Power conversion path
ABB ACS550-01-012A-4 converts fixed-frequency three-phase input into a controlled motor waveform; line protection, motor cable and earthing are sized for the exact current and frame execution.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | ABB ACS550-01-012A-4 General Purpose Drive |
| Item NO. | 2931444 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | ABB |
| Brand | ABB |
| Creation Time | 2026-11-10 |
ABB Drives · ACS550 low-voltage platform
An exact ABB drive record for 380–480 V three-phase motor control.
ABB ACS550-01-012A-4 is an ABB wall-mounted low-voltage AC drive in the ACS550 family. It accepts a three-phase 380–480 V supply, rectify it to the internal DC link and synthesize a variable-frequency three-phase output for controlling an AC motor.
Power for ABB ACS550-01-012A-4 enters through the line terminals, passes through the rectifier and DC-link stage, and leaves through the motor terminals while protective earth and control wiring remain separate paths. The complete order code fixes the current class, frame execution and voltage class.
For installation, ABB ACS550-01-012A-4 uses the documented frame frame execution. Cable conductor range, terminal torque, cooling clearance and upstream protection are selected from the installed frame; commissioning then confirms motor data, rotation direction, control source and protective functions before the driven machine is released.
| Technical item | Specification |
|---|---|
| Brand | ABB |
| Product name | ACS550 wall-mounted low-voltage AC drive |
| Drive family | ACS550 |
| Voltage class | 380–480 V AC, three-phase |
| Input frequency | 48–63 Hz |
| Motor output | Three-phase variable voltage and frequency |
| Control interface | Local panel and control terminals |
| Installation environment | Indoor electrical enclosure / wall mounting |
| Voltage class | 380–480 V AC |
| Rated current | 12 A class |
| Control role | Variable-speed induction-motor control |
| Mounting | Wall mounted |
| Enclosure family | ACS550-01 |
| Input | Three-phase AC |
| Motor output | Three-phase variable voltage and frequency |
| Local interface | Control panel connection |
| Ambient basis | 40 °C rating; derate above stated limit |
| Country | Finland |
The operating behavior of ABB ACS550-01-012A-4 is defined by the relationship between the line supply, DC-link conversion, motor output and configured control source.
ABB ACS550-01-012A-4 converts fixed-frequency three-phase input into a controlled motor waveform; line protection, motor cable and earthing are sized for the exact current and frame execution.
Start, stop and reference commands can be assigned to the local panel or control terminals, while status and fault information report whether the requested motor command has been accepted.
ABB ACS550-01-012A-4 separates nominal, light-duty and heavy-duty operation so current demand, motor power and overload behavior are matched to the mechanical load rather than chosen from kW alone.
Commissioning ABB ACS550-01-012A-4 requires the correct frame-specific wiring work and an ordered verification sequence; the numerical ratings are applied to actual conductors, load and protection.
Isolate the line supply, wait for the DC link to discharge and verify zero voltage before opening ABB ACS550-01-012A-4. Record the existing control source, motor data and cable positions.
Use the documented conductor range and terminal torque for the installed frame. Keep line, motor, control and protective-earth conductors in their assigned routes, with shield termination and cooling clearances intact.
Enter the motor nameplate data, check direction uncoupled where possible, prove start/stop and reference selection, then observe current and fault status under a controlled load before normal service.
ABB ACS550-01-012A-4 should be checked for charged control power, cleared faults, the selected local or remote command source, active interlocks and a valid speed reference before motor wiring is disturbed.
ABB ACS550-01-012A-4 selection must also match motor current, acceleration time and load torque. Confirm entered motor data, mechanical freedom and the applicable nominal or heavy-duty current rating.
For ABB ACS550-01-012A-4, isolate all line and external control supplies, wait the prescribed DC-link discharge interval and measure the DC terminals before touching power conductors.
If ABB ACS550-01-012A-4 runs correctly but rotation is reversed, verify the commanded direction and motor phase sequence. Correct the documented connection only while the drive is isolated and discharged.
ABB ACS550-01-012A-4 uses frame-dependent conductor sizes and terminal hardware. Applying a torque from another frame can leave a high-resistance joint or damage the terminal.
Record the complete ABB ACS550-01-012A-4 order code, frame, motor nameplate values, control source, cable sizes, protection device and parameter backup so the restored drive can be checked against the installed machine.
Moore Automation keeps product photographs, requested quantity, destination and exact order number attached to the same customer enquiry.
The complete manufacturer, model, requested quantity and destination remain attached to one record for consistent review.
Send the complete model and requested quantity.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found