Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>GE>GE Fanuc IC695PBM300-EC RX3i PROFIBUS Master Module
GE Fanuc IC695PBM300-EC RX3i PROFIBUS Master Module

GE Fanuc IC695PBM300-EC RX3i PROFIBUS Master Module Item NO.: 2945435

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name GE Fanuc IC695PBM300-EC RX3i PROFIBUS Master Module
Item NO. 2945435
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category GE
Brand GE
Creation Time 2026-11-26

GE Fanuc IC695PBM300-EC RX3i PROFIBUS Master Module

GE Fanuc · PACSystems RX3i

GE Fanuc IC695PBM300-EC RX3i PROFIBUS Master Module

A Universal Backplane interface that exchanges cyclic and DP-V1 data between an RX3i CPU and a PROFIBUS network.

01 · ID

Solution Overview

GE Fanuc IC695PBM300-EC is an RX3i PROFIBUS master module for the Universal Backplane. It gives the host CPU a managed path to PROFIBUS-DP slave devices, transferring their cyclic input data into controller memory and sending controller output data back onto the fieldbus.

Within IC695PBM300-EC, the network configuration assigns each slave an address and maps its input and output bytes. The module can coordinate as many as 125 slaves, while the complete network image is bounded to 3,584 input bytes and 3,584 output bytes; any single slave can contribute no more than 244 bytes in either direction.

A three-LED status group on IC695PBM300-EC separates module condition, network condition and communication activity. DP-V1 services add acyclic read, write and alarm transfers alongside the cyclic exchange, so configuration records and device diagnostics do not have to be packed into the normal process-data scan.

02 · DATA

Electrical & Mechanical Data

Technical Item IC695PBM300-EC
Brand GE Fanuc
Product Type PACSystems RX3i PROFIBUS master module
Brand Country United States
Backplane PACSystems RX3i Universal Backplane
Protocol PROFIBUS-DP with DP-V1 services
Maximum Slaves 125
Network Input Capacity 3,584 bytes total
Network Output Capacity 3,584 bytes total
Per-Slave Process Data Up to 244 input bytes and 244 output bytes
Parameter Data Up to 9 KB
Supported Global Controls Sync and Freeze
Host CPU Requirement CPU firmware 2.9 or later
Module Indication Three status LEDs
EC Revision Firmware 1.04
03 · CORE

PROFIBUS Cyclic Data Exchange

The IC695PBM300-EC process-data path is organized around a repeated controller-to-fieldbus exchange rather than direct point wiring.

Stage 01

Map

The configuration assigns byte ranges to each slave and establishes where those ranges appear in controller memory.

Stage 02

Collect

The master polls configured slaves and gathers their current input bytes into the network input image.

Stage 03

Transfer

The RX3i CPU reads that image and updates the output bytes required by the control application.

Stage 04

Distribute

The master places the new output data into the corresponding slave telegrams on the next bus cycle.

Explanation 01

Memory Relationship

The configured slave map defines which controller memory bytes belong to each device. Input telegrams update only their assigned ranges, while output ranges are taken from the application record for the next bus cycle.

Explanation 02

Capacity Check

The 244-byte per-slave limit and 3,584-byte network-direction limit are independent checks. A valid individual mapping can still make the complete configuration too large when every station is counted.

Explanation 03

Freeze and Sync

Freeze coordinates selected slave input snapshots; Sync coordinates selected output updates. These global-control functions affect a defined slave group and do not replace the ordinary cyclic exchange.

The per-slave and total byte limits apply together. A slave mapping can fit its own 244-byte boundary yet still exceed the aggregate network image when combined with the remaining stations.

04 · CORE

Slave Addressing and DP-V1 Services

Cyclic I/O and acyclic device services share the same PROFIBUS connection, but IC695PBM300-EC treats them as different transactions.

Stage 01

Address

Every slave must have a unique station address that agrees with the hardware or device configuration.

Stage 02

Parameterize

Startup data establishes the device operating record before normal cyclic transfer is accepted.

Stage 03

Read / Write

DP-V1 requests reach parameter and diagnostic records without altering the cyclic I/O layout.

Stage 04

Alarm

A DP-V1 alarm can report a device event while process data continues on its assigned byte path.

Explanation 01

Startup Sequence

A station must be addressed, parameterized and accepted before it reaches normal data exchange. Failure at one stage explains why a device can be electrically visible yet absent from the cyclic image.

Explanation 02

Acyclic Records

DP-V1 read and write requests access indexed device records outside the cyclic I/O bytes. This keeps parameter access from changing the size or position of the process-data map.

Explanation 03

Diagnostic Separation

Network, module and slave diagnostics describe different layers. Reading the master indicators together with the affected station record prevents a bus-cable fault from being confused with rejected slave parameters.

When a configured station does not enter data exchange, compare the physical address, bus termination and configured module identity before changing the controller memory map.

05 · FAQ

Model FAQs

How many slave devices can IC695PBM300-EC manage on one PROFIBUS network?

IC695PBM300-EC can manage up to 125 configured slaves, but the usable design must also remain inside the total and per-slave process-data limits. Count both stations and mapped bytes when checking the network.

What should be checked when IC695PBM300-EC sees a slave but does not exchange data?

For IC695PBM300-EC, verify that the station address, device identity, parameter record and module layout match the physical slave. A visible node is not enough if parameterization or the configured I/O structure is rejected.

Can IC695PBM300-EC perform acyclic parameter access while cyclic I/O is running?

Yes. IC695PBM300-EC supports DP-V1 read, write and alarm services in addition to the cyclic DP exchange, keeping device records separate from the normal process image.

Why must the byte count be reviewed before loading an IC695PBM300-EC configuration?

IC695PBM300-EC applies a 244-byte input and output ceiling to each slave and a 3,584-byte ceiling to each complete network direction. Both levels must fit.

Which controller condition is required before IC695PBM300-EC is added?

The host RX3i CPU used with IC695PBM300-EC needs firmware 2.9 or later and a compatible Universal Backplane position. The module is not a Series 90-30 serial-expansion device.

How do the front indicators help isolate an IC695PBM300-EC problem?

The IC695PBM300-EC indicators separate module status from network and communication activity. Read them together with the configured slave status so a local module condition is not mistaken for a fieldbus wiring fault.

06 · MOORE

Brand Supply Scope

Moore Automation

https://www.mvme.cn/

Moore Automation handles enquiries across established industrial automation families. Requests are recorded by manufacturer and exact model so a GE Fanuc controller item is not confused with a similarly numbered part from another platform.

Control PlatformsGE Fanuc, ABB and Siemens controller families
Process SystemsYokogawa and Emerson system components
Motion & DrivesServo, drive and motion-control product lines
IdentificationManufacturer and complete model kept together
www.mvme.cn
07 · SELECT

Comparable Models

Siemens3RV1935-1A
OmronCQM1-CPU11-9
SICKUM18-21212C211
ABBCA5-10
Mitsubishi ElectricA1SX81
Rockwell Automation1734-OE2C
Honeywell2NT1-3
General ElectricIC693ACC303
BeckhoffKL1104
Phoenix Contact2726311
Siemens6SN1114-0AA01-0AA0
OmronG2R-1-SND(S)
SICKS30A-4011BA
ABBCAF6-20M
Mitsubishi ElectricGT1675M-STBD
Rockwell Automation193-ESM-VIG-30A-C55
Honeywell31074387
General ElectricMDS-SD9
BeckhoffKL2114
Phoenix Contact2313287
Siemens6ES7421-1BL01-0AA0
OmronCN401
SICKS30B-3011GB
ABBLPUC1
Mitsubishi ElectricGT2510-VTBA
Rockwell Automation845-CA-D-25
HoneywellSC-TEPR01
General ElectricMCAG14SSBG5600A
BeckhoffKL9010
Phoenix Contact2861331
Siemens6ES7193-4JA00-0AA0
OmronE39-R1
SICKS32B-3011BA
ABBGHS2701916R0001
Mitsubishi ElectricGT2508-VTBD
Rockwell Automation1492-CB2-DG100
HoneywellTP-OPADP1-201
General ElectricIC695ETM001-KAAA
BeckhoffKL9186
Phoenix ContactPLC-BSC-24DC
Siemens6ES7195-1JA00-0XA0
OmronG2RV-SL701
SICKS30B-2011BA
ABBDS651
Mitsubishi ElectricFX5-80SSC-G
Rockwell Automation1485P-P8T5-T5
HoneywellLS4YAC1A
General ElectricIC200ALG322-H
BeckhoffKL9100
Phoenix ContactUK5-HESI
SiemensPT17040
OmronMY4NJ
SICKS32B-2011BA
ABB1SAR212100R0511
Mitsubishi ElectricMR-JE-200B
Rockwell Automation1784-CF64
HoneywellFDAP3P
General ElectricA02B-0029-K891
BeckhoffKL9187
Phoenix Contact2961192

Contact Our Team

Moore Automation · Send the complete manufacturer, model and destination details through the contact channel that suits your request.

ManagerLeonia

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.