Map the controller side
Record the paired NIS21, INFI-Net loop identity and the nodes expected through ABB IET800. This establishes whether a missing point begins on the control network or after the transfer module.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | ABB IET800 INFI-Net to Ethernet Transfer Module |
| Item NO. | 2931394 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | ABB |
| Brand | ABB |
| Creation Time | 2026-11-10 |
ABB Symphony Plus · Communications Gateway
Symphony communications interface that transfers INFI-Net data to Ethernet-based engineering and operations clients.
ABB IET800 is an INFI-Net to Ethernet transfer module used in Symphony communications architecture. It acts as an Ethernet CIU, presenting INFI-Net information to supported engineering, operations and OPC environments while retaining the controller-network context.
The module is built around a 32-bit ColdFire MCF5475 processor running at 256 MHz, with 64 MB DRAM and 2 MB NVRAM. Its CH0 interface provides 10/100 Mbps Ethernet over RJ45; CH1 is identified as reserved in the ABB roadmap material, so it should not be planned as a second active plant port.
Gateway performance and client capacity depend on a disciplined network record. ABB lists a 30,000-tag database, more than 1,500 exception reports per second and up to 10 Composer clients, but commissioning still requires correct NIS21 pairing, IP planning, security mode and host compatibility.
IET800 commissioning is clearer when INFI-Net, gateway and Ethernet responsibilities are separated before any address is changed.
Record the paired NIS21, INFI-Net loop identity and the nodes expected through ABB IET800. This establishes whether a missing point begins on the control network or after the transfer module.
Assign CH0 addressing, switch port, VLAN and routing according to the plant design. CH1 is reserved in the published description and should not be treated as an available redundant port.
List Composer, operations and OPC consumers before cutover. Keeping the client count and tag demand visible helps distinguish gateway capacity from an individual workstation problem.
The gateway should be introduced with the same change discipline as a control-system network device.
Confirm the supported Composer, Symphony Plus Operations, 800xA or Harmony OPC release before connecting ABB IET800. Software compatibility must be resolved before point testing.
Document whether the project uses basic Twofish protection or the advanced TLS/SSL mode described by ABB. Certificates, keys and host settings must follow the chosen mode consistently.
Test controller-to-client values, timestamps, exception updates and engineering writes in a controlled sequence. A directional test reveals whether addressing, permissions or source mapping caused the mismatch.
ABB IET800 can have a healthy CH0 Ethernet path while its NIS21 pairing, INFI-Net node mapping or client database is incomplete; check the control-network side separately from IP reachability.
For ABB IET800, record the current address, switch port, subnet, routes and every dependent client before changing CH0, then test engineering and operations connections one by one.
ABB IET800 publishes CH0 as the 10/100 Mbps RJ45 connection and identifies CH1 as reserved, so CH1 should not be designed as an active redundant Ethernet interface.
For ABB IET800, stale values can follow source-node loss, exception-report interruption, overloaded client polling or incorrect point mapping; compare live INFI-Net status with client timestamps.
Before replacing ABB IET800, preserve the module and NIS21 identities, IP settings, security mode, database configuration, supported host versions and switch-port details.
For ABB IET800, inventory the intended Composer and server connections, point count and update demand, then validate them against the published 30,000-tag and up-to-10-Composer-client limits.
Moore Automation handles legacy communications enquiries by preserving the installed-system context. For IET800 requests, the coordination record can include the gateway model, paired network module, software environment, available documentation and delivery priorities.