ABB 3HAC058993-003 / 3HAC058993-004 identify NTMP01 and NTRL02B module executions in the ABB S800 I/O family. Their service role is on the field-interface side, where a controller command or module state is connected to the documented relay/output circuit.
01
Product Information
ABB 3HAC058993-003 / 3HAC058993-004 identify NTMP01 and NTRL02B module executions in the ABB S800 I/O family. Their service role is on the field-interface side, where a controller command or module state is connected to the documented relay/output circuit.
For ABB 3HAC058993-003 / 3HAC058993-004, the correct record follows the installed terminal arrangement, relay/output assignment and controller tag. The two ordering numbers remain separate because the field circuit and module function are not established by appearance alone.
During replacement of ABB 3HAC058993-003 / 3HAC058993-004, field power is isolated, the relay/output conductors are labeled and the commanded action is tested after the station has returned to a controlled state.
02
Technical Data
TECHNICAL ITEM
3HAC058993-003
3HAC058993-004
BRAND
ABB
PRODUCT NAME
NTMP01 / NTRL02B S800 relay and interface modules
COUNTRY
Sweden
PRODUCT TYPE
NTMP01 / NTRL02B relay/output modules
I/O FAMILY
ABB S800
PRIMARY ROLE
Field relay/output interface
ORDERING RECORDS
3HAC058993-003; 3HAC058993-004
SIGNAL DIRECTION
Controller command to field circuit
STATION INTERFACE
Terminal unit and ModuleBus
SELECTION BASIS
Relay/output assignment
WIRING CONCERN
Contact, common and load conductors
REMOVAL CONDITION
Field power isolated
COMMISSIONING CHECK
Commanded action and feedback
SERVICE SEPARATION
Each article retained separately
03
Product Functions
ABB 3HAC058993-003 / 3HAC058993-004 provide the documented relay/output connection between S800 controller data and the field circuit.
01
Command path
The controller output state reaches the selected relay/output channel through the station interface.
02
Field-circuit separation
Contact and common conductors remain associated with the installed load circuit.
03
Action confirmation
The final check uses the commanded state and the actual field response, not only a module LED.
04
Safety and Compliance
The important protection practice for ABB 3HAC058993-003 / 3HAC058993-004 is controlled isolation and verification of the external field circuit.
01
Isolate the load
Remove field energy before releasing relay/output conductors.
02
Check contact identity
Confirm the contact and common labels against the wiring record before refitting.
03
Controlled energization
Restore power in a controlled state and verify the expected action before normal operation.
05
Product Questions
01
What must be isolated before replacing ABB 3HAC058993-003 for ABB 3HAC058993-003 / 3HAC058993-004?
For ABB 3HAC058993-003 / 3HAC058993-004, for ABB 3HAC058993-003, isolate the external field circuit and verify the contact/common conductors before removal.
02
How are ABB 3HAC058993-003 and ABB 3HAC058993-004 kept separate for ABB 3HAC058993-003 / 3HAC058993-004?
For ABB 3HAC058993-003 / 3HAC058993-004, keep ABB 3HAC058993-003 and ABB 3HAC058993-004 as separate NTMP01 and NTRL02B records matched to their installed relay/output assignments.
03
Why is an LED alone not enough after ABB 3HAC058993-004 is installed for ABB 3HAC058993-003 / 3HAC058993-004?
For ABB 3HAC058993-003 / 3HAC058993-004, aBB 3HAC058993-004 must be checked by both its module indication and the actual commanded field response.
04
What should be checked if the load does not respond to ABB 3HAC058993-003 for ABB 3HAC058993-003 / 3HAC058993-004?
For ABB 3HAC058993-003 / 3HAC058993-004, check the contact/common wiring, external load supply and controller command path for ABB 3HAC058993-003.
05
How should the relay record be documented for ABB 3HAC058993-003 / ABB 3HAC058993-004 for ABB 3HAC058993-003 / 3HAC058993-004?
For ABB 3HAC058993-003 / 3HAC058993-004, record the complete model, terminal position, load circuit and controller tag for ABB 3HAC058993-003 / ABB 3HAC058993-004.
06
Can a similar S800 output module replace ABB 3HAC058993-004 for ABB 3HAC058993-003 / 3HAC058993-004?
For ABB 3HAC058993-003 / 3HAC058993-004, not without confirming the NTRL02B record, terminal arrangement and field-circuit assignment for ABB 3HAC058993-004.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found