Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>GE>GE Fanuc IC630MDL326 / IC630MDL327 Series Three AC Input Module
GE Fanuc IC630MDL326 / IC630MDL327 Series Three AC Input Module

GE Fanuc IC630MDL326 / IC630MDL327 Series Three AC Input Module Item NO.: 2906807

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name GE Fanuc IC630MDL326 / IC630MDL327 Series Three AC Input Module
Item NO. 2906807
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category GE
Brand GE
Creation Time 2026-09-09

GE Fanuc IC630MDL326 / IC630MDL327 Series Three AC Input Modules
Series Three AC Inputs

GE Fanuc IC630MDL326 / IC630MDL327 Series Three AC Input Modules

115 VAC isolated input230 VAC input optionSeparate order numbers

Product Overview

GE Fanuc IC630MDL326 and IC630MDL327 are Series Three discrete AC input modules identified for different voltage and input arrangements. IC630MDL326 provides eight isolated 115 VAC input circuits. IC630MDL327 is listed as a 16-point 230 VAC input module.

For IC630MDL326, each input has two field terminals so its eight circuits can use separate user-supplied AC sources. The isolation description refers to separation between the module input circuits relative to their AC sources.

The GE ordering entry for IC630MDL327 identifies its 230 VAC and 16-point configuration; this page does not extend that entry with specifications from another model.

8Isolated AC inputs on IC630MDL326
16230 VAC inputs on IC630MDL327
97–132VAC source range for IC630MDL326
1:1Separate field pair per IC630MDL326 input

Product Specifications

Specification Details
Brand GE Fanuc
Model IC630MDL326 / IC630MDL327
Product Type Series Three AC Input Modules
Country of Origin United States
Specification IC630MDL326 IC630MDL327
Product type Isolated AC input module 230 VAC input module
Input points 8 isolated circuits 16 points
Voltage classification 115 VAC 230 VAC
Platform GE Series Three GE Series Three

IC630MDL326 input data

Parameter Details
User power voltage 97–132 VAC, 50/60 Hz
ON voltage 80 VAC minimum
OFF voltage 20 VAC maximum
ON delay 10–40 ms typical
OFF delay 10–60 ms typical
Internal power 5 VDC, 50 mA
Indicators 8 LEDs, one per input circuit

Input Isolation Strategy

Independent field-source connections

IC630MDL326 gives each of its eight input circuits two field terminals. This permits separate AC power sources, including different phases, to be assigned to individual inputs.

  • Typical input devices include limit switches, pushbuttons, selector switches and relay contacts.
  • Each circuit receives one discrete ON/OFF signal.
  • The field sources are supplied by the user.
GE Series Three IC630MDL326A isolated AC input wiringClick to enlarge
GE Series Three IC630MDL326A isolated AC input wiring

System Integration Notes

Keep the voltage class tied to the order number

IC630MDL326 and IC630MDL327 are not the same voltage variant. The exact model number must be matched to the intended field signal level and terminal plan.

  • Use IC630MDL326 data only for the isolated 115 VAC eight-circuit module.
  • Use the IC630MDL327 identity for the 230 VAC 16-point version.
  • Do not import terminal or delay data from one model into the other.
System Integration Notes technical illustrationClick to enlarge
System Integration Notes technical illustration

Frequently Asked Questions

Which Series Three input roles are assigned to IC630MDL326 and IC630MDL327?

IC630MDL326 is the eight-circuit isolated 115 VAC input module, while IC630MDL327 is the 16-point 230 VAC input module.

Why are IC630MDL326 and IC630MDL327 not direct voltage substitutes?

Their voltage classes, point counts and terminal arrangements differ, so the complete order number must match the field circuit.

How are the field sources handled by IC630MDL326 and IC630MDL327?

IC630MDL326 provides a separate terminal pair for each of its eight isolated inputs; IC630MDL327 must follow its own 230 VAC connection plan.

Which timing data apply when comparing IC630MDL326 and IC630MDL327?

The listed 10–40 ms ON and 10–60 ms OFF values apply to IC630MDL326; they are not transferred to IC630MDL327.

What identification should be checked when ordering IC630MDL326 and IC630MDL327?

Check the complete faceplate order number together with the required voltage class and input count.

Moore Automation warehouse and industrial component operations

Industrial Control Coverage

Moore Automation works across DCS, PLC, RTU, IPC and HMI component categories for industrial control requirements.

Its documented scope also includes industrial low-frequency screens, AnyBus gateways, industrial SCSI hard drives and related ancillary control products.

Contact Information

ManagerLeonia
WhatsApp+8618030175807

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.