Start with the exact row
Match ACS880-01-169A-3 and order number 3AUA0000108027 before using any current value. Adjacent R7 rows cover different power levels and cannot substitute for the 169A-3 line.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | ABB ACS880-01-169A-3 3AUA0000108027 Wall-mounted Drive |
| Item NO. | 2931393 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | ABB |
| Brand | ABB |
| Creation Time | 2026-11-10 |
ABB Drives · ACS880 Single Drive
Complete 400 V ACS880 wall-mounted drive identity for a 169 A nominal output and 90 kW IEC motor rating.
ABB ACS880-01-169A-3 3AUA0000108027 is a wall-mounted ACS880 single drive in the 400 V class. ABB's IEC ratings table places this exact type code in frame R7 with 169 A nominal output current and a 90 kW nominal motor rating, so the type code and order number should remain together in purchasing records.
The rating line separates nominal, light-duty and heavy-duty service. For this model, the published values are 169 A at nominal duty, 161 A at light duty and 145 A at heavy duty; the corresponding motor powers are 90 kW, 90 kW and 75 kW. Those duty columns are not interchangeable selection shortcuts.
Before replacement, compare the existing nameplate, supply class, cabinet cooling route, cable interfaces and the parameter backup. The R7 mechanical frame defines the installation envelope, while the saved configuration and application-specific options determine how the replacement returns to service.
The ACS880-01-169A-3 3AUA0000108027 rating must be read as a set of operating columns, not as one universal current limit.
Match ACS880-01-169A-3 and order number 3AUA0000108027 before using any current value. Adjacent R7 rows cover different power levels and cannot substitute for the 169A-3 line.
Use nominal, light-duty or heavy-duty data according to the load cycle and overload demand. The heavy-duty column intentionally reduces the continuous current and motor-power figure.
Record frame R7 with the electrical rating. It governs mounting, cooling clearances and service-part selection even when another ACS880 has a visually similar enclosure.
A successful drive exchange depends on the installation record as well as the catalog type code.
Photograph the full drive label and verify ACS880-01-169A-3 3AUA0000108027 before removal. Retain option codes and serial information separately from the base order number.
Back up parameters and note the control source, motor data, fieldbus settings and safety circuit state. A correct hardware rating does not recreate the operating configuration automatically.
Inspect airflow, contamination, ambient conditions, cable routing and protective devices before energizing. Correcting a blocked cooling path protects the new R7 unit from repeating the earlier failure.
For ABB ACS880-01-169A-3 3AUA0000108027, compare the full type code, order number, voltage class, R7 frame, option codes and the existing parameter backup; do not select from 90 kW alone.
ABB ACS880-01-169A-3 3AUA0000108027 uses separate nominal, light-duty and heavy-duty values. Select the column that matches the actual overload cycle, with heavy duty published at 145 A and 75 kW.
Before removing ABB ACS880-01-169A-3 3AUA0000108027, save parameters and document motor data, I/O assignments, fieldbus addressing, safety settings and installed options.
ABB ACS880-01-169A-3 3AUA0000108027 can overheat if filters, heatsink airways, cabinet extraction or clearance conditions remain restricted, even when the replacement type code is correct.
ABB ACS880-01-169A-3 3AUA0000108027 should not be returned to production from defaults without rebuilding and validating the application, motor, feedback, communication and safety configuration.
Before powering ABB ACS880-01-169A-3 3AUA0000108027, verify supply isolation, protective devices, grounding, cable terminations, motor insulation condition, fan path and the approved commissioning plan.
Moore Automation coordinates drive enquiries around exact ABB type codes, order numbers and application records. For this ACS880 selection, the team can align the requested hardware identity with documentation, quotation details, packing requirements and shipment tracking.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.