Rear thermal interface
8BVI0028HCS0.000-1 transfers inverter loss through the rear plate. Scratches or poor contact at this surface interrupt the intended heat path.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | B&R Industrial Automation 8BVI0028HCS0.000-1 ACOPOSmulti Inverter Module |
| Item NO. | 2944578 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | B&R |
| Brand | B&R |
| Creation Time | 2026-11-24 |
ACOPOSmulti Inverter Module
B&R Industrial Automation 8BVI0028HCS0.000-1 is a single-axis ACOPOSmulti inverter module for cold-plate or feed-through mounting. It takes 750 VDC and 25 VDC from the ACOPOSmulti backplane, processes network and encoder data, and supplies one protected three-phase motor connection.
The motor stage of 8BVI0028HCS0.000-1 provides 3.8 A continuous current and 7.6 A peak current. Two plug-in slots accept the selected feedback or I/O modules, while POWERLINK node switches, enable and trigger inputs, brake control and a temperature-sensor connection organize the control side of the axis.
Heat from 8BVI0028HCS0.000-1 passes through its rear mounting surface into the cold plate or through the mounting panel in feed-through form. The permitted mounting orientations and flat thermal interface therefore belong to the power path, while status groups on the black cover identify supply, network, encoder and inverter conditions.
| Attribute | 8BVI0028HCS0.000-1 |
|---|---|
| Brand | B&R Industrial Automation |
| Product Name | ACOPOSmulti single-axis inverter module |
| Country | Austria |
| Mounting | Cold plate or feed-through |
| DC-bus voltage | 750 VDC nominal |
| Motor connections | 1 |
| Continuous motor current | 3.8 A |
| Peak motor current | 7.6 A |
| Switching frequencies | 5 / 10 / 20 kHz |
| Plug-in slots | 2 |
| 24 V supply | 25 VDC ±1.6% |
| Motor cable length | Maximum 25 m |
| Temperature-sensor inputs | 1 |
| Degree of protection | IP20 |
| Dimensions | 53 × 317 × 212/209 mm |
The mounting surface is part of the thermal route and must remain distinct from the front wiring area.
8BVI0028HCS0.000-1 transfers inverter loss through the rear plate. Scratches or poor contact at this surface interrupt the intended heat path.
8BVI0028HCS0.000-1 permits vertical hanging and horizontal face-up positions; the standing horizontal position is excluded.
The current capability of 8BVI0028HCS0.000-1 changes with switching frequency, coolant or ambient temperature and installation elevation.
Network identity, feedback selection and motor terminals are separate configuration layers.
Two hexadecimal switches behind the cover set the POWERLINK node number for 8BVI0028HCS0.000-1 before network operation.
The plug-in modules in SLOT1 and SLOT2 determine which encoder or additional I/O signals 8BVI0028HCS0.000-1 can process.
Enable, trigger, brake and temperature-sensor circuits enter their control connectors, while U, V, W and PE leave 8BVI0028HCS0.000-1 at the motor terminal.
The rear surface of 8BVI0028HCS0.000-1 transfers heat to the cold plate or mounting panel, so surface condition and mounting pressure affect the thermal path.
For 8BVI0028HCS0.000-1, inspect backplane supply, the two hexadecimal node switches, POWERLINK status indicators and the network connection before changing axis parameters.
The fitted plug-in module defines the encoder interface for 8BVI0028HCS0.000-1, so record both slot codes with the base-unit code.
For 8BVI0028HCS0.000-1, compare motor current and overload duration with switching frequency, thermal conditions and the selected mounting method.
No. 8BVI0028HCS0.000-1 permits hanging vertical or horizontal face-up mounting, but the standing horizontal orientation is not permitted.
Include the full 8BVI0028HCS0.000-1 code, mounting method, plug-in modules, node setting, motor current, brake and feedback details, and plate photographs.
Moore Automation handles enquiries for PLC, DCS, motion, monitoring and industrial-control components from established manufacturers. Each line item is recorded by complete manufacturer code rather than by series shorthand.
A named account contact coordinates requested documents, quotation information and shipment updates while keeping unrelated brand and model records separate.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found