Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>BENTLY NEVADA>Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 | Orbit 60 240 W AC/DC Industrial Power Supply Module
Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 | Orbit 60 240 W AC/DC Industrial Power Supply Module

Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 | Orbit 60 240 W AC/DC Industrial Power Supply Module Item NO.: 2926050

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 | Orbit 60 240 W AC/DC Industrial Power Supply Module
Item NO. 2926050
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category BENTLY NEVADA
Brand Bently Nevada
Creation Time 2026-10-22

Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 | Orbit 60 240 W AC/DC Industrial Power Supply Variants

Bently Nevada · Orbit 60 external DC supply

Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 | Orbit 60 240 W AC/DC Industrial Power Supply Variants

240 W output24 Vdc adjustableThree approval variants
Product file60X/XPS01240 W industrial power supply00 · 01 · 02 approvals
01

Product Description

Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 identifies the three approval executions of the 240 W industrial power supply used to feed an Orbit 60 PIM with regulated 24 Vdc-class power. Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 accepts a broad AC or DC input range and provides up to 10 A continuously, with a 15 A peak available for four seconds.

Mounted on a 35 mm DIN rail, Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 converts 85 to 264 Vac or 100 to 250 Vdc into an adjustable 23.5 to 28 Vdc output. Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 uses natural convection and provides short-circuit, overload, and overvoltage responses at the power-source boundary before the PIM distributes that power inside the chassis.

The only difference among Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 is the approval field: 60X/XPS01-00 has no hazardous-area certification, 60X/XPS01-01 carries CSA/NRTL/C Class I Division 2, and 60X/XPS01-02 carries the Multi approval set. Electrical output and mechanical form remain shared across Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02.

02

Product Specifications

Technical Item60X/XPS01-0060X/XPS01-0160X/XPS01-02
BrandBently Nevada
Product NameOrbit 60 240 W AC/DC Industrial Power Supply
CountryUnited States
System FamilyOrbit 60 Series
Base Ordering Code60X/XPS01 = 240 W AC/DC industrial power supply
Hazardous-Area Approval00 = No hazardous-area certification01 = CSA/NRTL/C Class I Division 202 = Multi (CSA, ATEX, IECEx)
Rated Output240 W
Output Voltage24 Vdc nominal; adjustable 23.5 to 28 Vdc
Continuous / Peak Current10 A / 15 A for 4 s
Input Voltage85 to 264 Vac or 100 to 250 Vdc
Input Frequency45 to 65 Hz
Typical Efficiency95%
Maximum Inrush30 A at 230 Vac
Operating Temperature−40 to +70 °C
CoolingNatural convection
MountingEN 50022 35 × 15 / 7.5 mm DIN rail
Mass643 g
ProtectionContinuous short-circuit recovery; overload shutdown/restart; overvoltage response at 32 to 35 Vdc
03

AC/DC Power Conversion

Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 converts the available AC or DC source into the regulated 24 Vdc-class supply required at the Orbit 60 power-input boundary.

01 · Accept

Wide-range input

Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 can be supplied from 85 to 264 Vac or 100 to 250 Vdc without changing the 240 W model family.

02 · Regulate

Adjustable 24 Vdc output

Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 provides a 23.5 to 28 Vdc adjustment range for the connection feeding the PIM.

03 · Supply

Continuous and peak current

Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 carries 10 A continuously and permits a 15 A peak for four seconds during a short demand interval.

04

Electrical and Mechanical Protection

Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 combines electronic fault responses with a ventilated DIN-rail enclosure designed for natural-convection cooling.

Short-circuit response

Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 limits a short circuit continuously and returns automatically after the fault is removed.

Overload handling

Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 supplies constant current initially, switches off after the overload interval, and attempts a restart after approximately ten seconds.

DIN-rail airflow

Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 mounts vertically on a 35 mm rail and relies on unobstructed natural convection across its enclosure.

05

Common Questions

How should a buyer choose among the three Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 variants?

Choose within Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 by the required approval: 00 has no hazardous-area certification, 01 carries CSA/NRTL/C Class I Division 2, and 02 carries the Multi approval set. The output rating alone does not distinguish the Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 variants.

Can Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 be connected to either AC or DC input power?

Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 accepts 85 to 264 Vac or 100 to 250 Vdc, but the terminals, protective devices, and isolation method must match the actual source. Do not apply both source types to Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 at the same time.

Why might Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 repeatedly switch off and restart under load?

Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 enters its overload response when the demand exceeds the continuous capability: it supplies constant current, switches off after about four seconds, and retries after roughly ten seconds. Check the connected load and wiring before replacing Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02.

What should be checked if the output from Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 is below the required PIM voltage?

For Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02, measure the output at the supply and at the PIM, check conductor drop and load current, and confirm the adjustment is within 23.5 to 28 Vdc. Do not use the Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 adjustment to hide an overloaded or undersized cable path.

Can two Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 supplies simply be paralleled for higher current?

The Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 description provides the rating for one supply and does not define unrestricted current sharing. Use separate redundant source paths into the PIM arrangement rather than assuming two Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 units can be paralleled for a higher load.

Why does mounting orientation matter for Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02?

Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 relies on natural convection across its DIN-rail enclosure. Keep the specified vertical orientation and airflow clearances so Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 can operate across its stated temperature range without trapped heat.

06

Shipping Services

MOORE AUTOMATION

Moore Automation records packing instructions, destination details and the selected carrier with the product enquiry. Dispatch and tracking information is shared after the carrier accepts the shipment and issues the relevant reference.

PackingProtection selected for the item
Carrier optionsDHL, UPS, FedEx or nominated carrier
Dispatch recordShipment reference retained
TrackingDetails shared when issued
www.mvme.cn
08

Enquiry Information

Discuss 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02Send the required quantity and destination for a model-specific enquiry.
ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.