Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>GE>GE Fanuc IC200ALG326K 8-Channel Current Output Module
GE Fanuc IC200ALG326K 8-Channel Current Output Module

GE Fanuc IC200ALG326K 8-Channel Current Output Module Item NO.: 2944603

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name GE Fanuc IC200ALG326K 8-Channel Current Output Module
Item NO. 2944603
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category GE
Brand GE
Creation Time 2026-11-24

GE Fanuc IC200ALG326K 8-Channel Current Output Module
AO13-bit current output

GE Fanuc · VersaMax

GE Fanuc IC200ALG326K 8-Channel Current Output Module

K revision · eight current-sourcing outputs · carrier-mounted I/O

8output channels
13bit conversion
15ms update rate
01

Product Introduction

GE Fanuc IC200ALG326K is the K-revision form of the VersaMax IC200ALG326 analog current output module. It accepts eight output words from a VersaMax CPU or network interface unit and converts them into eight single-ended current-sourcing channels for field loads.

The eight outputs of IC200ALG326K operate as one group. A field-terminal jumper selects 4-20 mA or 0-20 mA for the group, while the external 18-30 VDC source supplies the field side; the 5 V backplane supply powers the module logic, so field power and logic power remain distinct.

For IC200ALG326K, a second jumper determines whether outputs hold their last commanded values or move to the low end of range when backplane communication stops or the PLC is stopped. FLD PWR and OK indicators separate field-side supply status from backplane power status, and loss of user-side power is reported as a module diagnostic.

IC200ALG326K technical illustration extracted from the product manual
02

Technical Information

Brand
GE Fanuc
Model
IC200ALG326K
Product name
13-bit, 8-channel analog current output module
Series
VersaMax
Revision marking
K
Output channels
8 single-ended, one group
Output ranges
4-20 mA or 0-20 mA
External supply
18-30 VDC including ripple
Backplane current
50 mA maximum at 5 V
Load resistance
0-800 Ω maximum
Capacitive load
0.1 µF maximum
Inductive load
0.5 H maximum
Accuracy at 25 °C
±0.3% typical; ±0.5% maximum of full scale
Resolution
2.5 µA increments; about 12.7 bits at 4-20 mA and 13 bits at 0-20 mA
Update rate
15 ms maximum
Output default
Hold last state or low end of range
Isolation
250 VAC continuous; 1500 VAC for 1 minute
Module ID
FFFF9480
03

Current Command Path

IC200ALG326K carries each controller command through three distinct stages before current reaches the load.

Backplane words

Backplane words

The CPU or NIU writes eight ordered output words. Each word belongs to one physical channel, so channel mapping in the project must follow the carrier terminal assignment.

Group scaling

Group scaling

The range jumper applies to the complete eight-channel group. The controller scale and jumper position must agree before the numeric word can represent the intended loop current.

Field delivery

Field delivery

The output stage sources current from the external field supply through the connected load. The permitted resistance depends on available field voltage and the 20.38 mA overrange current.

04

Field Power and Output Defaults

IC200ALG326K separates normal command processing from the behavior used when controller communication is no longer available.

Power boundaryHold selectionLow-end selection

Power boundary

Backplane power keeps module logic active, but output current requires the 18-30 VDC field source. FLD PWR can therefore identify a missing field-side supply even when OK remains on.

Hold selection

With the hold jumper open, the last output values remain until new data arrives or field power is removed. This preserves the most recent commanded values during a controller-side interruption.

Low-end selection

With the default jumper installed, the outputs move to the low end of the selected range. For 4-20 mA that means 4 mA; for 0-20 mA it means 0 mA.

05

Frequently Asked Questions

How should an IC200ALG326K replacement be documented?

Record the IC200ALG326K suffix, carrier number, range jumper, default jumper, field voltage, channel-to-terminal mapping and representative output words before removal.

Why can all IC200ALG326K outputs sit near the wrong end of range?

For IC200ALG326K, compare the group range jumper with project scaling first. A 0-20 mA jumper used with 4-20 mA logic changes the relationship for all eight channels at once.

How can an IC200ALG326K channel be separated from a load problem?

Command a controlled value on IC200ALG326K, measure current at the carrier, and compare it with a known load or current meter while observing field power and total loop resistance.

What should be checked when IC200ALG326K has OK on but no output current?

On IC200ALG326K, verify the FLD PWR indicator, measure the external 18-30 VDC source at DC+ and DC-, and confirm load continuity before treating the logic side as faulty.

What matters when moving IC200ALG326K to another carrier?

For IC200ALG326K, preserve the A/B terminal functions, shield points, jumper positions and DC polarity; the two-row and three-row carriers arrange those functions differently.

Why does IC200ALG326K retain current after the PLC stops?

IC200ALG326K retains the last values when the hold-last-state jumper selection is active. Check the B3 hold-jumper circuit against the intended stop behavior.

06

Customer Support

Moore Automation

Moore Automation keeps an enquiry record tied to the manufacturer, full model, hardware suffix, carrier, quantity and destination. For IC200ALG326K, range and default-jumper details can remain attached to the commercial request without being treated as a replacement assumption.

Exact suffix confirmation
Carrier and document coordination
One structured enquiry record
Moore Automation company service image 1
07

Selected Products

Rockwell Automation1794-ACN15
Rockwell Automation1794-ACNR15
Rockwell Automation1794-ASB
Rockwell Automation1794-IA16
Rockwell Automation1794-IB16
Rockwell Automation1794-IB32
Rockwell Automation1794-IE8
Rockwell Automation1794-IF4I
Rockwell Automation1794-IF8IH
Rockwell Automation1794-OB16
Rockwell Automation1794-OB32P
Rockwell Automation1794-OE12
Rockwell Automation1794-OE4
Rockwell Automation1794-OW8
Rockwell Automation2707-L40P1
Rockwell Automation2707-L8P1
Rockwell Automation2707-M485P3
Rockwell Automation2707-MVH232
Rockwell Automation2707-MVP232
Rockwell Automation2707-V40P1
Rockwell Automation2707-V40P2N
ABB3HAC021353-001
ABB3HAC021722-001
ABB3HAC021724-001
ABB3HAC021725-001
ABB3HAC038404-003
ABB3HAC054560-001
ABB3HAC058992-003
Siemens3UA59 40-1J
GEIC5002CA0000-FF
GEIC5002TAW0000
GEIC5002TAW1000
GEIC5002TAW4000
GEIC5002TBW0000
GEIC5005CAC0000
GEIC5005CAC0001
GEIC5005TAW0000
GEIC5005TAW1000
GEIC5005TAW4000
GEIC5005TBW0000
GEIC5008TAW0000
GEIC5008TAW1000
GEIC5008TAW4000
GEIC5008TBW0000
GEIC660CBB903
GEIC660HHM500
GEIC754CSF06CTD
GEIC754VBL06CTD
GEIC754VSB06MTD
Siemens5SM9322-0KK
Siemens6DR5010-0EN01-0AA0
Siemens6ES5464-8MC11
Siemens6ES7953-8LF30-0AA0
Siemens6ES7972-0BB42-0XA0
ABBACS550-01-012A-4
ABBACS550-01-017A-4
ABBACS550-01-045A-4
ABBACS550-01-059A-4
ABBACS550-01-072A-4
ABBACS550-01-096A-4

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.