Program allocation
The 160 MB user program area and 32 MB code-and-data portion support larger AC500 V3 applications without treating web data, retained values and executable code as one interchangeable figure.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | ABB PM5675-2ETH 1SAP151500R0378 / PM5675-2ETH-XC 1SAP351500R0378 AC500 V3 Processor Modules |
| Item NO. | 2931990 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | ABB |
| Brand | ABB |
| Creation Time | 2026-11-12 |
ABB PM5675-2ETH 1SAP151500R0378 / PM5675-2ETH-XC 1SAP351500R0378 are AC500 V3 processor modules built around a 1 GHz ARM Cortex-A9 control platform. Both versions provide 160 MB of user program memory, 32 MB for dynamically allocated program code and data, an integrated 8 GB flash disk, an LCD and eight operating keys.
Communication on ABB PM5675-2ETH 1SAP151500R0378 / PM5675-2ETH-XC 1SAP351500R0378 is organized through two independent Ethernet interfaces, one configurable RS232/RS485 channel and one CAN interface. The Ethernet pair can be used with switch functionality, while the serial and CAN paths remain separately configured for their assigned field protocols.
The distinction inside ABB PM5675-2ETH 1SAP151500R0378 / PM5675-2ETH-XC 1SAP351500R0378 is the environmental construction and matching terminal-base family. The standard processor is intended for the AC500 environment; the XC processor extends the operating range and must be paired with the corresponding XC base rather than selected by front appearance alone.
| Specification | PM5675-2ETH 1SAP151500R0378 | PM5675-2ETH-XC 1SAP351500R0378 |
|---|---|---|
| Brand | ABB | ABB |
| Product Name | AC500 V3 Processor Module | AC500-XC V3 Processor Module |
| Country | Not specified | Not specified |
| Series | AC500 V3 | AC500-XC V3 |
| Supply voltage | 24 V DC | 24 V DC |
| User program memory | 160 MB | 160 MB |
| Program code and data | 32 MB | 32 MB |
| Integrated flash disk | 8 GB | 8 GB |
| Minimum instruction cycle | 0.002 µs | 0.002 µs |
| Ethernet interfaces | 2 independent ports | 2 independent ports |
| Serial / CAN | 1 × RS232/RS485; 1 × CAN | 1 × RS232/RS485; 1 × CAN |
| Local operation | LCD and 8 keys | LCD and 8 keys |
| Operating environment | Standard AC500 range | XC range, -40 to +70 °C |
| Terminal-base family | TB56xx-2ETH | TB56xx-2ETH-XC |
| Weight | 0.135 kg | 0.138 kg |
The two PM5675 identities share the same application resources; environmental construction does not reduce the controller memory available to the project.
The 160 MB user program area and 32 MB code-and-data portion support larger AC500 V3 applications without treating web data, retained values and executable code as one interchangeable figure.
The 8 GB internal flash disk provides local data capacity alongside the removable memory-card slot. Project archives, recipes and logged data still require an intentional retention plan.
A minimum 0.002 µs instruction figure applies to bit, word and floating-point operations. Task intervals must still be chosen from the complete application load and communication schedule.
Ethernet, serial and CAN resources are native to the PM5675 platform, but each path retains its own electrical and protocol rules.
Two independent Ethernet interfaces can also operate with switch functionality. IP plans and enabled services determine whether the ports serve one logical network or separated plant functions.
The serial channel is selected as RS232 or RS485 and then assigned its ASCII or Modbus RTU behavior. Cabling, framing, node role and termination must agree.
The CAN interface supports CANopen and additional CAN services. A powered connector alone does not establish a valid bus; bitrate, topology, termination and node identity remain part of commissioning.
Keep ABB PM5675-2ETH 1SAP151500R0378 / PM5675-2ETH-XC 1SAP351500R0378 as two complete identities. The XC suffix controls environmental construction and terminal-base choice, so the order numbers must not be shortened to PM5675.
ABB PM5675-2ETH 1SAP151500R0378 / PM5675-2ETH-XC 1SAP351500R0378 belongs to the revision-3 hardware line. Check the Automation Builder and firmware baseline before importing an older project or attempting a downgrade.
For ABB PM5675-2ETH 1SAP151500R0378 / PM5675-2ETH-XC 1SAP351500R0378, use a TB56xx-2ETH base for the standard processor and the corresponding TB56xx-2ETH-XC base for the XC processor. Confirm the printed suffix on both parts.
For ABB PM5675-2ETH 1SAP151500R0378 / PM5675-2ETH-XC 1SAP351500R0378, document both port addresses, protocol assignments and switch setting. Avoid joining two plant segments until duplicate addressing and unintended loops are excluded.
The program area, retained variables, internal flash and optional memory card on ABB PM5675-2ETH 1SAP151500R0378 / PM5675-2ETH-XC 1SAP351500R0378 serve different purposes. Restore the correct archive and retention configuration instead of assuming every file is part of the application download.
Record the LCD state and LED pattern on ABB PM5675-2ETH 1SAP151500R0378 / PM5675-2ETH-XC 1SAP351500R0378 before cycling power. Compare them with the project diagnostics, base supply and communication status so the original condition is not lost.
Moore Automation organizes industrial automation enquiries around complete manufacturer identities, revision records and supporting documentation. This keeps standard and extreme-condition controller requests distinct during quotation and receiving.
Inventory evidence, packing notes and shipment milestones can be coordinated in one commercial record, allowing the requested processor suffix and article number to remain visible throughout the transaction.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found