Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>ABB>ABB PM582-ETH 1SAP140200R0270 AC500 Classic CPU
ABB PM582-ETH 1SAP140200R0270 AC500 Classic CPU

ABB PM582-ETH 1SAP140200R0270 AC500 Classic CPU Item NO.: 2928075

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name ABB PM582-ETH 1SAP140200R0270 AC500 Classic CPU
Item NO. 2928075
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category ABB
Brand ABB
Creation Time 2026-10-29

ABB PM582-ETH 1SAP140200R0270 AC500 Classic CPU
ABB · AC500 Classic processing

ABB PM582-ETH 1SAP140200R0270 AC500 Classic CPU

512 kBuser memory
Ethernetintegrated network
SD cardproject media
01

Model Profile

ABB PM582-ETH 1SAP140200R0270 is an AC500 Classic CPU with 512 kB of user memory, integrated Ethernet and two selectable serial interfaces. It executes the controller application while coordinating local I/O, communication modules and the terminal-base connections beneath the CPU.

The communication side of ABB PM582-ETH 1SAP140200R0270 separates Ethernet traffic from the two RS-232/RS-485 paths and the FBP interface. That separation matters when control data, service access and field communication share one cabinet, because each route needs its own address, cabling and commissioning check.

For project continuity, ABB PM582-ETH 1SAP140200R0270 supports SD-card handling and a local display with operating keys. The CPU article, base type, project version, memory use and interface modes should be recorded together so later work starts from the verified station rather than a family-level assumption.

02

Technical Parameters

BrandABB
ModelPM582-ETH 1SAP140200R0270
Product nameAC500 Classic CPU with Ethernet
CountrySwitzerland
Controller familyAC500 Classic
User memory512 kB
Supply24 V DC
EthernetIntegrated
Serial interfaces2 × selectable RS-232/RS-485
FieldBusPlug interfaceIntegrated
Removable mediaSD card supported
Local interfaceLCD display and operating keys
Programming environmentAC500 engineering project
03

Operating Characteristics

ABB PM582-ETH 1SAP140200R0270 combines application execution, local diagnostics and several communication paths. Runtime planning must account for how those tasks share CPU memory and scan resources. These operating decisions should be captured in the project and cabinet record so task loading, memory use and communication ownership can be reviewed without reconstructing the original design intent.

01

Balance application work

Review logic, data handling and communication processing together. A memory figure alone does not show whether the runtime task structure for ABB PM582-ETH 1SAP140200R0270 is appropriate.

02

Separate cyclic and event work

Place time-critical control in defined tasks and keep service or communication work from obscuring scan behavior. Document the final task arrangement with ABB PM582-ETH 1SAP140200R0270.

03

Observe the station under load

Commission the CPU with expected communication and I/O activity present, then review diagnostics and response rather than accepting an unloaded bench test as the final state.

04

System Integration

ABB PM582-ETH 1SAP140200R0270 belongs in an AC500 station whose base, I/O, networks and engineering project describe one consistent hardware path. Integration is complete only when the physical slot, the project hardware object and the connected network service describe the same installed controller.

Confirm the base and modules

Build the hardware tree from the installed terminal base and modules before assigning addresses. This keeps ABB PM582-ETH 1SAP140200R0270 aligned with physical slot ownership.

Define network boundaries

Document which devices use Ethernet, each serial port and the FBP path. Give each interface a clear role and commissioning test.

Preserve the project record

Store the CPU article, engineering version, SD-card procedure and verified communication settings together so the integrated station can be reproduced.

05

Product Help

Q01How should the 512 kB memory of ABB PM582-ETH 1SAP140200R0270 be evaluated for an existing project?
Review compiled program size, data, communication buffers and future margin together. Test the actual task structure on ABB PM582-ETH 1SAP140200R0270; do not treat the nominal memory value as the only acceptance check.
Q02Why can an AC500 project communicate over serial but not Ethernet on ABB PM582-ETH 1SAP140200R0270?
The paths have separate configuration. Check the Ethernet address, peer settings and project download independently of the RS-232/RS-485 setup on ABB PM582-ETH 1SAP140200R0270.
Q03What should be checked before moving an SD card to ABB PM582-ETH 1SAP140200R0270?
Confirm the project targets the exact CPU and station hardware, record the engineering version, and verify the intended transfer procedure. Keep the media identity associated with ABB PM582-ETH 1SAP140200R0270.
Q04How can an intermittent station fault be investigated on ABB PM582-ETH 1SAP140200R0270?
Capture local diagnostic messages and network status before resetting the CPU, then compare them with task and communication loading. This preserves evidence from ABB PM582-ETH 1SAP140200R0270 that a power cycle would remove.
Q05What is the safest way to commission the interfaces on ABB PM582-ETH 1SAP140200R0270?
Test Ethernet, the two serial paths and FBP one at a time, then repeat under normal application load. Record addresses, modes and results against ABB PM582-ETH 1SAP140200R0270.
Q06Which station details are needed when requesting ABB PM582-ETH 1SAP140200R0270?
Provide the complete article, terminal base, project version, connected modules, network roles and current CPU label. Those details distinguish ABB PM582-ETH 1SAP140200R0270 from other AC500 Classic CPUs.
06

About Moore Automation

Moore Automation

https://www.mvme.cn

Moore Automation supports industrial automation enquiries across PLC, DCS, drive, monitoring and instrumentation hardware.

Industrial scopeMultiple automation categories are covered.
Record handlingComplete references support review.
Document coordinationAvailable files can follow the request.
Direct contactA named contact keeps the route clear.
07

Similar Products

HoneywellCC-PAIH01
ICS TriplexT8290C
MotorolaMVME147-011
OmronS82K-00724
Phoenix ContactPLC-V8/FLK14/OUT
ProSoftILX56-PBM
Rockwell Automation1756-IA16
Schneider Electric140ACO02000
Siemens1756-A7
Triconex4355X
TRICONEX3301
WAGO753-666/000-003
Woodward8440-2085
YaskawaSJDE-08ANA-0Y
YokogawaA2FV70D-A411000/HKU
ABB3HAC021346-001
Allen-Bradley1734-IB8
B&RX20AI4632
B&R3IF260.60-1
Bently Nevada1900/65A-00-00-01-00-00
Bosch RexrothDDS02.2-W100-BE12-01-FW
Emerson5X00411G01
FoxboroFBM201D
GEIC200CHS022P
HIMAF2 DO 16 02
HoneywellCC-PAIX02
ICS TriplexT8300C
MotorolaMVME147-012
ProSoftMVI56-DFCM
Rockwell Automation1756-IB16IF
Schneider Electric140ACO13000
Siemens1756-CN2R
Triconex9666X
TRICONEX3301S2
Woodward9902-406
YokogawaA2FVX1-D02010
ABB3HAC021353-001
Allen-Bradley1734-IB8S
B&RX20AI8321
B&R4PP045.0571-062
Bently Nevada1900/65A-00-01-01-00-00
Bosch RexrothDDS03.1-W030-D
EmersonIC695CPE330
FoxboroFBM202
GEIC200CPUE05-GK
HIMAF2 DO 8 01
HoneywellCC-PAOH01
ICS TriplexT8310C
MotorolaMVME147-012A
ProSoftMVI56-MCM
Rockwell Automation1756-IB32
Schneider Electric140AII33000C
Siemens1756-DHRIO
TRICONEX3351
Woodward9904-575
YokogawaA2MDV843-0S1000
ABB3HAC021722-001
Allen-Bradley1734-IE2C
B&RX20AO2622
B&R4PP065.0571-P74
08

Sales Assistance

CompanyMoore Automation
ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.