Terminal entry
Each enabled field loop reaches its assigned terminal pair before it enters the analogue front end.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | GE Fanuc IC695ALG616-LF 16-Channel Analog Input Module |
| Item NO. | 2945585 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | GE |
| Brand | GE |
| Creation Time | 2026-11-27 |
GE Fanuc IC695ALG616-LF is a sixteen-channel analogue current and voltage input module for the PACSystems RX3i universal backplane. It receives field signals at the terminal block, converts each enabled input into controller data and reports module and channel conditions through the RX3i fault system.
Each channel of IC695ALG616-LF can be configured for a supported current or voltage range. Conversion, scaling and alarm comparison take place inside the module, so the CPU receives both the selected process value and the diagnostic status associated with that physical channel.
The IC695ALG616-LF field terminals share common and return paths according to the selected single-ended or differential wiring arrangement. Terminal-block detection, channel status words and open-wire or range diagnostics keep wiring faults separate from ordinary changes in the measured process.
The module converts field signals into controller data without merging the identity of individual channels.
Each enabled field loop reaches its assigned terminal pair before it enters the analogue front end.
The configured current or voltage range defines the electrical interpretation used for that channel.
The converter produces a digital channel value and applies the configured scaling relationship.
The completed value and its channel status travel together across the RX3i backplane.
This sequence keeps the physical terminal, selected electrical range, converted value and controller reference associated with the same channel. A commissioning check can therefore follow one signal from its field loop to the value used by the application.
Diagnostic information follows a separate path so the controller can distinguish a process value from an unhealthy signal circuit.
Supported current ranges can identify a broken or incomplete loop rather than reporting it as an ordinary low value.
Under-range and over-range conditions remain tied to the affected channel.
The module detects whether the terminal block is present and reports the hardware condition.
Internal conversion and backplane faults are exposed through module status and controller diagnostics.
The reported measurement and its diagnostic condition must be evaluated together. That separation prevents a wiring break, missing terminal block or conversion fault from being treated as an ordinary change in the measured process.
Keep the full IC695ALG616-LF code on the enquiry and receiving record. The LF revision does not justify changing the channel ranges or wiring data published for the IC695ALG616 base module.
Compare the configured range with the actual transmitter type, then verify the channel terminals, common path and loop supply. Use the channel status word to separate an open loop from a valid low process value.
The process value and diagnostic bits are reported separately. A signal can remain inside the numeric range while the module detects terminal, loop or internal conditions that require attention.
Disable channels that are not wired or configure them consistently with the project. Leaving an unwired channel enabled can create open-wire or range indications that look like active field faults.
Retain the terminal assignment, current-versus-voltage selection, range, scaling, alarms and single-ended or differential arrangement for every channel.
Review the enabled-channel configuration and the module update behavior in the controller project. Test all used channels with traceable input points before relying on the live process values.
Moore Automation records the complete manufacturer label, quantity and terminal-block requirement for each analogue-module enquiry. Nearby RX3i revisions remain on separate records.