Wide-range input
Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 can be supplied from 85 to 264 Vac or 100 to 250 Vdc without changing the 240 W model family.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 | Orbit 60 240 W AC/DC Industrial Power Supply Module |
| Item NO. | 2926050 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | BENTLY NEVADA |
| Brand | Bently Nevada |
| Creation Time | 2026-10-22 |
Bently Nevada · Orbit 60 external DC supply
Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 identifies the three approval executions of the 240 W industrial power supply used to feed an Orbit 60 PIM with regulated 24 Vdc-class power. Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 accepts a broad AC or DC input range and provides up to 10 A continuously, with a 15 A peak available for four seconds.
Mounted on a 35 mm DIN rail, Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 converts 85 to 264 Vac or 100 to 250 Vdc into an adjustable 23.5 to 28 Vdc output. Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 uses natural convection and provides short-circuit, overload, and overvoltage responses at the power-source boundary before the PIM distributes that power inside the chassis.
The only difference among Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 is the approval field: 60X/XPS01-00 has no hazardous-area certification, 60X/XPS01-01 carries CSA/NRTL/C Class I Division 2, and 60X/XPS01-02 carries the Multi approval set. Electrical output and mechanical form remain shared across Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02.
| Technical Item | 60X/XPS01-00 | 60X/XPS01-01 | 60X/XPS01-02 |
|---|---|---|---|
| Brand | Bently Nevada | ||
| Product Name | Orbit 60 240 W AC/DC Industrial Power Supply | ||
| Country | United States | ||
| System Family | Orbit 60 Series | ||
| Base Ordering Code | 60X/XPS01 = 240 W AC/DC industrial power supply | ||
| Hazardous-Area Approval | 00 = No hazardous-area certification | 01 = CSA/NRTL/C Class I Division 2 | 02 = Multi (CSA, ATEX, IECEx) |
| Rated Output | 240 W | ||
| Output Voltage | 24 Vdc nominal; adjustable 23.5 to 28 Vdc | ||
| Continuous / Peak Current | 10 A / 15 A for 4 s | ||
| Input Voltage | 85 to 264 Vac or 100 to 250 Vdc | ||
| Input Frequency | 45 to 65 Hz | ||
| Typical Efficiency | 95% | ||
| Maximum Inrush | 30 A at 230 Vac | ||
| Operating Temperature | −40 to +70 °C | ||
| Cooling | Natural convection | ||
| Mounting | EN 50022 35 × 15 / 7.5 mm DIN rail | ||
| Mass | 643 g | ||
| Protection | Continuous short-circuit recovery; overload shutdown/restart; overvoltage response at 32 to 35 Vdc | ||
Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 converts the available AC or DC source into the regulated 24 Vdc-class supply required at the Orbit 60 power-input boundary.
Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 can be supplied from 85 to 264 Vac or 100 to 250 Vdc without changing the 240 W model family.
Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 provides a 23.5 to 28 Vdc adjustment range for the connection feeding the PIM.
Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 carries 10 A continuously and permits a 15 A peak for four seconds during a short demand interval.
Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 combines electronic fault responses with a ventilated DIN-rail enclosure designed for natural-convection cooling.
Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 limits a short circuit continuously and returns automatically after the fault is removed.
Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 supplies constant current initially, switches off after the overload interval, and attempts a restart after approximately ten seconds.
Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 mounts vertically on a 35 mm rail and relies on unobstructed natural convection across its enclosure.
Choose within Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 by the required approval: 00 has no hazardous-area certification, 01 carries CSA/NRTL/C Class I Division 2, and 02 carries the Multi approval set. The output rating alone does not distinguish the Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 variants.
Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 accepts 85 to 264 Vac or 100 to 250 Vdc, but the terminals, protective devices, and isolation method must match the actual source. Do not apply both source types to Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 at the same time.
Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 enters its overload response when the demand exceeds the continuous capability: it supplies constant current, switches off after about four seconds, and retries after roughly ten seconds. Check the connected load and wiring before replacing Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02.
For Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02, measure the output at the supply and at the PIM, check conductor drop and load current, and confirm the adjustment is within 23.5 to 28 Vdc. Do not use the Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 adjustment to hide an overloaded or undersized cable path.
The Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 description provides the rating for one supply and does not define unrestricted current sharing. Use separate redundant source paths into the PIM arrangement rather than assuming two Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 units can be paralleled for a higher load.
Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 relies on natural convection across its DIN-rail enclosure. Keep the specified vertical orientation and airflow clearances so Bently Nevada 60X/XPS01-00 / 60X/XPS01-01 / 60X/XPS01-02 can operate across its stated temperature range without trapped heat.
Moore Automation records packing instructions, destination details and the selected carrier with the product enquiry. Dispatch and tracking information is shared after the carrier accepts the shipment and issues the relevant reference.