±0.6 MM THRUST RANGE · 7 M SYSTEM · DIN AND BULKHEAD MOUNT
Complete model · 991-06-70-03-05
01
Product Details
Bently Nevada 991-06-70-03-05 is a 991 two-wire thrust transmitter for a matched 3300 NSv proximity system. Its 06 range field represents the ±0.6 mm axial-displacement span, while 70 selects a 7.0 m system and 03 selects DIN clips with bulkhead screws.
The input path of Bently Nevada 991-06-70-03-05 starts at the 3300 NSv probe and matched extension cable. The integrated Proximitor Sensor conditions the axial signal and the transmitter drives a 4–20 mA process loop for the control system.
Bently Nevada 991-06-70-03-05 also provides a buffered BNC Prox Out, zero and span adjustments, power-up inhibit and Not OK/signal defeat. The final 05 approval field remains part of the exact transmitter record.
02
Specification Summary
Brand
Bently Nevada
Complete model
991-06-70-03-05
Product type
991 two-wire thrust transmitter
Full-scale range
06 = 0.6–0–0.6 mm
System length
70 = 7.0 m
Mounting
03 = DIN clips and bulkhead screws
Approval
05 = multiple approvals
Input
3300 NSv proximity transducer
Output
4–20 mA
Supply
+12 to +35 Vdc
Accuracy
±1.5%
Buffered output
BNC Prox Out
Prox output load
10 kΩ for 10 MΩ load
Not OK current
Below 3.6 mA
Not OK response
Within 100 µs
Recovery time
Within 0.1 s
Humidity
Up to 100%, condensing
Adjustments
Zero and span
Construction
Potted transmitter
Protection
Power-up inhibit
03
Performance Characteristics
Bently Nevada 991-06-70-03-05 uses a defined axial range and loop behavior to represent thrust position in the control system.
01
Axial range
The 06 field on Bently Nevada 991-06-70-03-05 selects the 0.6–0–0.6 mm thrust range.
02
Loop accuracy
The 4–20 mA output of Bently Nevada 991-06-70-03-05 is specified to ±1.5% loop accuracy.
03
Fault response
A Not OK condition is represented below 3.6 mA, with the documented rapid response and recovery behavior.
04
Installation Highlights
The physical installation of Bently Nevada 991-06-70-03-05 combines the 35 mm DIN clips, bulkhead screws and the 7.0 m matched probe system.
01
Mounting hardware
The 03 field gives Bently Nevada 991-06-70-03-05 both DIN-rail clips and bulkhead screws, allowing the selected mounting boundary to be retained.
02
Matched length
The 70 field identifies the 7.0 m 3300 NSv probe and extension-cable system length used by Bently Nevada 991-06-70-03-05.
03
Loop wiring
The +12 to +35 Vdc supply and 4–20 mA loop must be wired with the correct polarity and the transmitter’s PROX OUT kept separate for diagnostics.
05
Frequently Asked Questions
Why can Bently Nevada 991-06-70-03-05 show thrust zero drift?
For Bently Nevada 991-06-70-03-05, check the probe gap, zero/span adjustment and the 7.0 m matched NSv system before changing the control-system zero. Mechanical movement and electrical-length mismatch affect the same displayed value.
What should be checked when Bently Nevada 991-06-70-03-05 reports low loop current?
A Bently Nevada 991-06-70-03-05 loop current below 3.6 mA indicates the Not OK region. Check the probe, extension, transmitter supply and terminal polarity before treating the low current as a negative thrust value.
How does the 03 option affect installation of Bently Nevada 991-06-70-03-05?
The 03 field on Bently Nevada 991-06-70-03-05 provides DIN clips and bulkhead screws. Choose the fixing method that matches the cabinet drawing, but keep the 4–20 mA loop and BNC Prox Out wiring separate.
Why is the BNC Prox Out useful on Bently Nevada 991-06-70-03-05?
The buffered BNC Prox Out on Bently Nevada 991-06-70-03-05 lets a technician observe the dynamic and gap signal while the 4–20 mA loop remains connected to the control input.
How quickly should a Not OK change be visible from Bently Nevada 991-06-70-03-05?
Bently Nevada 991-06-70-03-05 specifies the Not OK current behavior and response timing in the transmitter record. Compare the observed loop transition with the documented response before changing alarm delays in the control system.
Why must the 05 approval field remain with Bently Nevada 991-06-70-03-05?
The final 05 field is part of the complete Bently Nevada 991-06-70-03-05 approval record. Removing it can result in a transmitter with the wrong installation or certification configuration.
Moore Automation supports industrial automation, monitoring and instrumentation enquiries with complete model records and coordinated supply information.
The requested 991-06-70-03-05 record can stay linked to quantities, drawings and shipment details during the enquiry.
Exact model record
The complete 991-06-70-03-05 string stays visible in the enquiry.
Industrial scope
Moore Automation handles automation, monitoring and instrumentation records.
Order traceability
Quantities, drawings and shipment details remain tied to the model record.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.