Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>AB>Allen-Bradley 2198-E1015-ERS / 2198-E1020-ERS / 2198-E2030-ERS Kinetix 5100 200 V-class Servo Drives
Allen-Bradley 2198-E1015-ERS / 2198-E1020-ERS / 2198-E2030-ERS Kinetix 5100 200 V-class Servo Drives

Allen-Bradley 2198-E1015-ERS / 2198-E1020-ERS / 2198-E2030-ERS Kinetix 5100 200 V-class Servo Drives Item NO.: 2911889

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Allen-Bradley 2198-E1015-ERS / 2198-E1020-ERS / 2198-E2030-ERS Kinetix 5100 200 V-class Servo Drives
Item NO. 2911889
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category AB
Brand ALLEN-BRADLEY
Creation Time 2026-09-30

Allen-Bradley 2198-E1015-ERS / 2198-E1020-ERS / 2198-E2030-ERS Kinetix 5100 200 V-class Servo Drives
Allen-Bradley · 5100Kinetix 5100 200 V-class Servo Drives

Allen-Bradley 2198-E1015-ERS / 2198-E1020-ERS / 2198-E2030-ERS Kinetix 5100 200 V-class Servo Drives

1.5 / 2.0 / 3.0 kWSingle- and three-phase variantsMotor · shunt · STO terminals

Product Description

The Allen-Bradley 2198-E1015-ERS / 2198-E1020-ERS / 2198-E2030-ERS group spans 1.5, 2.0 and 3.0 kW Kinetix 5100 EtherNet/IP indexing servo-drive ratings at 230 V. Each drive combines an axis power stage with dual Ethernet networking, embedded index control, motor feedback, digital I/O, a braking-resistor connection and safe torque-off terminals, while the selected catalog number fixes the usable current and circuit-protection range.

Supply compatibility differs inside 2198-E1015-ERS / 2198-E1020-ERS / 2198-E2030-ERS: the first two can operate from 120/230 V single phase or 230 V three phase, with their output reduced on 120 V; the 3.0 kW 2198-E2030-ERS uses 230 V three-phase input. The line input charges the internal dc bus, the inverter produces U/V/W motor power, the MFB connector returns rotor position, and the shunt terminals divert regenerative energy to a selected resistor when the application requires it.

Technical Specifications

Technical Item 2198-E1015-ERS 2198-E1020-ERS 2198-E2030-ERS
Brand Allen-Bradley Allen-Bradley Allen-Bradley
Product Type Kinetix 5100 servo drive Kinetix 5100 servo drive Kinetix 5100 servo drive
Voltage Class 200 V class 200 V class 200 V class
Rated Output at 230 V 1.5 kW 2.0 kW 3.0 kW
Rated Output at 120 V 0.75 kW 1.0 kW Not applicable
AC Input 120/230 V single phase or 230 V three phase 120/230 V single phase or 230 V three phase 230 V three phase
Recommended Protection — Single Phase 30 A 40 A Not applicable
Recommended Protection — Three Phase 25 A 35 A 50 A
Power Conductor Range 0.20…3.31 mm² (24…12 AWG) 0.20…5.26 mm² (24…10 AWG) 0.20…5.26 mm² (24…10 AWG)
Strip Length 11 mm 13 mm 13 mm
Network Dual EtherNet/IP Dual EtherNet/IP Dual EtherNet/IP
Motor Output U/V/W plus protective earth U/V/W plus protective earth U/V/W plus protective earth
Regeneration Interface External shunt-resistor terminals External shunt-resistor terminals External shunt-resistor terminals
Safety Hardwired safe torque off Hardwired safe torque off Hardwired safe torque off
Feedback MFB motor-feedback port MFB motor-feedback port MFB motor-feedback port
Short-circuit Rating 5000 A rms symmetrical 5000 A rms symmetrical 5000 A rms symmetrical
Operating Temperature 0…50 °C 0…50 °C 0…50 °C
Enclosure IP20 open type IP20 open type IP20 open type

200 V Output Scaling and Phase Selection

2198-E1015-ERS / 2198-E1020-ERS / 2198-E2030-ERS share a 200 V-class motor bus, but the installed input phase determines which rating remains available.

Reduced 120 V ratings

The 1.5 and 2.0 kW models become 0.75 and 1.0 kW drives on 120 V single phase, changing the torque-speed envelope available from the motor.

Full 230 V operation

Both smaller drives deliver their full rating on 230 V, while 2198-E2030-ERS requires 230 V three phase for its 3.0 kW output.

Protection tracks input current

The prescribed branch device rises from 25 A to 50 A across the three-phase ratings and must not be selected solely from motor nameplate current.

Motor, Shunt and Safe Torque-Off Connections

The power and control boundaries of 2198-E1015-ERS / 2198-E1020-ERS / 2198-E2030-ERS are separated across motor, feedback, regeneration and safety terminals.

Power and feedback separation

U/V/W carry switched motor power while the MFB connector carries low-level position and commutation signals on the specified feedback cable.

Regenerative-energy path

During deceleration, rising dc-bus energy can be switched into an external shunt resistor selected for resistance, power and duty cycle.

Torque-removal circuit

The STO inputs remove torque-producing gate commands without serving as a general run command; the safety circuit and normal motion enable remain separate.

Frequently Asked Questions

Why can 2198-E1015-ERS / 2198-E1020-ERS / 2198-E2030-ERS not all use 120 V single phase?

Only the E1 models include the stated 120 V single-phase ratings, and those ratings are reduced. The E2030 catalog number is a 230 V three-phase drive and must be supplied accordingly.

How is the correct breaker chosen for 2198-E1015-ERS / 2198-E1020-ERS / 2198-E2030-ERS?

Start with the exact catalog number and installed input phase, then use the documented branch-protection value. Do not copy the breaker size from another 5100 frame simply because the motor voltages match.

Why can 2198-E1015-ERS / 2198-E1020-ERS / 2198-E2030-ERS trip during deceleration?

The moving load can return more energy than the internal bus can absorb. Review the deceleration profile, shunt-resistor connection, resistance and duty rating before treating the drive as defective.

What cable separation matters for 2198-E1015-ERS / 2198-E1020-ERS / 2198-E2030-ERS?

Keep motor and line-power conductors away from feedback, I/O and Ethernet cabling. Proper shield termination and routing reduce noise entering the low-level feedback and control circuits.

Why can STO remain active on 2198-E1015-ERS / 2198-E1020-ERS / 2198-E2030-ERS after an enable command?

The safe torque-off circuit is independent of the network or indexing enable. Both STO channels, their supply and the configured safety loop must be valid before the power stage can produce torque.

What changes in terminal preparation across 2198-E1015-ERS / 2198-E1020-ERS / 2198-E2030-ERS?

E1015 uses the smaller 24…12 AWG range and 11 mm strip length. E1020 and E2030 accept conductors through 10 AWG and use a 13 mm strip length, so connector preparation is not identical.

Our Advantages

www.mvme.cn

One enquiry can cover multiple automation brands

Moore Automation combines model checking, responsive quotation work, original-product supply and export coordination without scattering the purchasing record.

Clear ownership

One contact follows the request.

Broad catalog reach

Control, motion and safety parts are covered.

Documented order

Model and quantity stay visible.

Practical shipping

Packing follows the selected route.

No related record found