Product Name GE IC200MDL750K VersaMax 32-Point DC Output Module
Item NO. 2944216
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category GE
Brand GE
Creation Time 2026-11-22

GE IC200MDL750K VersaMax 32-Point DC Output Module
GEVersaMax Modular I/O
32DC output points
Discrete output module

GE IC200MDL750K VersaMax 32-Point DC Output Module

Two field-power groups with positive-logic switching and point status indication.

Product Overview

GE IC200MDL750K is a 32-point 12/24 V DC positive-logic discrete output module for the VersaMax modular I/O platform. Its outputs are divided into two groups of 16, providing two field-power sections within one compact module.

For GE IC200MDL750K, connected loads are switched toward the positive side of the external DC supply. Processing is handled by the installed VersaMax CPU or network interface unit, while load current enters through the group DC+ and DC- field terminals on the selected I/O carrier.

On GE IC200MDL750K, individual point indicators display output state, the FLD PWR indicators show field-power presence and the OK indicators show backplane-power presence. Output count available at one time depends on supply voltage, ambient temperature and module orientation.

Technical Specifications

Technical ledger
Brand GE
Model IC200MDL750K
Product Name VersaMax 32-Point 12/24 V DC Positive Logic Output Module
Country Not specified
Series VersaMax Modular I/O
Module Type Discrete output module
Output Logic Positive or sourcing logic
Output Points 32
Output Organization Two groups of 16 outputs
External Power Supply +10.2 to +30 V DC; +12/24 V DC nominal
Backplane Current 90 mA maximum from 5 V output
Output Voltage +10.2 to +30 V DC
Technical ledger
Output Voltage Drop 0.3 V maximum
Load Current 0.5 A at 30 V DC maximum, resistive
Inrush Current 2.0 A maximum for 100 ms
Output Leakage Current 0.5 mA at 30 V DC maximum
On Response Time 0.2 ms maximum
Off Response Time 1.0 ms maximum
Group-to-Group Isolation 250 V AC continuous; 1500 V AC for 1 minute
Point-to-Point Isolation None
Output Protection No internal fuses
Status Indication One LED per point, FLD PWR LED and OK LED
Module Dimensions 110 × 66.8 × 50 mm, excluding carrier and mating connectors

Output Organization

IC200MDL750K separates controller-side point commands from the external field-power path, keeping 32 outputs organized as two visible wiring groups.

A

Two independent output banks

IC200MDL750K organizes the output field into two banks of 16. The split keeps each group’s field-power pair beside its associated outputs and gives the controller a clear 32-point map.

B

Positive-logic load switching

Each IC200MDL750K output switches the load toward the positive side of the external DC supply. The load circuit is therefore completed through the external field supply rather than through backplane power.

C

Controller-side point control

The VersaMax CPU or network interface unit performs the module processing. IC200MDL750K receives the commanded point states through the carrier interface while field wiring carries load current separately.

Installation Highlights

Installation centers on matching the carrier terminal format, distributing field power to both output groups and observing the load-dependent operating limits.

A

Match the carrier terminal format

IC200MDL750K can be used with carrier arrangements that present two or three terminal rows. Use the carrier diagram that matches the installed hardware so outputs 1-32 and both field-power pairs stay correctly identified.

B

Plan the external field supply

Provide the DC source at the group DC+ and DC- terminals and keep polarity visible in the wiring schedule. The FLD PWR indication confirms the presence of field power at IC200MDL750K.

C

Account for load and mounting conditions

The permitted number of simultaneously energized IC200MDL750K points varies with supply voltage, ambient temperature and mounting orientation. Inductive loads also require external suppression at the field circuit.

Frequently Asked Questions

Why can IC200MDL750K show an active point but the connected load remains off?

For IC200MDL750K, check the external field supply at the group DC+ and DC- terminals, then trace the assigned output terminal, load return and field wiring. The point LED represents the output state, so it does not by itself confirm that current is reaching the load.

How should the two output groups on IC200MDL750K be wired?

IC200MDL750K divides its 32 outputs into two groups of 16. Keep the DC+ and DC- connections for each group visible in the wiring record, match outputs 1-16 to side A and outputs 17-32 to side B, and do not assume an undocumented common arrangement.

What should be checked before connecting inductive loads to IC200MDL750K?

Before IC200MDL750K drives an inductive load, confirm the load current and supply voltage, provide the required external suppression circuit, and review the number of simultaneously energized points against ambient temperature and mounting orientation.

Can IC200MDL750K be treated as the same item as a 16-point VersaMax output module?

No. IC200MDL750K is a 32-point, two-group output module. Verify the full model, point count, carrier terminal arrangement and field supply record instead of selecting by the similar 12/24 V DC description alone.

Which records help investigate an IC200MDL750K output problem?

Keep the IC200MDL750K model, carrier type, terminal map, external supply reading, commanded output state, LED state and connected load reference together. This separates a configuration issue from field-power, wiring and load-side conditions.

What information should accompany an IC200MDL750K enquiry?

An IC200MDL750K enquiry should include the complete model suffix, quantity, installed carrier, required condition, destination and any available label or wiring record. These details keep the requested execution separate from similar VersaMax output modules.

Brand Supply Scope

Moore Automation

https://www.mvme.cn/

Moore Automation coordinates enquiries across PLC, DCS, HMI, drives, remote I/O, industrial communication and related automation families. For GE IC200MDL750K, the complete model, quantity, requested condition and destination can be retained as one enquiry record.

Exact-model reviewModel and suffix kept together
Document coordinationAvailable product information linked to the request
Shipment follow-upPacking and tracking details coordinated after order confirmation

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.