Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>B&R>B&R X67AO1223 X67 Analog Output Module
B&R X67AO1223 X67 Analog Output Module

B&R X67AO1223 X67 Analog Output Module Item NO.: 2944308

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name B&R X67AO1223 X67 Analog Output Module
Item NO. 2944308
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category B&R
Brand B&R
Creation Time 2026-11-23

B&R X67AO1223 X67 Analog Output Module

B&R X67 system · four-channel voltage output

B&R X67AO1223 X67 Analog Output Module

Voltage command, output enable and load path

Product Overview

B&R X67AO1223 is a four-channel IP67 analog output module for the X67 system. It converts four 12-bit process values into differential ±10 V signals and connects field actuators through A-coded M12 sockets while exchanging cyclic data and diagnostics over X2X Link.

Each X67AO1223 channel passes the digital command through its D/A converter and output filter before the voltage reaches the external load. The load must remain at or above the specified resistance so the channel stays within its ±10 mA operating current, and the internal current limit protects the stage when the wiring demands more.

An internal enable relay in X67AO1223 holds the output path under module control during startup and error conditions. Separate monitoring of fieldbus and I/O power, reverse-polarity protection and short-circuit-resistant outputs help distinguish a supply problem from a bad command value or an overloaded actuator.

Verified product data

Product Data

Brand B&R
Model X67AO1223
Product Name X67 Analog Output Module
System B&R X67
Channels 4 differential analog outputs
Output Range ±10 V
Resolution 12-bit
Conversion Time 400 µs for all channels
Settling Time Approximately 1 ms
Output Current ±10 mA per channel
Minimum Load Resistance 1 kΩ
Current Limit Approximately ±40 mA
Output Filter 2.5 kHz low-pass
Startup / Error Control Internal output-enable relay
Output Protection Short-circuit resistant
Channel-to-Bus Isolation 500 Veff
X2X Link Connection M12, B-coded
Analog Connections 4 × M12, A-coded
Supply Connections M8
Nominal Supply 24 VDC
Supply Range 18 to 30 VDC
Actuator Supply Capacity 12 W maximum
Degree of Protection IP67
Operating Temperature -25 to 60°C
Dimensions 53 × 85 × 42 mm
Approximate Weight 190 g
Process value to field voltage

Output Signal Path

A cyclic digital command becomes a differential voltage only after conversion, filtering and enable control inside the module.

D/A conversion

Each channel maps its 12-bit process value to the configured bipolar voltage range. Application scaling therefore determines the commanded physical voltage.

Output filtering

The analog low-pass stage limits high-frequency content after conversion. It shapes the electrical output but does not repair unstable command data.

Enable relay

The internal relay controls when the analog stages are connected to the field. Startup and error behavior must be included when the actuator requires a defined inactive state.

Load current and supply diagnosis

Protection and Monitoring

Output load, I/O power and X2X Link state are evaluated separately so a missing voltage can be traced to the correct layer.

Load boundary

A load below 1 kΩ demands more than the rated ±10 mA. The current limiter protects the stage, but the actuator voltage will no longer follow the command.

Supply paths

Fieldbus electronics and I/O power enter through protected supply connections. Their status should be checked before replacing an analog output channel.

Short-circuit response

The output is short-circuit resistant, allowing the wiring fault to be removed before the channel is retested without treating protection as normal operating mode.

Installation and troubleshooting

Questions About This Product

Why does X67AO1223 output less than the commanded voltage?+
Measure the load connected to X67AO1223. A resistance below 1 kΩ can push the channel beyond ±10 mA, causing current limiting even when the process value is correct.
What should be checked if all X67AO1223 channels remain at zero?+
Verify X67AO1223 X2X Link state, module configuration, I/O supply and output-enable condition. Four zero outputs point to a shared control or supply layer before four independent wiring faults.
How can one faulty X67AO1223 channel be separated from an actuator problem?+
Disconnect the load safely and measure the unloaded X67AO1223 channel with a verified command. Then inspect the actuator resistance and cable for a short before reconnecting.
Does X67AO1223 startup behavior need to be tested?+
Yes. Confirm how X67AO1223 uses its internal enable relay during controller startup and communication loss, especially when the actuator requires a defined inactive voltage.
Why can an X67AO1223 value be stable in software but noisy in the field?+
Inspect X67AO1223 differential wiring, shielding, grounding and actuator supply. The output filter cannot remove interference introduced after the M12 connector.
What information is useful when requesting X67AO1223?+
Provide the exact X67AO1223 model, quantity, required ±10 V channels, load resistance, connector scope, supply arrangement and module-label photo.
Company information

Shipping Services

Moore Automation

https://www.mvme.cn/

Moore Automation prepares dispatch information from the confirmed product list. Brand, exact model and quantity are carried into packing references, while separately ordered cables or connectors remain distinguishable from the main device.

Confirmed listPacking starts from reviewed items.
Model retentionFull references remain readable.
Accessory linesAdditional parts stay distinct.
Dispatch checkQuantities can be compared before shipment.
Direct contact

Contact Information

Moore Automationhttps://www.mvme.cn/
ManagerLeonia

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.