Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>B&R>B&R X20DO2322 X20 Digital Output Module
B&R X20DO2322 X20 Digital Output Module

B&R X20DO2322 X20 Digital Output Module Item NO.: 2942451

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name B&R X20DO2322 X20 Digital Output Module
Item NO. 2942451
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category B&R
Brand B&R
Creation Time 2026-11-18

B&R X20DO2322 X20 Digital Output Module
X20Output

Digital I/O / Source Output

B&R X20DO2322 X20 Digital Output Module

2source outputs
24 VDC
01

Product Summary

B&R X20DO2322 is a two-channel digital output module for the B&R X20 control and I/O system. It converts output commands from the X20 bus into two 24 VDC source outputs, allowing the controller to switch field actuators through independently commanded DO1 and DO2 channels.

The terminal arrangement on X20DO2322 places an output, 24 VDC and GND connection on each side for three-wire actuator wiring. When a channel is commanded on, the high-side FET applies the actuator supply to the output; the connected load returns through GND, while the auxiliary 24 VDC and GND contacts distribute the same supply path for wiring.

During operation, X20DO2322 compares each target state with the measured output state and reports short circuit, overload, missing I/O power or an externally driven inactive channel. If master communication stops, the configured OSP behavior either retains the last valid state or applies a predefined two-bit output pattern until the OSP state is explicitly cleared.

02

Specification Details

Brand B&R
Model X20DO2322
Product Name X20 Digital Output Module
Country Austria
Output Quantity 2 digital outputs
Output Stage Current-sourcing FET
Nominal Voltage 24 VDC
Switching Voltage 24 VDC -15% / +20%
Nominal Output Current 0.5 A per channel
Total Nominal Current 1 A for the module
Connection Type 3-wire connection
Output Protection Thermal shutdown for overcurrent or short circuit
Output Monitoring Target/actual output comparison with 10 ms delay
Switching Delay <300 us for 0 to 1 and 1 to 0
Electrical Isolation Channels isolated from the X20 bus
Operating Temperature -25 to 60°C horizontal; -25 to 50°C vertical
Degree of Protection IP20
Required Station Parts X20BM11 bus module and X20TB06 or X20TB12 terminal block, ordered separately
03

Product Functions

The X20DO2322 data path separates controller mapping, high-side switching and the response used when normal communication is no longer available.

01 / MAP

Cycle-related output transfer

The two commanded bits are transferred to the output channels with a fixed offset of less than 60 us relative to the network cycle. Automation Studio can present them as two individual data points or as one packed USINT, so application logic and I/O mapping must use the same representation.

02 / SWITCH

Source-output load path

Logic drives a high-side FET between the 24 VDC supply and each output terminal. A field load is therefore connected from DO1 or DO2 to GND; the output applies the positive supply while the return conductor closes the actuator circuit.

03 / FALLBACK

Defined OSP response

OSP can retain the last valid value or replace it with a configured static pattern when master communication is interrupted. The module continues using that response after communication is restored and leaves OSP only when OSPValid is transferred again.

04

Diagnostics and Protection

Command, supply, output driver and field wiring are evaluated along the same output path, allowing a status result to show where the requested state was not achieved.

01 / MONITOR

Target versus actual state

Each channel compares the requested state with the monitored output state. A change resets monitoring for that output, and a persistent mismatch is reported after the documented 10 ms delay through software and the module indicators.

02 / PROTECT

Overcurrent response

The output stage uses thermal shutdown for overload or short circuit. After shutdown it attempts to switch on again after approximately 10 ms, with the exact interval influenced by module temperature; the field fault must be removed before normal operation can remain stable.

03 / INDUCTIVE

Inductive-load energy

An internal freewheeling path limits the energy released when an inductive load is switched off. The permitted cycle rate still depends on coil resistance, inductance and switching voltage, and an external inverse diode is required when the published operating-cycle boundary is exceeded.

05

Questions & Answers

How should a field load be wired to X20DO2322?

X20DO2322 uses source outputs: connect the load between DO1 or DO2 and GND, then provide the module actuator path with 24 VDC and GND. Keep the channel current and the combined module current within their documented limits.

Why can X20DO2322 show an active command while the actuator remains off?

X20DO2322 compares the commanded state with the output state. Check the actuator supply, GND return, terminal seating and load wiring; the status bit also reports a channel switched on without I/O power.

What should be checked after X20DO2322 reports an overload?

When X20DO2322 reports overload or short circuit, remove the field fault and check the load current before re-enabling the channel. The thermal output stage attempts to switch on again after approximately 10 ms, with timing dependent on module temperature.

What happens to X20DO2322 outputs if communication with the master stops?

In the X20DO2322 OSP function model, the configured response can retain the last valid output state or apply a defined static pattern. The OSP state remains active until communication returns and OSPValid is set again.

How are the two X20DO2322 outputs mapped in Automation Studio?

X20DO2322 can expose DO1 and DO2 as individual data points or pack both bits into one USINT through the Packed outputs setting. The project mapping must match the format expected by the application logic.

Which station parts are needed to install X20DO2322?

X20DO2322 requires a separately ordered X20BM11 bus module and either an X20TB06 or X20TB12 terminal block. The module is designed for the 6-pin block, while the 12-pin block can also be used for logistical consistency.

06

Reasons to Choose Us

Moore Automation

https://www.mvme.cn/

Moore Automation organizes industrial automation enquiries around the complete manufacturer name, model, suffix, requested condition and quantity. The same item identity is retained while technical documents, commercial terms and shipment information are reviewed.

Exact-model reviewNameplate strings, suffixes and requested revisions remain attached to the enquiry.
Multi-brand scopePLC, DCS, drive, monitoring and distributed I/O hardware can be handled in one request.
Clear commercial recordCondition, quantity, availability and delivery terms are returned against the confirmed part.
Order coordinationPacking, destination and tracking details remain linked to the same order record.

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.