Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>ABB>ABB PM5630-2ETH 1SAP131000R0378 AC500 Processor Module
ABB PM5630-2ETH 1SAP131000R0378  AC500 Processor Module

ABB PM5630-2ETH 1SAP131000R0378 AC500 Processor Module Item NO.: 2928011

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name ABB PM5630-2ETH 1SAP131000R0378 AC500 Processor Module
Item NO. 2928011
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category ABB
Brand ABB
Creation Time 2026-10-28

ABB PM5630-2ETH 1SAP131000R0378 AC500 Processor Module
PROCESSORAC500Revision 3
ABB · PM5630-2ETH 1SAP131000R0378

ABB PM5630-2ETH  1SAP131000R0378
AC500 Processor Module

01

Product Description

ABB PM5630-2ETH 1SAP131000R0378 is an AC500 processor module that forms the central control unit of an ABB AC500 station. It executes the user application, coordinates the local I/O bus and exchanges controller data through Ethernet, serial and CAN paths.

Mounted on a selected TB56xx-2ETH terminal base, ABB PM5630-2ETH 1SAP131000R0378 receives 24 V DC through the base while the base exposes COM1, CAN, ETH1 and ETH2 to the field wiring. Up to ten digital or analog I/O expansion modules can continue to the right through the local I/O bus, so controller power, communications and I/O remain separate connection paths.

Inside ABB PM5630-2ETH 1SAP131000R0378, the 300 MHz Cortex-A9 processor works with the application, retain and user-data memory areas. The front display, status LEDs and function keys present operating and diagnostic information, while an optional memory card handles application transfer, firmware updates, project source or user files.

ABB PM5630-2ETH 1SAP131000R0378 official PM56xx system layout showing processor, terminal base and interfaces
02

Technical Specifications

Brand ABB
Model + order number PM5630-2ETH 1SAP131000R0378
Product Name AC500 Processor Module with Dual Ethernet
Country Germany
Revision status Revision 3 · Active
System Family AC500
Processor TI ARM Cortex-A9, 32-bit RISC, 300 MHz
Application Memory Up to 9 MB downloadable application; 2 MB program code and data
Retain / Persistent Memory 128 kB retain-persistent area; 128 kB %M area
Supply Connection 24 V DC through a TB56xx-2ETH terminal base and removable 5-pin spring terminal
Current Consumption 110 mA typical for the processor alone; 400 mA maximum typical with communication and I/O modules
Ethernet 2 × 10/100Base-TX RJ45; configurable as a switch or two independent interfaces
COM1 RS-232 / RS-485, 9.6 to 115.2 kbit/s; ASCII and Modbus RTU
CAN Interface 50 kbit/s to 1 Mbit/s; CANopen master, J1939 and CAN synchronization
Mounting / Weight Horizontal or vertical mounting; 135 g without terminal base
03

Communication and Connectivity

ABB PM5630-2ETH 1SAP131000R0378 separates network, serial, CAN and local-I/O traffic so each connection reaches the interface intended for that data path.

ETH1 / ETH2

Two Ethernet paths

The two RJ45 ports can operate as a switched pair or as separately configured interfaces for distinct controller network paths.

COM1 + CAN

Two field-bus routes

COM1 carries ASCII or Modbus RTU over the selected RS-232 or RS-485 electrical mode. The separate CAN terminals carry CANopen, J1939 or CAN-sync traffic with their own bus rate and termination.

I/O BUS

Local expansion data

The right-side I/O bus transfers process values between the processor and as many as ten attached digital or analog expansion modules.

04

Installation Highlights

Install ABB PM5630-2ETH 1SAP131000R0378 by matching the terminal base to the communication-module count, assembling the station without power and commissioning each connection path in sequence.
01

Select the terminal base

Use TB5600-2ETH when no communication-module slot is needed, TB5610-2ETH for one slot or TB5620-2ETH for two slots. Confirm the required connectors before the base is fixed to the DIN rail.

02

Assemble with power isolated

Switch off controller and process voltages, mount the terminal base, seat ABB PM5630-2ETH 1SAP131000R0378, add permitted communication modules and continue the I/O modules to the right without inserting or removing hardware under power.

03

Wire and verify each path

Terminate the 24 V DC supply, Ethernet, COM1 and CAN wiring at the labeled base connections. Restore power, then use the display and LEDs to confirm CPU state, interface activity and diagnostic status before field operation begins.

05

Frequently Asked Questions

Which revision should be specified when replacing an older ABB PM5630-2ETH 1SAP131000R0378?

ABB PM5630-2ETH 1SAP131000R0378 is Revision 3. A project that previously used Revision 2 should be checked against Automation Builder 2.6 or later and firmware 3.6 or later before the Revision 3 processor is introduced.

Which terminal base is correct for ABB PM5630-2ETH 1SAP131000R0378?

ABB PM5630-2ETH 1SAP131000R0378 uses a TB56xx-2ETH base. Choose TB5600-2ETH for no communication-module slot, TB5610-2ETH for one slot, or TB5620-2ETH for two slots; the selected base also carries the power, COM1, CAN and Ethernet terminations.

Can the two Ethernet ports of ABB PM5630-2ETH 1SAP131000R0378 serve separate networks?

ABB PM5630-2ETH 1SAP131000R0378 can configure ETH1 and ETH2 as two independent 10/100Base-TX interfaces or as a switched pair. Independent mode is used when the project assigns different interface settings and network paths to the two ports.

What should be checked when serial or CAN devices do not communicate with ABB PM5630-2ETH 1SAP131000R0378?

For ABB PM5630-2ETH 1SAP131000R0378, confirm that COM1 is configured for the same RS-232 or RS-485 electrical mode as the field device, then verify baud rate and protocol. For CAN, verify bus rate, termination, node addressing and the CANopen, J1939 or CAN-sync configuration selected by the project.

What can the optional memory card do in ABB PM5630-2ETH 1SAP131000R0378?

ABB PM5630-2ETH 1SAP131000R0378 can use an MC5141 card or an MC5102 adapter to transfer an application, update firmware, retain project source material or store user files. The card operation should match the selected transfer or update procedure rather than being removed while data is being written.

What must be isolated before ABB PM5630-2ETH 1SAP131000R0378 is removed from its terminal base?

Before ABB PM5630-2ETH 1SAP131000R0378 is released from the TB56xx-2ETH base, switch off the controller supply and all process voltages connected through communication or I/O wiring. The processor, terminal base and expansion modules are not intended for insertion or removal under power.

06

Our Services

Moore Automation

https://www.mvme.cn

Moore Automation organizes industrial automation enquiries around the exact manufacturer, complete model, revision, quantity and destination. Product records can remain linked with supporting technical documents so commercial and engineering review refer to the same requested hardware.

For multi-brand requests, the service scope can include controllers, I/O, communications, drives and condition-monitoring products while keeping each line item distinct.

Product reviewManufacturer, model and revision retained
Document coordinationAvailable technical records linked to the enquiry
Order continuityQuantity and destination remain attached
Multi-brand scopeControl, I/O, network and monitoring ranges
Moore Automation warehouse service team
07

Recommended Products

Siemens6ES7216-1AG40-0XB0
Rockwell Automation1756-CN2R/B
ABBAI531
Schneider Electric140ACI03000
Siemens6ES7217-1BG40-0XB0
Rockwell Automation1756-EN2TR
ABBAI561
Schneider Electric140ACI04000C
Siemens6ES7288-0AE20-0AA0
Rockwell Automation1756-EN3TR
ABBAI562
Schneider Electric140ACO13000
Siemens6ES7288-0CD10-0AA0
Rockwell Automation1756-ENBT
ABBAI563
Schneider Electric140AII33000C
Siemens6ES7288-0DR10-0AA0
Rockwell Automation1756-IA16
ABBAI815
Schneider Electric140CHS11000
Siemens6ES7288-0ED10-0AA0
Rockwell Automation1756-IB16IF
ABBAI830A
Schneider Electric140CPS11410
Siemens6ES7288-1CR20-0AA0
Rockwell Automation1756-IB32
ABBAI880A
Schneider Electric140CPU42402
Siemens6ES7288-1CR60-0AA0
Rockwell Automation1756-IF16
ABBAO522
Schneider Electric140CPU65150
Siemens6ES7288-2DT16-0AA0
Rockwell Automation1756-L71
ABBAO561
Schneider Electric140CPU67160
Siemens6ES7288-3AM03-0AA0
Rockwell Automation1756-L73
ABBAO562
Schneider Electric140CPU67260
Siemens6ES7288-3AT04-0AA0
Rockwell Automation1756-L74
ABBAO810
Schneider Electric140CRA93100
Siemens6ES7288-3AT08-0AA0
Rockwell Automation1756-L75
ABBCI501-PNIO
Schneider Electric140CRP31200
Siemens6ES7288-3TC04-0AA0
Rockwell Automation1756-L82E
ABBCI502-PNIO
Schneider Electric140CRP93100
Siemens6ES7288-5CM01-2CA0
Rockwell Automation1756-OB16I
ABBCI504-PNIO
Schneider Electric140DA084010
Siemens6ES7288-5DT16-0AA0
Rockwell Automation1756-OB32E
ABBCI506-PNIO
Schneider Electric140DAI54300
08

Contact Information

Discuss the exact product record

Share the full model, revision and requested quantity for review.

CompanyMoore Automation
ManagerLeonia

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.