Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>ABB>ABB PM573-ETH-XC 1SAP330300R0271 AC500-XC CPU
ABB PM573-ETH-XC 1SAP330300R0271 AC500-XC CPU

ABB PM573-ETH-XC 1SAP330300R0271 AC500-XC CPU Item NO.: 2931398

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name ABB PM573-ETH-XC 1SAP330300R0271 AC500-XC CPU
Item NO. 2931398
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category ABB
Brand ABB
Creation Time 2026-11-10

ABB AC500-XC · Extreme Conditions CPU

ABB PM573-ETH-XC 1SAP330300R0271 AC500-XC CPU

Ruggedized 512 kB AC500-XC CPU with Ethernet and two configurable serial interfaces.

01

Product Details

ABB PM573-ETH-XC 1SAP330300R0271 is an AC500-XC CPU for controller installations that require the extended environmental design of the XC family. It provides 512 kB program memory, one Ethernet interface and two configurable RS232/RS485 serial interfaces.

ABB publishes minimum instruction times of 0.06 µs for bit operations, 0.09 µs for word operations and 0.7 µs for floating-point operations. These figures describe processor execution; actual cycle performance also reflects program structure, communications and I/O servicing.

The CPU is powered from 24 V DC and can be expanded centrally with up to ten S500 I/O modules, subject to the catalog limits of 320 digital or 160 analog I/O. Terminal-base selection, communication modules and the environmental installation remain part of the full station design.

02

Specifications Overview

BrandABB
Complete modelPM573-ETH-XC 1SAP330300R0271
Controller familyAC500-XC
Product typeProgrammable logic controller CPU
Program memory512 kB
Bit instruction time0.06 µs
Word instruction time0.09 µs
Floating-point time0.7 µs
Integrated Ethernet1 interface
Serial interfaces2 × RS232/RS485 configurable
Supply voltage24 V DC
Central I/O modulesUp to 10 S500 modules
Central digital I/OUp to 320
Central analog I/OUp to 160
External communication modulesUp to 4
WeightApproximately 0.136 kg
03

XC Station Definition

The XC suffix identifies an environmental platform, but a usable controller still depends on a complete CPU, base and I/O definition.

Retain the XC suffix

Use PM573-ETH-XC with order code 1SAP330300R0271 throughout the record. Removing XC risks selecting a standard-environment variant with a different ordering identity.

Choose the terminal base

Match the CPU to the approved terminal base and planned communication-module count. Record base type because field wiring and expansion capacity depend on it.

Budget the I/O station

Count digital, analog and special-function modules before layout. The ten-module physical limit and total channel limits must both be respected.

04

Extreme-condition Installation Checks

Ruggedized electronics do not remove the need for enclosure, wiring and maintenance controls.

Verify the 24 V source

Measure supply quality at the CPU terminals across start-up and field-load changes. Check polarity, grounding and transient protection appropriate to the site.

Protect communication paths

Document Ethernet and both serial modes, termination and shielding. A configurable RS232/RS485 port can be electrically correct but logically wrong if its mode is restored incorrectly.

Inspect the enclosure system

Confirm temperature, contamination, condensation control and cable sealing for the complete panel. The XC designation applies to the product platform, not to an unfinished enclosure.

05

Product Q&A

06

Enquiry Details

Moore Automation

https://www.mvme.cn/

Moore Automation coordinates AC500-XC requests using the complete ruggedized model and order code. Enquiry notes can retain the CPU identity, terminal-base context, documentation requirement, quotation details and planned delivery route.

  • XC suffix and order-code review
  • Terminal-base context recording
  • Documentation request coordination
  • Quotation and delivery follow-up
07

Recommended Models

  • TRICONEX 3008
  • TRICONEX 3009
  • TRICONEX 3511
  • TRICONEX 3515
  • TRICONEX 3601E
  • TRICONEX 3604E
  • TRICONEX 3607E
  • TRICONEX 3625
  • TRICONEX 3625A
  • TRICONEX 3636R
  • TRICONEX 3700A
  • TRICONEX 3701
  • TRICONEX 3703E
  • TRICONEX 3704E
  • TRICONEX 3805E
  • TRICONEX 3806E
  • TRICONEX 3807
  • TRICONEX 3808E
  • TRICONEX 4119A
  • TRICONEX 4200N
  • TRICONEX 4210
  • TRICONEX 4329
  • TRICONEX 4351B
  • TRICONEX 4409
  • TRICONEX 4509
  • TRICONEX 4609
  • TRICONEX 8312
  • TRICONEX 8310
  • TRICONEX 9563-810
  • TRICONEX 9662-610
  • PHOENIX CONTACT 2700605
  • PHOENIX CONTACT 2700978
  • PHOENIX CONTACT 2700994
  • PHOENIX CONTACT 2701084
  • PHOENIX CONTACT 2701094
  • PHOENIX CONTACT 2701169
  • PHOENIX CONTACT 2701455
  • PHOENIX CONTACT 2701625
  • PHOENIX CONTACT 2702254
  • PHOENIX CONTACT 2702884
  • PHOENIX CONTACT 2702975
  • PHOENIX CONTACT 2703981
  • PHOENIX CONTACT 2866763
  • PHOENIX CONTACT 2866776
  • PHOENIX CONTACT 2866789
  • PHOENIX CONTACT 2866792
  • PHOENIX CONTACT 2866802
  • PHOENIX CONTACT 2866815
  • PHOENIX CONTACT 2866828
  • PHOENIX CONTACT 2866831
  • PHOENIX CONTACT 2902991
  • PHOENIX CONTACT 2903147
  • PHOENIX CONTACT 2903150
  • PHOENIX CONTACT 2903153
  • PHOENIX CONTACT 2904601
  • PHOENIX CONTACT 2904622
  • PHOENIX CONTACT 2904623
  • PHOENIX CONTACT 2904624
  • PHOENIX CONTACT 2961105
  • PHOENIX CONTACT 2966171

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.