Product Name GE Fanuc IC630PWR320 / IC630PWR324 Series Three Remote Power Supply Module
Item NO. 2906805
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category GE
Brand GE
Creation Time 2026-09-09

GE Fanuc IC630PWR320 / IC630PWR324 Series Three Remote Power Supplies
Series Three Remote I/O Power

GE Fanuc IC630PWR320 / IC630PWR324 Series Three Remote Power Supplies

High-capacity remote Series Three power supplies for 115/230 Vac or 24 Vdc source systems.

IC630PWR320High-capacity remote I/O power supply
IC630PWR324High-capacity remote I/O power supply

Product Description

IC630PWR320 and IC630PWR324 are high-capacity Series Three power supplies intended for remote I/O base operation. IC630PWR320 accepts 115/230 Vac; IC630PWR324 is the 24 Vdc input version. Both provide the same listed +5 V and +12 V load-unit capacity to the remote base.

The remote supply adds control and indication functions required away from the CPU base. The ac version provides RUN terminals and normally-open fault-relay contacts that can be incorporated into external indication or alarm circuits. Those terminals must be treated as part of the field wiring record, not as ordinary backplane points.

A remote-base replacement requires more than matching voltage. Preserve base address and I/O cable routing, supply revision, mode/control wiring, alarm-contact use and all module load units. Validate the remote communications path and every mapped I/O point after power is restored.

Technical Specifications

Specification IC630PWR320 IC630PWR324
Brand GE Fanuc
Product Type High-capacity remote I/O power supply
Country United States
System Family Series Three PLC
Input Source 115/230 Vac, 50/60 Hz 24 Vdc
Rack Role Remote Series Three I/O base
+5 V Capacity 300 load units (1 unit = 10 mA)
+12 V Capacity 200 load units (1 unit = 10 mA)
Remote Control RUN terminals with normally-open operating contacts Remote-base control according to 24 Vdc supply hardware
Fault Indication Normally-open fault-relay contacts for external alarm use Remote supply status/fault function; preserve installed wiring
Integration Remote base, I/O expander/CPU cable path and assigned I/O references
Installation Record Input wiring, alpha revision, RUN/fault contacts, base address, cable path and module inventory

Remote I/O Monitoring and Control

Series Three Base Module Outline and Power-Supply Mounting Envelope
Series Three Base Module Outline and Power-Supply Mounting Envelope · click to enlarge

Both supplies deliver 300 units at +5 V and 200 units at +12 V to a remote Series Three base.

IC630PWR320 is selected for 115/230 Vac sites; IC630PWR324 provides the corresponding 24 Vdc input option.

On the ac remote supply, RUN and fault-relay contacts can signal controller state to external alarm or interlock circuits.

Remote power health must be checked together with the I/O communication cable, base addressing and mapped field points because a healthy dc rail alone does not prove remote I/O operation.

Remote Base Installation

Document the station

Record remote-base number, cable route, supply revision, input source, module list and any RUN/fault contact wiring.

Remove all energy

Isolate the supply input and every field circuit that can backfeed terminals in the remote base.

Install and reconnect

Match ac selection for IC630PWR320 or dc polarity for IC630PWR324, then restore I/O cable and alarm/control conductors exactly.

Prove the station

Confirm supply status, fault-contact behavior, remote communications and every mapped input/output point before returning the process to automatic control.

Product FAQ

What is the input difference between IC630PWR320 and IC630PWR324?

IC630PWR320 uses 115/230 Vac at 50/60 Hz; IC630PWR324 is the 24 Vdc remote supply.

Are IC630PWR320 and IC630PWR324 local CPU-base supplies?

They are identified as high-capacity remote I/O power supplies. Use IC630PWR310 or IC630PWR314 for the corresponding local high-capacity role.

What do the IC630PWR320 RUN contacts indicate?

The normally-open contacts are active in the documented RUN, RUN 1 or TEST modes and open when the operating condition is lost or an error is detected.

What must be preserved when replacing IC630PWR320 or IC630PWR324?

Preserve input wiring, base address, cable path, module load, supply revision and all RUN/fault contact connections.

How is a remote station accepted after installing IC630PWR320 or IC630PWR324?

Check power and fault behavior, verify the remote communication path, then test every assigned input and output with the process safely controlled.

Moore Automation warehouse, service or company activity scene
Moore Automation

Industrial Automation Business Range

Moore Automation supplies PLC and DCS hardware, I/O modules, drives, operator interfaces, communication equipment and power components used across industrial control applications.

The company's published service commitments are 100% original products, fast delivery, a one-year warranty and a 12-hour online response.

Contact

ManagerLeonia
WhatsApp+8618030175807

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.