 64, 128, 256 or 512 ms
IP Addresses One
MAC Addresses Three
I/O Modules per Station Eight maximum
Station I/O Data 2880 bytes total
Input Data Limit 1440 bytes
Output Data Limit 1440 bytes
Operating Temperature 0 to 60 °C surrounding air without fan

PROFINET Remote Node

GE IC200PNS001-AC turns a row of VersaMax modules into one configured PROFINET IO-Device.

HEAD-END

Own the local I/O row

The scanner discovers and services the modules attached to its integrated carrier and station bus.

INPUTS

Publish field data

The scanner collects module inputs and sends the configured data image to the PROFINET controller at the selected production interval.

OUTPUTS

Apply controller commands

Output data received from the controller is distributed to the assigned VersaMax output modules in the node.

Scanner Network Behavior

GE IC200PNS001-AC combines two switched copper ports with local status/control data and module-aware fault handling.

PORTS

Two copper connections

The RJ-45 interfaces support line or ring-oriented network layouts when the overall PROFINET configuration is valid.

STATUS

Node condition reporting

Status bits, alarms and module diagnostics make the remote-node state available to the controller.

LOSS

Configured I/O response

If the controller connection is lost, the scanner manages individual module output behavior according to the stored configuration.

Common Questions

Why does GE IC200PNS001-AC power up but not join the PROFINET controller?

For GE IC200PNS001-AC, compare its device name, IP settings, GSDML selection, controller ownership and physical port link with the configured node.

What should be checked when one module is missing behind GE IC200PNS001-AC?

Compare the GE IC200PNS001-AC station configuration with the physical module order, carrier seating, power budget and the first module that stops reporting.

Can both GE IC200PNS001-AC ports be connected into a loop?

Only use both GE IC200PNS001-AC ports in a loop when the PROFINET media-redundancy design is correctly configured; an unmanaged circular path can disrupt communication.

Why is I/O data delayed on GE IC200PNS001-AC?

Review the GE IC200PNS001-AC configured update rate, controller loading, network topology, device count and module scan behavior before changing the production interval.

Which data helps diagnose a GE IC200PNS001-AC fault?

Collect the GE IC200PNS001-AC LED state, device name, IP address, controller alarm, module list, port link status and downloaded hardware configuration.

What belongs in a GE IC200PNS001-AC request?

Include GE IC200PNS001-AC exactly, node module list, copper-network requirement, firmware context, quantity, condition and destination.

Remote I/O Enquiry Desk

Moore Automation

https://www.mvme.cn/

Moore Automation covers widely used automation brands and product families, including PLC, DCS, remote I/O, gateways and human-machine interfaces. For GE IC200PNS001-AC, a dedicated enquiry record can keep the scanner, local module row and copper-network requirement together.

Multi-brand coverageGE, ABB, Siemens and other families
Node reviewHead-end and module list aligned
Direct follow-upOne contact coordinates the request

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.