Product Name Allen-Bradley 1745-LP151 / 1745-LP152 SLC 150 Programmable Controllers
Item NO. 2909805
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category AB
Brand ALLEN-BRADLEY
Creation Time 2026-09-20

Allen-Bradley 1745-LP151 / 1745-LP152 SLC 150 Programmable Controllers

32 I/O BASE · VOLTAGE-SPECIFIC INPUTS

Allen-Bradley 1745-LP151 / 1745-LP152 SLC 150 Programmable Controllers

Two SLC 150 base units separated by AC input voltage class.

TWO INPUT CLASSES150
SLC 150

Variant Overview

Allen-Bradley 1745-LP151 and 1745-LP152 are SLC 150 processor units. Each combines the processor, program memory and 32 local I/O points used by an SLC 150 ladder program.

The input circuits distinguish 1745-LP151 from 1745-LP152: LP151 has twenty 85–132 V AC inputs with a red input cover, while LP152 has twenty 170–265 V AC inputs with a black input cover. Both units provide ten triac outputs and two hard-contact outputs.

Both 1745-LP151 and 1745-LP152 use 1200 words of CMOS RAM and have a typical scan time of 4 ms for a 1000-word program. Their capacitor backup retains memory for approximately two weeks at 30 °C, and the optional lithium battery has a 2–3 year life.

SLC 150 processor unit with labeled terminals indicators ports and compartments
SLC 150 processor-unit hardware callouts.
VERIFIED OPERATING VALUES

Verified Operating Data

Technical Item 1745-LP151 1745-LP152
Brand Allen-Bradley Allen-Bradley
Product Type SLC 150 programmable controller SLC 150 programmable controller
Brand Country United States United States
Supply Voltage 85–132 / 170–265 V AC 85–132 / 170–265 V AC
Onboard I/O 32 points 32 points
Inputs 20 20
Input Voltage 85–132 V AC 170–265 V AC
Input Cover Red Black
Outputs 10 triac + 2 hard contact 10 triac + 2 hard contact
Program Memory 1200 words, CMOS RAM 1200 words, CMOS RAM
Typical Scan 4 ms per 1000 words 4 ms per 1000 words
Internal Relays Up to 177 Up to 177
Timer / Counter / Sequencer Instructions Up to 32 Up to 32
Capacitor Retention About 2 weeks at 30 °C About 2 weeks at 30 °C
Optional Battery 1745-B1, approximately 2–3 years 1745-B1, approximately 2–3 years
Operating Temperature 0–60 °C 0–60 °C
INSTALLATION FEATURES

Removable Terminal and Expansion Connections

Removable field terminals

1745-LP151 and 1745-LP152 use removable input and output terminal blocks with self-lifting pressure plates.

Circuit identification

The hinged terminal covers include write-on areas for identifying external circuits.

Expansion connection

A 20-pin to 10-pin ribbon cable connects an expansion unit or a high-speed input module to the processor.

PROGRAMMING FUNCTIONS

SLC 150 Internal Status Instructions

Three SLC 150-only addresses expose memory, battery and triac-control functions to the ladder program.1745-LP151 / 1745-LP152

1745-LP151 and 1745-LP152 use address 864 for programmable EEPROM auto-load after a detected memory checksum error.

  • Address 865 is ON while the optional battery voltage is normal and turns OFF below the battery threshold.
  • Address 866 is the triac zero-cross turn-on instruction.
  • The zero-cross instruction synchronizes the triac outputs with the AC line.
FIELD QUESTIONS

Selection FAQs

What is the decisive difference between 1745-LP151 / 1745-LP152?+

The input voltage. LP151 uses 85–132 V AC inputs, while LP152 uses 170–265 V AC inputs. The cover colors provide a visual cross-check.

Do 1745-LP151 / 1745-LP152 have the same output arrangement?+

Yes. Each has ten triac outputs and two hard-contact outputs, but the connected loads must still meet the detailed ratings.

How much program memory is available in 1745-LP151 / 1745-LP152?+

Both provide 1200 words of CMOS RAM with a typical scan of 4 ms per 1000 words.

How long can 1745-LP151 / 1745-LP152 retain memory without the optional battery?+

The manual gives approximately two weeks at 30 °C for the internal capacitor, falling to about one week at 60 °C.

Why is the cover color important on 1745-LP151 / 1745-LP152?+

Red identifies the LP151 low input-voltage class and black identifies the LP152 higher input-voltage class. Wiring checks must still confirm the actual catalog number.

What should be recorded before exchanging 1745-LP151 / 1745-LP152?+

Save the program, I/O map, field-voltage identification, output-load list and memory-retention status before the controller is powered down.

MOORE AUTOMATION

Our Advantages

Our Advantages

Legacy controller enquiries handled as configuration work

We compare the complete catalog number and application notes before quoting similar-looking SLC hardware.

Variant awarenessPart-number disciplineFast feedbackProtected delivery
www.mvme.cn

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.