Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>B&R>B&R X67AM1323 X67 Analog Mixed I/O Module
B&R X67AM1323 X67 Analog Mixed I/O Module

B&R X67AM1323 X67 Analog Mixed I/O Module Item NO.: 2944310

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name B&R X67AM1323 X67 Analog Mixed I/O Module
Item NO. 2944310
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category B&R
Brand B&R
Creation Time 2026-11-23

B&R X67AM1323 X67 Analog Mixed I/O Module

B&R X67 system · current input and output channels

B&R X67AM1323 X67 Analog Mixed I/O Module

Current-loop acquisition and command output

Product Introduction

B&R X67AM1323 is an IP67 analog mixed I/O module for the X67 system with two 0–20 mA differential inputs and two 0–20 mA outputs. It places current-loop acquisition and current-command generation in one field-mounted station and exchanges their process values, status information and parameters through X2X Link.

On channels 1 and 2, X67AM1323 routes the field current through the differential input stage and 12-bit A/D converter before the value enters the cyclic data image. The two channels are converted within 400 µs, while the 300 Hz input filter, limit functions and channel status help the controller separate normal process movement from an overloaded or incorrectly wired loop.

Channels 3 and 4 of X67AM1323 convert digital commands into 0–20 mA outputs, pass them through short-circuit protection and connect them to the field through an internal enable relay. The module monitors I/O power separately from the channel values, and its M8 supply path feeds the connected sensors and actuators while enforcing the documented summation-current and voltage-drop limits.

Verified product data

Technical Information

Brand B&R
Model X67AM1323
Product Name X67 Analog Mixed I/O Module
System B&R X67
Analog Inputs 2 differential current inputs, 0 to 20 mA
Input Conversion 12-bit; 400 µs for both inputs
Input Load <300 Ω
Input Filter 300 Hz cutoff; 40 dB slope
Analog Outputs 2 current outputs, 0 to 20 mA
Output Conversion 12-bit; 400 µs for both outputs
Output Settling Time Approximately 1 ms
Maximum Output Load 400 Ω per channel
Output Protection ±40 mA current limiting; short-circuit proof
Output Enable Internal relay for startup and errors
Electrical Isolation Channels isolated from bus; not isolated channel-to-channel
Connections X2X Link: M12 B-coded; I/O: 4 × M12 A-coded; supply: M8
Supply 24 VDC nominal; 18 to 30 VDC range
Sensor / Actuator Supply 0.5 A and 12 W maximum
Protection and Temperature IP67; -25 to 60°C operation
Dimensions and Weight 53 × 85 × 42 mm; approximately 175 g
Field current to controller data

Current Input Acquisition

The two input channels combine loop wiring, differential measurement and filtering before their values enter the cyclic process image.

Differential loop path

Each transmitter current returns through its assigned M12 pair instead of using chassis ground as the measurement conductor. The input load and loop supply must be included in the available voltage calculation.

Conversion and scaling

The A/D converter maps 0–20 mA to the documented integer range. Application scaling turns that integer into engineering units without changing the electrical loop range.

Filter and limit status

The 300 Hz input filter acts before software evaluation, while configurable limits add channel status alongside the measured value. Neither function can restore a loop with reversed polarity or insufficient supply.

Controller command to field current

Output Control and Protection

The two output channels generate current commands through independent converters while sharing the module supply and enable conditions.

Command conversion

Each 12-bit command becomes a 0–20 mA output through its D/A path. The receiving load and cable resistance must keep the channel within the 400 Ω load boundary.

Enable relay behavior

The internal relay controls when channels 3 and 4 are connected during startup and error handling. A valid process command therefore does not by itself prove that the field output is enabled.

Protected supply path

Short-circuit protection, current limiting and I/O-supply monitoring protect the shared power path. Channel faults and an I/O-supply fault should be diagnosed as separate layers.

Installation and troubleshooting

Frequently Asked Questions

What should be copied before replacing X67AM1323?+
Record the X67AM1323 X2X Link position, input scaling, filter and limit settings, output scaling, startup behavior and M12 wiring. Photograph the M8 supply connections before disconnecting the module.
Why can an X67AM1323 input remain at zero with a powered transmitter?+
Check the X67AM1323 current-loop polarity, transmitter supply, M12 pins and total loop voltage. The transmitter can have local power while no current crosses the differential input load.
How should an X67AM1323 output that cannot reach 20 mA be diagnosed?+
Measure the field load and cable resistance connected to X67AM1323. If the total exceeds 400 Ω or the I/O supply lacks voltage headroom, the commanded current cannot be maintained across the load.
Can X67AM1323 input and output channels share an external return without review?+
Do not assume every return can be combined around X67AM1323. Follow the documented M12 pairs, remember that channels are isolated from the bus but not from one another, and check the field-device grounding plan.
Which condition can keep X67AM1323 outputs inactive during startup?+
The internal enable relay of X67AM1323 can hold channels 3 and 4 disconnected until the module reaches its defined state. Verify I/O power, X2X Link status and startup parameters before replacing the output load.
What information belongs in an X67AM1323 enquiry?+
Provide the complete X67AM1323 model, quantity, two input-loop types, two output loads, supply arrangement, connector scope and module-label photo. Keep the current ranges and channel assignments with the request.
Company information

Obsolete Parts Support

Moore Automation

https://www.mvme.cn/

Moore Automation keeps discontinued and current automation references separated by complete manufacturer model. A requested legacy module remains tied to its original suffix, connection scope and quantity so a nearby current product is not recorded as an automatic replacement.

Legacy identityOriginal model strings remain unchanged.
Variant controlNear matches stay on separate lines.
Connection scopeRequired plugs and cables remain visible.
Record continuityThe reviewed identity follows dispatch.
Direct contact

Contact & Enquiry

Moore Automationhttps://www.mvme.cn/
ManagerLeonia

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.