Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>ABB>ABB CI871A 3BSE092693R1 | AC 800M PROFINET IO Communication Interface Module
ABB CI871A 3BSE092693R1 | AC 800M PROFINET IO Communication Interface Module

ABB CI871A 3BSE092693R1 | AC 800M PROFINET IO Communication Interface Module Item NO.: 2925409

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name ABB CI871A 3BSE092693R1 | AC 800M PROFINET IO Communication Interface Module
Item NO. 2925409
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category ABB
Brand ABB
Creation Time 2026-10-20

ABB CI871A 3BSE092693R1 | AC 800M PROFINET IO Communication Interface | Moore Automation
ABB CI871A 3BSE092693R1

ABB · AC 800M COMMUNICATION INTERFACE

ABB CI871A 3BSE092693R1 | AC 800M PROFINET IO Communication Interface Module

PROFINET IO · 10/100 MBIT/S · REDUNDANT MODULE SUPPORT

01

Product Overview

ABB CI871A 3BSE092693R1 is an AC 800M communication interface that connects PROFINET IO devices to the System 800xA control environment through Ethernet. It acts as the PROFINET IO master, while the TP867 baseplate provides the physical module position and the CEX-Bus carries the interface logic and supply distribution.

The Ethernet path uses the CH1 RJ-45 connector on the TP867 baseplate for the PROFINET IO network. ABB CI871A 3BSE092693R1 receives its required voltage from the +24 V supply through the CEX-Bus DC/DC converter, so the communication interface and its baseplate remain one installed hardware path rather than two independent field devices.

Within a controller station, ABB CI871A 3BSE092693R1 supports module redundancy and hot swap. The interface is intended for the stated System 800xA software releases and operates in a 0 to +55 °C environment with IP20 protection and 5 to 95 percent non-condensing humidity.

02

Technical Specifications

Technical Item Value
Model ABB CI871A 3BSE092693R1
Brand ABB
Product origin Switzerland / ABB supply chain
Product type AC 800M PROFINET IO communication interface
Article number 3BSE092693R1
Protocol PROFINET IO
Role Master
Transmission speed 10/100 Mbit/s
Line redundancy No
Module redundancy Yes
Hot swap Yes
CEX-Bus capacity Up to 12 units
Connector RJ-45 female, 8-pin
Typical 24 V consumption 160 mA
Operating temperature 0 to +55 °C
Storage temperature −40 to +70 °C
Protection class IP20
Relative humidity 5 to 95 %, non-condensing
Dimensions 59 × 185 × 127.5 mm
Weight including base 700 g
03

Communication and Connectivity

ABB CI871A 3BSE092693R1 moves controller data to PROFINET IO devices through the Ethernet interface.

01

PROFINET master role

The CI871A is the master on the PROFINET IO network and coordinates the connected IO device communication.

02

RJ-45 network path

The CH1 RJ-45 connector on the TP867 baseplate is the physical Ethernet connection used for PROFINET IO.

03

10/100 Mbit/s link

The interface supports 10/100 Mbit/s transmission, matching the network segment and switch used with the controller station.

04

System Integration

ABB CI871A 3BSE092693R1 sits on the AC 800M CEX-Bus and joins the controller, baseplate, Ethernet switch and PROFINET IO field devices.

01

CEX-Bus position

The expansion unit contains the CEX-Bus logic, communication unit and DC/DC converter that feeds the interface.

02

Redundant module option

Module redundancy is supported, while line redundancy is not; the network topology must therefore reflect the selected redundancy method.

03

Baseplate and controller

The CI871A works with the TP867 baseplate and is intended for the stated AC 800M controller environment rather than a standalone Ethernet panel.

05

Frequently Asked Questions

What network does ABB CI871A 3BSE092693R1 connect to?

ABB CI871A 3BSE092693R1 connects AC 800M to PROFINET IO devices through the Ethernet network.

Which connector is used by ABB CI871A 3BSE092693R1?

ABB CI871A 3BSE092693R1 uses the CH1 RJ-45 connector on the TP867 baseplate for the PROFINET IO link.

Is ABB CI871A 3BSE092693R1 a PROFINET master or slave?

ABB CI871A 3BSE092693R1 is the PROFINET IO master in the AC 800M communication arrangement.

How is ABB CI871A 3BSE092693R1 powered?

ABB CI871A 3BSE092693R1 receives the required voltage through the CEX-Bus from the +24 V supply and its DC/DC converter.

Can ABB CI871A 3BSE092693R1 support hot swap?

Yes. ABB CI871A 3BSE092693R1 is listed with hot-swap support in the AC 800M communication interface family.

What temperature range applies to ABB CI871A 3BSE092693R1?

ABB CI871A 3BSE092693R1 is specified for 0 to +55 °C operation and −40 to +70 °C storage.

06

Company Profile

Moore Automation

https://www.mvme.cn/

Moore Automation supports ABB communication articles with exact article-number checking and a clear record of the controller, baseplate and protocol environment.

For ABB CI871A 3BSE092693R1, the requested article remains connected to its PROFINET, CEX-Bus and AC 800M details during quotation and dispatch.

Protocol reviewPROFINET and AC 800M details stay with the article record.
Original article recordABB CI871A 3BSE092693R1 remains visible before quotation.
Dispatch tracePacking and shipment details stay linked to the enquiry.
www.mvme.cn

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.