Two Ethernet paths
The two RJ45 ports can operate as a switched pair or as separately configured interfaces for distinct controller network paths.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | ABB PM5630-2ETH 1SAP131000R0378 AC500 Processor Module |
| Item NO. | 2928011 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | ABB |
| Brand | ABB |
| Creation Time | 2026-10-28 |
ABB PM5630-2ETH 1SAP131000R0378 is an AC500 processor module that forms the central control unit of an ABB AC500 station. It executes the user application, coordinates the local I/O bus and exchanges controller data through Ethernet, serial and CAN paths.
Mounted on a selected TB56xx-2ETH terminal base, ABB PM5630-2ETH 1SAP131000R0378 receives 24 V DC through the base while the base exposes COM1, CAN, ETH1 and ETH2 to the field wiring. Up to ten digital or analog I/O expansion modules can continue to the right through the local I/O bus, so controller power, communications and I/O remain separate connection paths.
Inside ABB PM5630-2ETH 1SAP131000R0378, the 300 MHz Cortex-A9 processor works with the application, retain and user-data memory areas. The front display, status LEDs and function keys present operating and diagnostic information, while an optional memory card handles application transfer, firmware updates, project source or user files.
| Brand | ABB |
|---|---|
| Model + order number | PM5630-2ETH 1SAP131000R0378 |
| Product Name | AC500 Processor Module with Dual Ethernet |
| Country | Germany |
| Revision status | Revision 3 · Active |
| System Family | AC500 |
| Processor | TI ARM Cortex-A9, 32-bit RISC, 300 MHz |
| Application Memory | Up to 9 MB downloadable application; 2 MB program code and data |
| Retain / Persistent Memory | 128 kB retain-persistent area; 128 kB %M area |
| Supply Connection | 24 V DC through a TB56xx-2ETH terminal base and removable 5-pin spring terminal |
| Current Consumption | 110 mA typical for the processor alone; 400 mA maximum typical with communication and I/O modules |
| Ethernet | 2 × 10/100Base-TX RJ45; configurable as a switch or two independent interfaces |
| COM1 | RS-232 / RS-485, 9.6 to 115.2 kbit/s; ASCII and Modbus RTU |
| CAN Interface | 50 kbit/s to 1 Mbit/s; CANopen master, J1939 and CAN synchronization |
| Mounting / Weight | Horizontal or vertical mounting; 135 g without terminal base |
ABB PM5630-2ETH 1SAP131000R0378 separates network, serial, CAN and local-I/O traffic so each connection reaches the interface intended for that data path.
The two RJ45 ports can operate as a switched pair or as separately configured interfaces for distinct controller network paths.
COM1 carries ASCII or Modbus RTU over the selected RS-232 or RS-485 electrical mode. The separate CAN terminals carry CANopen, J1939 or CAN-sync traffic with their own bus rate and termination.
The right-side I/O bus transfers process values between the processor and as many as ten attached digital or analog expansion modules.
Use TB5600-2ETH when no communication-module slot is needed, TB5610-2ETH for one slot or TB5620-2ETH for two slots. Confirm the required connectors before the base is fixed to the DIN rail.
Switch off controller and process voltages, mount the terminal base, seat ABB PM5630-2ETH 1SAP131000R0378, add permitted communication modules and continue the I/O modules to the right without inserting or removing hardware under power.
Terminate the 24 V DC supply, Ethernet, COM1 and CAN wiring at the labeled base connections. Restore power, then use the display and LEDs to confirm CPU state, interface activity and diagnostic status before field operation begins.
ABB PM5630-2ETH 1SAP131000R0378 is Revision 3. A project that previously used Revision 2 should be checked against Automation Builder 2.6 or later and firmware 3.6 or later before the Revision 3 processor is introduced.
ABB PM5630-2ETH 1SAP131000R0378 uses a TB56xx-2ETH base. Choose TB5600-2ETH for no communication-module slot, TB5610-2ETH for one slot, or TB5620-2ETH for two slots; the selected base also carries the power, COM1, CAN and Ethernet terminations.
ABB PM5630-2ETH 1SAP131000R0378 can configure ETH1 and ETH2 as two independent 10/100Base-TX interfaces or as a switched pair. Independent mode is used when the project assigns different interface settings and network paths to the two ports.
For ABB PM5630-2ETH 1SAP131000R0378, confirm that COM1 is configured for the same RS-232 or RS-485 electrical mode as the field device, then verify baud rate and protocol. For CAN, verify bus rate, termination, node addressing and the CANopen, J1939 or CAN-sync configuration selected by the project.
ABB PM5630-2ETH 1SAP131000R0378 can use an MC5141 card or an MC5102 adapter to transfer an application, update firmware, retain project source material or store user files. The card operation should match the selected transfer or update procedure rather than being removed while data is being written.
Before ABB PM5630-2ETH 1SAP131000R0378 is released from the TB56xx-2ETH base, switch off the controller supply and all process voltages connected through communication or I/O wiring. The processor, terminal base and expansion modules are not intended for insertion or removal under power.
Moore Automation organizes industrial automation enquiries around the exact manufacturer, complete model, revision, quantity and destination. Product records can remain linked with supporting technical documents so commercial and engineering review refer to the same requested hardware.
For multi-brand requests, the service scope can include controllers, I/O, communications, drives and condition-monitoring products while keeping each line item distinct.