Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>AB>Allen-Bradley 1772-M8 PLC-2 8K Core Memory Module
Allen-Bradley 1772-M8 PLC-2 8K Core Memory Module

Allen-Bradley 1772-M8 PLC-2 8K Core Memory Module Item NO.: 2909768

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Allen-Bradley 1772-M8 PLC-2 8K Core Memory Module
Item NO. 2909768
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category AB
Brand ALLEN-BRADLEY
Creation Time 2026-09-19

Allen-Bradley 1772-M8 PLC-2 8K Core Memory Module

PLC-2 memory component · Bulletin 1772

Allen-Bradley 1772-M8 PLC-2 8K Core Memory Module

An 8K-word core-memory option for supported PLC-2 processor arrangements.

CATALOG1772M8
Identity, role and selection boundary

Product Description

Within a compatible Bulletin 1772 controller arrangement, the 1772-M8 provides a fixed 8K-word core-memory class for the PLC-2 processor.

Program logic shares that capacity with the controller data table, I/O image and other required storage areas. The usable space for instructions therefore depends on the complete memory allocation rather than the catalog capacity alone.

The full 1772-M8 designation separates this fixed-capacity module from the segmented 1772-ME construction and the larger 1772-M16 capacity class.

Essential product data

Technical Specifications

Technical Item 1772-M8
Brand Allen-Bradley
Product Type Core Memory Module
Brand Country United States
Catalog Series Bulletin 1772
Controller Family PLC-2
Memory Technology Core memory
Memory Capacity 8K words
PLC-2 Word Size 16 bits
Memory Areas Data table, user program and message storage
Supported Processor Classes PLC-2/20 and PLC-2/30
Compatible Processor Catalogs 1772-LP1, 1772-LP2 and 1772-LP3
Excluded Processor Catalog 1772-LR
Required Power Supply 1772-P1 Series C
8K-word application boundary

Memory Capacity & Compatibility

Functional focus

Capacity plan

Reserve words for the data table and controller housekeeping before assigning the remainder to the user program.

System relationship

Processor match

Confirm that the installed PLC-2 processor configuration accepts the 8K core-memory module.

Maintenance check

Migration check

A move to a different memory size requires review of the program image and controller hardware, not only a catalog swap.

Protect the memory image

Installation & Integration

Prepare before removal.Secure a usable program backup and document the memory layout before exchanging the module in a legacy controller.

For 1772-M8, installation & integration must be reviewed with the installed controller hardware and saved application rather than treated as an isolated catalog-number change.

  • Remove controller power before hardware work.
  • Seat the module in the designated processor configuration.
  • Verify memory and I/O operation after restoration.
Selection, replacement and commissioning

Frequently Asked Questions

How much application space is actually available in 1772-M8?

The module belongs to the 8K-word capacity class, but the user program does not receive every word. Data-table and controller storage requirements must be subtracted when checking fit.

Can 1772-M8 be replaced by 1772-M16 without reviewing the PLC-2 installation?

Do not treat the larger capacity as a drop-in decision by itself. Confirm processor compatibility, hardware requirements and the saved program image before changing memory type.

What backup is needed before removing 1772-M8?

Save the current program and record the controller's data-table and I/O arrangement. A physical replacement without a recoverable image can turn a simple hardware job into a controller recommissioning task.

Why is the complete 1772-M8 catalog important on a purchase order?

It identifies the 8K core-memory product rather than the segmented 1772-ME or 16K 1772-M16 module. The shared 1772 prefix is not enough to preserve capacity and construction.

What should be checked after installing 1772-M8?

Confirm that the processor recognizes the expected memory and that the restored program fits without memory errors. Then verify I/O image operation and controller status before returning the machine to automatic control.

Is 1772-M8 intended as general storage outside a PLC-2 controller?

No; it is controller memory for a compatible PLC-2 processor arrangement. Its value is tied to the legacy control system's program and operating-data requirements.

Moore Automation

Original Product Assurance

Moore Automation

Identity checks before a quotation leaves

Incoming enquiries are reviewed against the brand and complete catalog number. This matters for legacy products where a single letter or memory-capacity suffix can change system compatibility.

Moore Automation supplies original industrial automation components with a one-year warranty and keeps model clarification, quotation and dispatch communication together.

Complete identityNo shortened catalog codes.
Original productsProduct assurance included.
One-year warrantyCommercial warranty coverage.
Clear handoverDetails follow the order.

No related record found